Retrofit Measures for Ducts

Here you will find the data for Ducts measures available in the National Residential Efficiency Measures Database. Each measure consists of a before-component, an after-component, and the estimated cost to implement the measure. The measures are listed alphabetically based upon the name of the before-component. Where multiple costs are indicated they must be combined to obtain total measure cost (e.g., fixed ($) and normalized ($/sf) costs).

Cost Drivers

There are many factors that influence the ultimate cost of Ducts measures. The application of the average measure costs displayed below to any particular home is discouraged. Examples of the kinds of issues that can influence the cost of Ducts measures include:
  • Prevailing local wages
  • Drive time
  • Local code requirements
  • Attic height
  • Roof slope
  • Access
  • Presence/condition/type of existing insulation
  • Existing construction and materials
  • Moisture issues present
  • Presence of hazardous materials
  • Nature/size of leaks
  • Crawlspace height

Viewing 125 Ducts Measure(s) of 125

Seal Ducts (Total Leakage):

Before-Component After-Component Cost

10% Leakage, R-4

Properties:

  • Insulation Nominal R-Value: 4.0 h-ft^2-R/Btu
  • Total Leakage: 0.1

Lifetime:

  • 999 Years
 

7.5% Leakage, R-4

Properties:

  • Insulation Nominal R-Value: 4.0 h-ft^2-R/Btu
  • Total Leakage: 0.075

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface0.05 - 0.150.1

Install Uninsulated Ducts:

Before-Component After-Component Cost

10% Leakage, R-4

Properties:

  • Insulation Nominal R-Value: 4.0 h-ft^2-R/Btu
  • Total Leakage: 0.1

Lifetime:

  • 999 Years
 

None

Properties:

  • Insulation Nominal R-Value: h-ft^2-R/Btu
  • Total Leakage:

Lifetime:

  • Years
 

Measure Cost

UnitsRangeAverage
N/A0 - 00

Seal Ducts (Total Leakage):

Before-Component After-Component Cost

10% Leakage, R-6

Properties:

  • Insulation Nominal R-Value: 6.0 h-ft^2-R/Btu
  • Total Leakage: 0.1

Performance Standards:

  • Meets IECC 2009
  • Meets IECC 2012

Lifetime:

  • 999 Years
 

7.5% Leakage, R-6

Properties:

  • Insulation Nominal R-Value: 6.0 h-ft^2-R/Btu
  • Total Leakage: 0.075

Performance Standards:

  • Meets IECC 2009
  • Meets IECC 2012

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface0.05 - 0.150.1

Install Uninsulated Ducts:

Before-Component After-Component Cost

10% Leakage, R-6

Properties:

  • Insulation Nominal R-Value: 6.0 h-ft^2-R/Btu
  • Total Leakage: 0.1

Performance Standards:

  • Meets IECC 2012
  • Meets IECC 2009

Lifetime:

  • 999 Years
 

None

Properties:

  • Insulation Nominal R-Value: h-ft^2-R/Btu
  • Total Leakage:

Lifetime:

  • Years
 

Measure Cost

UnitsRangeAverage
N/A0 - 00

Seal Ducts (Total Leakage):

Before-Component After-Component Cost

10% Leakage, R-8

Properties:

  • Insulation Nominal R-Value: 8.0 h-ft^2-R/Btu
  • Total Leakage: 0.1

Performance Standards:

  • Exceeds IECC 2009
  • Exceeds IECC 2012

Lifetime:

  • 999 Years
 

7.5% Leakage, R-8

Properties:

  • Insulation Nominal R-Value: 8.0 h-ft^2-R/Btu
  • Total Leakage: 0.075

Performance Standards:

  • Exceeds IECC 2012
  • Exceeds IECC 2009

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface0.05 - 0.150.1

Install Uninsulated Ducts:

Before-Component After-Component Cost

10% Leakage, R-8

Properties:

  • Insulation Nominal R-Value: 8.0 h-ft^2-R/Btu
  • Total Leakage: 0.1

Performance Standards:

  • Exceeds IECC 2009
  • Exceeds IECC 2012

Lifetime:

  • 999 Years
 

None

Properties:

  • Insulation Nominal R-Value: h-ft^2-R/Btu
  • Total Leakage:

Lifetime:

  • Years
 

Measure Cost

UnitsRangeAverage
N/A0 - 00

Seal Ducts:

Before-Component After-Component Cost

10% Leakage, Uninsulated

Properties:

  • Insulation Nominal R-Value: 0.0 h-ft^2-R/Btu
  • Total Leakage: 0.1

Lifetime:

  • 999 Years
 

10% Leakage, R-4

Properties:

  • Insulation Nominal R-Value: 4.0 h-ft^2-R/Btu
  • Total Leakage: 0.1

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface0.83 - 1.61.2

Seal Ducts:

Before-Component After-Component Cost

10% Leakage, Uninsulated

Properties:

  • Insulation Nominal R-Value: 0.0 h-ft^2-R/Btu
  • Total Leakage: 0.1

Lifetime:

  • 999 Years
 

10% Leakage, R-6

Properties:

  • Insulation Nominal R-Value: 6.0 h-ft^2-R/Btu
  • Total Leakage: 0.1

Performance Standards:

  • Meets IECC 2012
  • Meets IECC 2009

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface0.89 - 1.81.3

Seal Ducts:

Before-Component After-Component Cost

10% Leakage, Uninsulated

Properties:

  • Insulation Nominal R-Value: 0.0 h-ft^2-R/Btu
  • Total Leakage: 0.1

Lifetime:

  • 999 Years
 

10% Leakage, R-8

Properties:

  • Insulation Nominal R-Value: 8.0 h-ft^2-R/Btu
  • Total Leakage: 0.1

Performance Standards:

  • Exceeds IECC 2009
  • Exceeds IECC 2012

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface0.95 - 1.91.4

Seal and Insulate Ducts (Total Leakage):

Before-Component After-Component Cost

10% Leakage, Uninsulated

Properties:

  • Insulation Nominal R-Value: 0.0 h-ft^2-R/Btu
  • Total Leakage: 0.1

Lifetime:

  • 999 Years
 

7.5% Leakage, R-4

Properties:

  • Insulation Nominal R-Value: 4.0 h-ft^2-R/Btu
  • Total Leakage: 0.075

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface0.8 - 1.81.3

Seal and Insulate Ducts (Total Leakage):

Before-Component After-Component Cost

10% Leakage, Uninsulated

Properties:

  • Insulation Nominal R-Value: 0.0 h-ft^2-R/Btu
  • Total Leakage: 0.1

Lifetime:

  • 999 Years
 

7.5% Leakage, R-6

Properties:

  • Insulation Nominal R-Value: 6.0 h-ft^2-R/Btu
  • Total Leakage: 0.075

Performance Standards:

  • Meets IECC 2009
  • Meets IECC 2012

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface0.86 - 1.91.4

Seal and Insulate Ducts (Total Leakage):

Before-Component After-Component Cost

10% Leakage, Uninsulated

Properties:

  • Insulation Nominal R-Value: 0.0 h-ft^2-R/Btu
  • Total Leakage: 0.1

Lifetime:

  • 999 Years
 

7.5% Leakage, R-8

Properties:

  • Insulation Nominal R-Value: 8.0 h-ft^2-R/Btu
  • Total Leakage: 0.075

Performance Standards:

  • Exceeds IECC 2012
  • Exceeds IECC 2009

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface0.91 - 2.11.5

Seal Ducts (Total Leakage):

Before-Component After-Component Cost

10% Leakage, Uninsulated

Properties:

  • Insulation Nominal R-Value: 0.0 h-ft^2-R/Btu
  • Total Leakage: 0.1

Lifetime:

  • 999 Years
 

7.5% Leakage, Uninsulated

Properties:

  • Insulation Nominal R-Value: 0.0 h-ft^2-R/Btu
  • Total Leakage: 0.075

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface0.05 - 0.150.1

Install Uninsulated Ducts:

Before-Component After-Component Cost

10% Leakage, Uninsulated

Properties:

  • Insulation Nominal R-Value: 0.0 h-ft^2-R/Btu
  • Total Leakage: 0.1

Lifetime:

  • 999 Years
 

None

Properties:

  • Insulation Nominal R-Value: h-ft^2-R/Btu
  • Total Leakage:

Lifetime:

  • Years
 

Measure Cost

UnitsRangeAverage
N/A0 - 00

Seal Ducts (Total Leakage):

Before-Component After-Component Cost

15% Leakage, R-4

Properties:

  • Insulation Nominal R-Value: 4.0 h-ft^2-R/Btu
  • Total Leakage: 0.15

Lifetime:

  • 999 Years
 

10% Leakage, R-4

Properties:

  • Insulation Nominal R-Value: 4.0 h-ft^2-R/Btu
  • Total Leakage: 0.1

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface0.1 - 0.290.2

Seal Ducts (Total Leakage):

Before-Component After-Component Cost

15% Leakage, R-4

Properties:

  • Insulation Nominal R-Value: 4.0 h-ft^2-R/Btu
  • Total Leakage: 0.15

Lifetime:

  • 999 Years
 

7.5% Leakage, R-4

Properties:

  • Insulation Nominal R-Value: 4.0 h-ft^2-R/Btu
  • Total Leakage: 0.075

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface0.15 - 0.440.3

Install Uninsulated Ducts:

Before-Component After-Component Cost

15% Leakage, R-4

Properties:

  • Insulation Nominal R-Value: 4.0 h-ft^2-R/Btu
  • Total Leakage: 0.15

Lifetime:

  • 999 Years
 

None

Properties:

  • Insulation Nominal R-Value: h-ft^2-R/Btu
  • Total Leakage:

Lifetime:

  • Years
 

Measure Cost

UnitsRangeAverage
N/A0 - 00

Seal Ducts (Total Leakage):

Before-Component After-Component Cost

15% Leakage, R-6

Properties:

  • Insulation Nominal R-Value: 6.0 h-ft^2-R/Btu
  • Total Leakage: 0.15

Performance Standards:

  • Meets IECC 2009
  • Meets IECC 2012

Lifetime:

  • 999 Years
 

10% Leakage, R-6

Properties:

  • Insulation Nominal R-Value: 6.0 h-ft^2-R/Btu
  • Total Leakage: 0.1

Performance Standards:

  • Meets IECC 2012
  • Meets IECC 2009

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface0.1 - 0.290.2

Seal Ducts (Total Leakage):

Before-Component After-Component Cost

15% Leakage, R-6

Properties:

  • Insulation Nominal R-Value: 6.0 h-ft^2-R/Btu
  • Total Leakage: 0.15

Performance Standards:

  • Meets IECC 2009
  • Meets IECC 2012

Lifetime:

  • 999 Years
 

7.5% Leakage, R-6

Properties:

  • Insulation Nominal R-Value: 6.0 h-ft^2-R/Btu
  • Total Leakage: 0.075

Performance Standards:

  • Meets IECC 2009
  • Meets IECC 2012

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface0.15 - 0.440.3

Install Uninsulated Ducts:

Before-Component After-Component Cost

15% Leakage, R-6

Properties:

  • Insulation Nominal R-Value: 6.0 h-ft^2-R/Btu
  • Total Leakage: 0.15

Performance Standards:

  • Meets IECC 2009
  • Meets IECC 2012

Lifetime:

  • 999 Years
 

None

Properties:

  • Insulation Nominal R-Value: h-ft^2-R/Btu
  • Total Leakage:

Lifetime:

  • Years
 

Measure Cost

UnitsRangeAverage
N/A0 - 00

Seal Ducts (Total Leakage):

Before-Component After-Component Cost

15% Leakage, R-8

Properties:

  • Insulation Nominal R-Value: 8.0 h-ft^2-R/Btu
  • Total Leakage: 0.15

Performance Standards:

  • Exceeds IECC 2012
  • Exceeds IECC 2009

Lifetime:

  • 999 Years
 

10% Leakage, R-8

Properties:

  • Insulation Nominal R-Value: 8.0 h-ft^2-R/Btu
  • Total Leakage: 0.1

Performance Standards:

  • Exceeds IECC 2009
  • Exceeds IECC 2012

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface0.1 - 0.290.2

Seal Ducts (Total Leakage):

Before-Component After-Component Cost

15% Leakage, R-8

Properties:

  • Insulation Nominal R-Value: 8.0 h-ft^2-R/Btu
  • Total Leakage: 0.15

Performance Standards:

  • Exceeds IECC 2012
  • Exceeds IECC 2009

Lifetime:

  • 999 Years
 

7.5% Leakage, R-8

Properties:

  • Insulation Nominal R-Value: 8.0 h-ft^2-R/Btu
  • Total Leakage: 0.075

Performance Standards:

  • Exceeds IECC 2012
  • Exceeds IECC 2009

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface0.15 - 0.440.3

Install Uninsulated Ducts:

Before-Component After-Component Cost

15% Leakage, R-8

Properties:

  • Insulation Nominal R-Value: 8.0 h-ft^2-R/Btu
  • Total Leakage: 0.15

Performance Standards:

  • Exceeds IECC 2012
  • Exceeds IECC 2009

Lifetime:

  • 999 Years
 

None

Properties:

  • Insulation Nominal R-Value: h-ft^2-R/Btu
  • Total Leakage:

Lifetime:

  • Years
 

Measure Cost

UnitsRangeAverage
N/A0 - 00

Seal and Insulate Ducts (Total Leakage):

Before-Component After-Component Cost

15% Leakage, Uninsulated

Properties:

  • Insulation Nominal R-Value: 0.0 h-ft^2-R/Btu
  • Total Leakage: 0.15

Lifetime:

  • 999 Years
 

10% Leakage, R-4

Properties:

  • Insulation Nominal R-Value: 4.0 h-ft^2-R/Btu
  • Total Leakage: 0.1

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface0.86 - 21.4

Seal and Insulate Ducts (Total Leakage):

Before-Component After-Component Cost

15% Leakage, Uninsulated

Properties:

  • Insulation Nominal R-Value: 0.0 h-ft^2-R/Btu
  • Total Leakage: 0.15

Lifetime:

  • 999 Years
 

10% Leakage, R-6

Properties:

  • Insulation Nominal R-Value: 6.0 h-ft^2-R/Btu
  • Total Leakage: 0.1

Performance Standards:

  • Meets IECC 2012
  • Meets IECC 2009

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface0.92 - 2.11.5

Seal and Insulate Ducts (Total Leakage):

Before-Component After-Component Cost

15% Leakage, Uninsulated

Properties:

  • Insulation Nominal R-Value: 0.0 h-ft^2-R/Btu
  • Total Leakage: 0.15

Lifetime:

  • 999 Years
 

10% Leakage, R-8

Properties:

  • Insulation Nominal R-Value: 8.0 h-ft^2-R/Btu
  • Total Leakage: 0.1

Performance Standards:

  • Exceeds IECC 2009
  • Exceeds IECC 2012

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface0.97 - 2.21.6

Seal Ducts (Total Leakage):

Before-Component After-Component Cost

15% Leakage, Uninsulated

Properties:

  • Insulation Nominal R-Value: 0.0 h-ft^2-R/Btu
  • Total Leakage: 0.15

Lifetime:

  • 999 Years
 

10% Leakage, Uninsulated

Properties:

  • Insulation Nominal R-Value: 0.0 h-ft^2-R/Btu
  • Total Leakage: 0.1

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface0.1 - 0.290.2

Seal Ducts:

Before-Component After-Component Cost

15% Leakage, Uninsulated

Properties:

  • Insulation Nominal R-Value: 0.0 h-ft^2-R/Btu
  • Total Leakage: 0.15

Lifetime:

  • 999 Years
 

15% Leakage, R-4

Properties:

  • Insulation Nominal R-Value: 4.0 h-ft^2-R/Btu
  • Total Leakage: 0.15

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface0.83 - 1.61.2

Seal Ducts:

Before-Component After-Component Cost

15% Leakage, Uninsulated

Properties:

  • Insulation Nominal R-Value: 0.0 h-ft^2-R/Btu
  • Total Leakage: 0.15

Lifetime:

  • 999 Years
 

15% Leakage, R-6

Properties:

  • Insulation Nominal R-Value: 6.0 h-ft^2-R/Btu
  • Total Leakage: 0.15

Performance Standards:

  • Meets IECC 2009
  • Meets IECC 2012

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface0.89 - 1.81.3

Seal Ducts:

Before-Component After-Component Cost

15% Leakage, Uninsulated

Properties:

  • Insulation Nominal R-Value: 0.0 h-ft^2-R/Btu
  • Total Leakage: 0.15

Lifetime:

  • 999 Years
 

15% Leakage, R-8

Properties:

  • Insulation Nominal R-Value: 8.0 h-ft^2-R/Btu
  • Total Leakage: 0.15

Performance Standards:

  • Exceeds IECC 2012
  • Exceeds IECC 2009

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface0.95 - 1.91.4

Seal and Insulate Ducts (Total Leakage):

Before-Component After-Component Cost

15% Leakage, Uninsulated

Properties:

  • Insulation Nominal R-Value: 0.0 h-ft^2-R/Btu
  • Total Leakage: 0.15

Lifetime:

  • 999 Years
 

7.5% Leakage, R-4

Properties:

  • Insulation Nominal R-Value: 4.0 h-ft^2-R/Btu
  • Total Leakage: 0.075

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface0.92 - 2.11.5

Seal and Insulate Ducts (Total Leakage):

Before-Component After-Component Cost

15% Leakage, Uninsulated

Properties:

  • Insulation Nominal R-Value: 0.0 h-ft^2-R/Btu
  • Total Leakage: 0.15

Lifetime:

  • 999 Years
 

7.5% Leakage, R-6

Properties:

  • Insulation Nominal R-Value: 6.0 h-ft^2-R/Btu
  • Total Leakage: 0.075

Performance Standards:

  • Meets IECC 2009
  • Meets IECC 2012

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface0.98 - 2.21.6

Seal and Insulate Ducts (Total Leakage):

Before-Component After-Component Cost

15% Leakage, Uninsulated

Properties:

  • Insulation Nominal R-Value: 0.0 h-ft^2-R/Btu
  • Total Leakage: 0.15

Lifetime:

  • 999 Years
 

7.5% Leakage, R-8

Properties:

  • Insulation Nominal R-Value: 8.0 h-ft^2-R/Btu
  • Total Leakage: 0.075

Performance Standards:

  • Exceeds IECC 2012
  • Exceeds IECC 2009

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface1 - 2.31.7

Seal Ducts (Total Leakage):

Before-Component After-Component Cost

15% Leakage, Uninsulated

Properties:

  • Insulation Nominal R-Value: 0.0 h-ft^2-R/Btu
  • Total Leakage: 0.15

Lifetime:

  • 999 Years
 

7.5% Leakage, Uninsulated

Properties:

  • Insulation Nominal R-Value: 0.0 h-ft^2-R/Btu
  • Total Leakage: 0.075

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface0.15 - 0.440.3

Install Uninsulated Ducts:

Before-Component After-Component Cost

15% Leakage, Uninsulated

Properties:

  • Insulation Nominal R-Value: 0.0 h-ft^2-R/Btu
  • Total Leakage: 0.15

Lifetime:

  • 999 Years
 

None

Properties:

  • Insulation Nominal R-Value: h-ft^2-R/Btu
  • Total Leakage:

Lifetime:

  • Years
 

Measure Cost

UnitsRangeAverage
N/A0 - 00

Seal Ducts (Total Leakage):

Before-Component After-Component Cost

20% Leakage, R-4

Properties:

  • Insulation Nominal R-Value: 4.0 h-ft^2-R/Btu
  • Total Leakage: 0.2

Lifetime:

  • 999 Years
 

10% Leakage, R-4

Properties:

  • Insulation Nominal R-Value: 4.0 h-ft^2-R/Btu
  • Total Leakage: 0.1

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface0.2 - 0.590.4

Seal Ducts (Total Leakage):

Before-Component After-Component Cost

20% Leakage, R-4

Properties:

  • Insulation Nominal R-Value: 4.0 h-ft^2-R/Btu
  • Total Leakage: 0.2

Lifetime:

  • 999 Years
 

15% Leakage, R-4

Properties:

  • Insulation Nominal R-Value: 4.0 h-ft^2-R/Btu
  • Total Leakage: 0.15

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface0.1 - 0.290.2

Seal Ducts (Total Leakage):

Before-Component After-Component Cost

20% Leakage, R-4

Properties:

  • Insulation Nominal R-Value: 4.0 h-ft^2-R/Btu
  • Total Leakage: 0.2

Lifetime:

  • 999 Years
 

7.5% Leakage, R-4

Properties:

  • Insulation Nominal R-Value: 4.0 h-ft^2-R/Btu
  • Total Leakage: 0.075

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface0.25 - 0.740.5

Install Uninsulated Ducts:

Before-Component After-Component Cost

20% Leakage, R-4

Properties:

  • Insulation Nominal R-Value: 4.0 h-ft^2-R/Btu
  • Total Leakage: 0.2

Lifetime:

  • 999 Years
 

None

Properties:

  • Insulation Nominal R-Value: h-ft^2-R/Btu
  • Total Leakage:

Lifetime:

  • Years
 

Measure Cost

UnitsRangeAverage
N/A0 - 00

Seal Ducts (Total Leakage):

Before-Component After-Component Cost

20% Leakage, R-6

Properties:

  • Insulation Nominal R-Value: 6.0 h-ft^2-R/Btu
  • Total Leakage: 0.2

Performance Standards:

  • Meets IECC 2012
  • Meets IECC 2009

Lifetime:

  • 999 Years
 

10% Leakage, R-6

Properties:

  • Insulation Nominal R-Value: 6.0 h-ft^2-R/Btu
  • Total Leakage: 0.1

Performance Standards:

  • Meets IECC 2012
  • Meets IECC 2009

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface0.2 - 0.590.4

Seal Ducts (Total Leakage):

Before-Component After-Component Cost

20% Leakage, R-6

Properties:

  • Insulation Nominal R-Value: 6.0 h-ft^2-R/Btu
  • Total Leakage: 0.2

Performance Standards:

  • Meets IECC 2012
  • Meets IECC 2009

Lifetime:

  • 999 Years
 

15% Leakage, R-6

Properties:

  • Insulation Nominal R-Value: 6.0 h-ft^2-R/Btu
  • Total Leakage: 0.15

Performance Standards:

  • Meets IECC 2009
  • Meets IECC 2012

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface0.1 - 0.290.2

Seal Ducts (Total Leakage):

Before-Component After-Component Cost

20% Leakage, R-6

Properties:

  • Insulation Nominal R-Value: 6.0 h-ft^2-R/Btu
  • Total Leakage: 0.2

Performance Standards:

  • Meets IECC 2012
  • Meets IECC 2009

Lifetime:

  • 999 Years
 

7.5% Leakage, R-6

Properties:

  • Insulation Nominal R-Value: 6.0 h-ft^2-R/Btu
  • Total Leakage: 0.075

Performance Standards:

  • Meets IECC 2009
  • Meets IECC 2012

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface0.25 - 0.740.5

Install Uninsulated Ducts:

Before-Component After-Component Cost

20% Leakage, R-6

Properties:

  • Insulation Nominal R-Value: 6.0 h-ft^2-R/Btu
  • Total Leakage: 0.2

Performance Standards:

  • Meets IECC 2012
  • Meets IECC 2009

Lifetime:

  • 999 Years
 

None

Properties:

  • Insulation Nominal R-Value: h-ft^2-R/Btu
  • Total Leakage:

Lifetime:

  • Years
 

Measure Cost

UnitsRangeAverage
N/A0 - 00

Seal Ducts (Total Leakage):

Before-Component After-Component Cost

20% Leakage, R-8

Properties:

  • Insulation Nominal R-Value: 8.0 h-ft^2-R/Btu
  • Total Leakage: 0.2

Performance Standards:

  • Exceeds IECC 2009
  • Exceeds IECC 2012

Lifetime:

  • 999 Years
 

10% Leakage, R-8

Properties:

  • Insulation Nominal R-Value: 8.0 h-ft^2-R/Btu
  • Total Leakage: 0.1

Performance Standards:

  • Exceeds IECC 2009
  • Exceeds IECC 2012

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface0.2 - 0.590.4

Seal Ducts (Total Leakage):

Before-Component After-Component Cost

20% Leakage, R-8

Properties:

  • Insulation Nominal R-Value: 8.0 h-ft^2-R/Btu
  • Total Leakage: 0.2

Performance Standards:

  • Exceeds IECC 2009
  • Exceeds IECC 2012

Lifetime:

  • 999 Years
 

15% Leakage, R-8

Properties:

  • Insulation Nominal R-Value: 8.0 h-ft^2-R/Btu
  • Total Leakage: 0.15

Performance Standards:

  • Exceeds IECC 2012
  • Exceeds IECC 2009

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface0.1 - 0.290.2

Seal Ducts (Total Leakage):

Before-Component After-Component Cost

20% Leakage, R-8

Properties:

  • Insulation Nominal R-Value: 8.0 h-ft^2-R/Btu
  • Total Leakage: 0.2

Performance Standards:

  • Exceeds IECC 2009
  • Exceeds IECC 2012

Lifetime:

  • 999 Years
 

7.5% Leakage, R-8

Properties:

  • Insulation Nominal R-Value: 8.0 h-ft^2-R/Btu
  • Total Leakage: 0.075

Performance Standards:

  • Exceeds IECC 2012
  • Exceeds IECC 2009

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface0.25 - 0.740.5

Install Uninsulated Ducts:

Before-Component After-Component Cost

20% Leakage, R-8

Properties:

  • Insulation Nominal R-Value: 8.0 h-ft^2-R/Btu
  • Total Leakage: 0.2

Performance Standards:

  • Exceeds IECC 2009
  • Exceeds IECC 2012

Lifetime:

  • 999 Years
 

None

Properties:

  • Insulation Nominal R-Value: h-ft^2-R/Btu
  • Total Leakage:

Lifetime:

  • Years
 

Measure Cost

UnitsRangeAverage
N/A0 - 00

Seal and Insulate Ducts (Total Leakage):

Before-Component After-Component Cost

20% Leakage, Uninsulated

Properties:

  • Insulation Nominal R-Value: 0.0 h-ft^2-R/Btu
  • Total Leakage: 0.2

Lifetime:

  • 999 Years
 

10% Leakage, R-4

Properties:

  • Insulation Nominal R-Value: 4.0 h-ft^2-R/Btu
  • Total Leakage: 0.1

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface0.98 - 2.31.6

Seal and Insulate Ducts (Total Leakage):

Before-Component After-Component Cost

20% Leakage, Uninsulated

Properties:

  • Insulation Nominal R-Value: 0.0 h-ft^2-R/Btu
  • Total Leakage: 0.2

Lifetime:

  • 999 Years
 

10% Leakage, R-6

Properties:

  • Insulation Nominal R-Value: 6.0 h-ft^2-R/Btu
  • Total Leakage: 0.1

Performance Standards:

  • Meets IECC 2012
  • Meets IECC 2009

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface1 - 2.41.7

Seal and Insulate Ducts (Total Leakage):

Before-Component After-Component Cost

20% Leakage, Uninsulated

Properties:

  • Insulation Nominal R-Value: 0.0 h-ft^2-R/Btu
  • Total Leakage: 0.2

Lifetime:

  • 999 Years
 

10% Leakage, R-8

Properties:

  • Insulation Nominal R-Value: 8.0 h-ft^2-R/Btu
  • Total Leakage: 0.1

Performance Standards:

  • Exceeds IECC 2009
  • Exceeds IECC 2012

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface1.1 - 2.51.8

Seal Ducts (Total Leakage):

Before-Component After-Component Cost

20% Leakage, Uninsulated

Properties:

  • Insulation Nominal R-Value: 0.0 h-ft^2-R/Btu
  • Total Leakage: 0.2

Lifetime:

  • 999 Years
 

10% Leakage, Uninsulated

Properties:

  • Insulation Nominal R-Value: 0.0 h-ft^2-R/Btu
  • Total Leakage: 0.1

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface0.2 - 0.590.4

Seal and Insulate Ducts (Total Leakage):

Before-Component After-Component Cost

20% Leakage, Uninsulated

Properties:

  • Insulation Nominal R-Value: 0.0 h-ft^2-R/Btu
  • Total Leakage: 0.2

Lifetime:

  • 999 Years
 

15% Leakage, R-4

Properties:

  • Insulation Nominal R-Value: 4.0 h-ft^2-R/Btu
  • Total Leakage: 0.15

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface0.86 - 21.4

Seal and Insulate Ducts (Total Leakage):

Before-Component After-Component Cost

20% Leakage, Uninsulated

Properties:

  • Insulation Nominal R-Value: 0.0 h-ft^2-R/Btu
  • Total Leakage: 0.2

Lifetime:

  • 999 Years
 

15% Leakage, R-6

Properties:

  • Insulation Nominal R-Value: 6.0 h-ft^2-R/Btu
  • Total Leakage: 0.15

Performance Standards:

  • Meets IECC 2009
  • Meets IECC 2012

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface0.92 - 2.11.5

Seal and Insulate Ducts (Total Leakage):

Before-Component After-Component Cost

20% Leakage, Uninsulated

Properties:

  • Insulation Nominal R-Value: 0.0 h-ft^2-R/Btu
  • Total Leakage: 0.2

Lifetime:

  • 999 Years
 

15% Leakage, R-8

Properties:

  • Insulation Nominal R-Value: 8.0 h-ft^2-R/Btu
  • Total Leakage: 0.15

Performance Standards:

  • Exceeds IECC 2012
  • Exceeds IECC 2009

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface0.97 - 2.21.6

Seal Ducts (Total Leakage):

Before-Component After-Component Cost

20% Leakage, Uninsulated

Properties:

  • Insulation Nominal R-Value: 0.0 h-ft^2-R/Btu
  • Total Leakage: 0.2

Lifetime:

  • 999 Years
 

15% Leakage, Uninsulated

Properties:

  • Insulation Nominal R-Value: 0.0 h-ft^2-R/Btu
  • Total Leakage: 0.15

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface0.1 - 0.290.2

Seal Ducts:

Before-Component After-Component Cost

20% Leakage, Uninsulated

Properties:

  • Insulation Nominal R-Value: 0.0 h-ft^2-R/Btu
  • Total Leakage: 0.2

Lifetime:

  • 999 Years
 

20% Leakage, R-4

Properties:

  • Insulation Nominal R-Value: 4.0 h-ft^2-R/Btu
  • Total Leakage: 0.2

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface0.83 - 1.61.2

Seal Ducts:

Before-Component After-Component Cost

20% Leakage, Uninsulated

Properties:

  • Insulation Nominal R-Value: 0.0 h-ft^2-R/Btu
  • Total Leakage: 0.2

Lifetime:

  • 999 Years
 

20% Leakage, R-6

Properties:

  • Insulation Nominal R-Value: 6.0 h-ft^2-R/Btu
  • Total Leakage: 0.2

Performance Standards:

  • Meets IECC 2012
  • Meets IECC 2009

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface0.89 - 1.81.3

Seal Ducts:

Before-Component After-Component Cost

20% Leakage, Uninsulated

Properties:

  • Insulation Nominal R-Value: 0.0 h-ft^2-R/Btu
  • Total Leakage: 0.2

Lifetime:

  • 999 Years
 

20% Leakage, R-8

Properties:

  • Insulation Nominal R-Value: 8.0 h-ft^2-R/Btu
  • Total Leakage: 0.2

Performance Standards:

  • Exceeds IECC 2009
  • Exceeds IECC 2012

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface0.95 - 1.91.4

Seal and Insulate Ducts (Total Leakage):

Before-Component After-Component Cost

20% Leakage, Uninsulated

Properties:

  • Insulation Nominal R-Value: 0.0 h-ft^2-R/Btu
  • Total Leakage: 0.2

Lifetime:

  • 999 Years
 

7.5% Leakage, R-4

Properties:

  • Insulation Nominal R-Value: 4.0 h-ft^2-R/Btu
  • Total Leakage: 0.075

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface1 - 2.41.7

Seal and Insulate Ducts (Total Leakage):

Before-Component After-Component Cost

20% Leakage, Uninsulated

Properties:

  • Insulation Nominal R-Value: 0.0 h-ft^2-R/Btu
  • Total Leakage: 0.2

Lifetime:

  • 999 Years
 

7.5% Leakage, R-6

Properties:

  • Insulation Nominal R-Value: 6.0 h-ft^2-R/Btu
  • Total Leakage: 0.075

Performance Standards:

  • Meets IECC 2009
  • Meets IECC 2012

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface1.1 - 2.51.8

Seal and Insulate Ducts (Total Leakage):

Before-Component After-Component Cost

20% Leakage, Uninsulated

Properties:

  • Insulation Nominal R-Value: 0.0 h-ft^2-R/Btu
  • Total Leakage: 0.2

Lifetime:

  • 999 Years
 

7.5% Leakage, R-8

Properties:

  • Insulation Nominal R-Value: 8.0 h-ft^2-R/Btu
  • Total Leakage: 0.075

Performance Standards:

  • Exceeds IECC 2012
  • Exceeds IECC 2009

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface1.2 - 2.61.9

Seal Ducts (Total Leakage):

Before-Component After-Component Cost

20% Leakage, Uninsulated

Properties:

  • Insulation Nominal R-Value: 0.0 h-ft^2-R/Btu
  • Total Leakage: 0.2

Lifetime:

  • 999 Years
 

7.5% Leakage, Uninsulated

Properties:

  • Insulation Nominal R-Value: 0.0 h-ft^2-R/Btu
  • Total Leakage: 0.075

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface0.25 - 0.740.5

Install Uninsulated Ducts:

Before-Component After-Component Cost

20% Leakage, Uninsulated

Properties:

  • Insulation Nominal R-Value: 0.0 h-ft^2-R/Btu
  • Total Leakage: 0.2

Lifetime:

  • 999 Years
 

None

Properties:

  • Insulation Nominal R-Value: h-ft^2-R/Btu
  • Total Leakage:

Lifetime:

  • Years
 

Measure Cost

UnitsRangeAverage
N/A0 - 00

Seal Ducts (Total Leakage):

Before-Component After-Component Cost

30% Leakage, R-4

Properties:

  • Insulation Nominal R-Value: 4.0 h-ft^2-R/Btu
  • Total Leakage: 0.3

Lifetime:

  • 999 Years
 

10% Leakage, R-4

Properties:

  • Insulation Nominal R-Value: 4.0 h-ft^2-R/Btu
  • Total Leakage: 0.1

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface0.4 - 1.20.81

Seal Ducts (Total Leakage):

Before-Component After-Component Cost

30% Leakage, R-4

Properties:

  • Insulation Nominal R-Value: 4.0 h-ft^2-R/Btu
  • Total Leakage: 0.3

Lifetime:

  • 999 Years
 

15% Leakage, R-4

Properties:

  • Insulation Nominal R-Value: 4.0 h-ft^2-R/Btu
  • Total Leakage: 0.15

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface0.3 - 0.880.61

Seal Ducts (Total Leakage):

Before-Component After-Component Cost

30% Leakage, R-4

Properties:

  • Insulation Nominal R-Value: 4.0 h-ft^2-R/Btu
  • Total Leakage: 0.3

Lifetime:

  • 999 Years
 

20% Leakage, R-4

Properties:

  • Insulation Nominal R-Value: 4.0 h-ft^2-R/Btu
  • Total Leakage: 0.2

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface0.2 - 0.590.4

Seal Ducts (Total Leakage):

Before-Component After-Component Cost

30% Leakage, R-4

Properties:

  • Insulation Nominal R-Value: 4.0 h-ft^2-R/Btu
  • Total Leakage: 0.3

Lifetime:

  • 999 Years
 

7.5% Leakage, R-4

Properties:

  • Insulation Nominal R-Value: 4.0 h-ft^2-R/Btu
  • Total Leakage: 0.075

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface0.45 - 1.30.91

Install Uninsulated Ducts:

Before-Component After-Component Cost

30% Leakage, R-4

Properties:

  • Insulation Nominal R-Value: 4.0 h-ft^2-R/Btu
  • Total Leakage: 0.3

Lifetime:

  • 999 Years
 

None

Properties:

  • Insulation Nominal R-Value: h-ft^2-R/Btu
  • Total Leakage:

Lifetime:

  • Years
 

Measure Cost

UnitsRangeAverage
N/A0 - 00

Seal Ducts (Total Leakage):

Before-Component After-Component Cost

30% Leakage, R-6

Properties:

  • Insulation Nominal R-Value: 6.0 h-ft^2-R/Btu
  • Total Leakage: 0.3

Performance Standards:

  • Meets IECC 2012
  • Meets IECC 2009

Lifetime:

  • 999 Years
 

10% Leakage, R-6

Properties:

  • Insulation Nominal R-Value: 6.0 h-ft^2-R/Btu
  • Total Leakage: 0.1

Performance Standards:

  • Meets IECC 2012
  • Meets IECC 2009

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface0.4 - 1.20.81

Seal Ducts (Total Leakage):

Before-Component After-Component Cost

30% Leakage, R-6

Properties:

  • Insulation Nominal R-Value: 6.0 h-ft^2-R/Btu
  • Total Leakage: 0.3

Performance Standards:

  • Meets IECC 2012
  • Meets IECC 2009

Lifetime:

  • 999 Years
 

15% Leakage, R-6

Properties:

  • Insulation Nominal R-Value: 6.0 h-ft^2-R/Btu
  • Total Leakage: 0.15

Performance Standards:

  • Meets IECC 2009
  • Meets IECC 2012

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface0.3 - 0.880.61

Seal Ducts (Total Leakage):

Before-Component After-Component Cost

30% Leakage, R-6

Properties:

  • Insulation Nominal R-Value: 6.0 h-ft^2-R/Btu
  • Total Leakage: 0.3

Performance Standards:

  • Meets IECC 2012
  • Meets IECC 2009

Lifetime:

  • 999 Years
 

20% Leakage, R-6

Properties:

  • Insulation Nominal R-Value: 6.0 h-ft^2-R/Btu
  • Total Leakage: 0.2

Performance Standards:

  • Meets IECC 2012
  • Meets IECC 2009

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface0.2 - 0.590.4

Seal Ducts (Total Leakage):

Before-Component After-Component Cost

30% Leakage, R-6

Properties:

  • Insulation Nominal R-Value: 6.0 h-ft^2-R/Btu
  • Total Leakage: 0.3

Performance Standards:

  • Meets IECC 2012
  • Meets IECC 2009

Lifetime:

  • 999 Years
 

7.5% Leakage, R-6

Properties:

  • Insulation Nominal R-Value: 6.0 h-ft^2-R/Btu
  • Total Leakage: 0.075

Performance Standards:

  • Meets IECC 2009
  • Meets IECC 2012

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface0.45 - 1.30.91

Install Uninsulated Ducts:

Before-Component After-Component Cost

30% Leakage, R-6

Properties:

  • Insulation Nominal R-Value: 6.0 h-ft^2-R/Btu
  • Total Leakage: 0.3

Performance Standards:

  • Meets IECC 2012
  • Meets IECC 2009

Lifetime:

  • 999 Years
 

None

Properties:

  • Insulation Nominal R-Value: h-ft^2-R/Btu
  • Total Leakage:

Lifetime:

  • Years
 

Measure Cost

UnitsRangeAverage
N/A0 - 00

Seal Ducts (Total Leakage):

Before-Component After-Component Cost

30% Leakage, R-8

Properties:

  • Insulation Nominal R-Value: 8.0 h-ft^2-R/Btu
  • Total Leakage: 0.3

Performance Standards:

  • Exceeds IECC 2009
  • Exceeds IECC 2012

Lifetime:

  • 999 Years
 

10% Leakage, R-8

Properties:

  • Insulation Nominal R-Value: 8.0 h-ft^2-R/Btu
  • Total Leakage: 0.1

Performance Standards:

  • Exceeds IECC 2009
  • Exceeds IECC 2012

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface0.4 - 1.20.81

Seal Ducts (Total Leakage):

Before-Component After-Component Cost

30% Leakage, R-8

Properties:

  • Insulation Nominal R-Value: 8.0 h-ft^2-R/Btu
  • Total Leakage: 0.3

Performance Standards:

  • Exceeds IECC 2009
  • Exceeds IECC 2012

Lifetime:

  • 999 Years
 

15% Leakage, R-8

Properties:

  • Insulation Nominal R-Value: 8.0 h-ft^2-R/Btu
  • Total Leakage: 0.15

Performance Standards:

  • Exceeds IECC 2012
  • Exceeds IECC 2009

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface0.3 - 0.880.61

Seal Ducts (Total Leakage):

Before-Component After-Component Cost

30% Leakage, R-8

Properties:

  • Insulation Nominal R-Value: 8.0 h-ft^2-R/Btu
  • Total Leakage: 0.3

Performance Standards:

  • Exceeds IECC 2009
  • Exceeds IECC 2012

Lifetime:

  • 999 Years
 

20% Leakage, R-8

Properties:

  • Insulation Nominal R-Value: 8.0 h-ft^2-R/Btu
  • Total Leakage: 0.2

Performance Standards:

  • Exceeds IECC 2009
  • Exceeds IECC 2012

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface0.2 - 0.590.4

Seal Ducts (Total Leakage):

Before-Component After-Component Cost

30% Leakage, R-8

Properties:

  • Insulation Nominal R-Value: 8.0 h-ft^2-R/Btu
  • Total Leakage: 0.3

Performance Standards:

  • Exceeds IECC 2009
  • Exceeds IECC 2012

Lifetime:

  • 999 Years
 

7.5% Leakage, R-8

Properties:

  • Insulation Nominal R-Value: 8.0 h-ft^2-R/Btu
  • Total Leakage: 0.075

Performance Standards:

  • Exceeds IECC 2012
  • Exceeds IECC 2009

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface0.45 - 1.30.91

Install Uninsulated Ducts:

Before-Component After-Component Cost

30% Leakage, R-8

Properties:

  • Insulation Nominal R-Value: 8.0 h-ft^2-R/Btu
  • Total Leakage: 0.3

Performance Standards:

  • Exceeds IECC 2009
  • Exceeds IECC 2012

Lifetime:

  • 999 Years
 

None

Properties:

  • Insulation Nominal R-Value: h-ft^2-R/Btu
  • Total Leakage:

Lifetime:

  • Years
 

Measure Cost

UnitsRangeAverage
N/A0 - 00

Seal and Insulate Ducts (Total Leakage):

Before-Component After-Component Cost

30% Leakage, Uninsulated

Properties:

  • Insulation Nominal R-Value: 0.0 h-ft^2-R/Btu
  • Total Leakage: 0.3

Lifetime:

  • 999 Years
 

10% Leakage, R-4

Properties:

  • Insulation Nominal R-Value: 4.0 h-ft^2-R/Btu
  • Total Leakage: 0.1

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface1.2 - 2.82

Seal and Insulate Ducts (Total Leakage):

Before-Component After-Component Cost

30% Leakage, Uninsulated

Properties:

  • Insulation Nominal R-Value: 0.0 h-ft^2-R/Btu
  • Total Leakage: 0.3

Lifetime:

  • 999 Years
 

10% Leakage, R-6

Properties:

  • Insulation Nominal R-Value: 6.0 h-ft^2-R/Btu
  • Total Leakage: 0.1

Performance Standards:

  • Meets IECC 2012
  • Meets IECC 2009

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface1.3 - 2.92.1

Seal and Insulate Ducts (Total Leakage):

Before-Component After-Component Cost

30% Leakage, Uninsulated

Properties:

  • Insulation Nominal R-Value: 0.0 h-ft^2-R/Btu
  • Total Leakage: 0.3

Lifetime:

  • 999 Years
 

10% Leakage, R-8

Properties:

  • Insulation Nominal R-Value: 8.0 h-ft^2-R/Btu
  • Total Leakage: 0.1

Performance Standards:

  • Exceeds IECC 2009
  • Exceeds IECC 2012

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface1.3 - 32.2

Seal Ducts (Total Leakage):

Before-Component After-Component Cost

30% Leakage, Uninsulated

Properties:

  • Insulation Nominal R-Value: 0.0 h-ft^2-R/Btu
  • Total Leakage: 0.3

Lifetime:

  • 999 Years
 

10% Leakage, Uninsulated

Properties:

  • Insulation Nominal R-Value: 0.0 h-ft^2-R/Btu
  • Total Leakage: 0.1

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface0.4 - 1.20.81

Seal and Insulate Ducts (Total Leakage):

Before-Component After-Component Cost

30% Leakage, Uninsulated

Properties:

  • Insulation Nominal R-Value: 0.0 h-ft^2-R/Btu
  • Total Leakage: 0.3

Lifetime:

  • 999 Years
 

15% Leakage, R-4

Properties:

  • Insulation Nominal R-Value: 4.0 h-ft^2-R/Btu
  • Total Leakage: 0.15

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface1.1 - 2.51.8

Seal and Insulate Ducts (Total Leakage):

Before-Component After-Component Cost

30% Leakage, Uninsulated

Properties:

  • Insulation Nominal R-Value: 0.0 h-ft^2-R/Btu
  • Total Leakage: 0.3

Lifetime:

  • 999 Years
 

15% Leakage, R-6

Properties:

  • Insulation Nominal R-Value: 6.0 h-ft^2-R/Btu
  • Total Leakage: 0.15

Performance Standards:

  • Meets IECC 2009
  • Meets IECC 2012

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface1.2 - 2.71.9

Seal and Insulate Ducts (Total Leakage):

Before-Component After-Component Cost

30% Leakage, Uninsulated

Properties:

  • Insulation Nominal R-Value: 0.0 h-ft^2-R/Btu
  • Total Leakage: 0.3

Lifetime:

  • 999 Years
 

15% Leakage, R-8

Properties:

  • Insulation Nominal R-Value: 8.0 h-ft^2-R/Btu
  • Total Leakage: 0.15

Performance Standards:

  • Exceeds IECC 2012
  • Exceeds IECC 2009

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface1.2 - 2.82

Seal Ducts (Total Leakage):

Before-Component After-Component Cost

30% Leakage, Uninsulated

Properties:

  • Insulation Nominal R-Value: 0.0 h-ft^2-R/Btu
  • Total Leakage: 0.3

Lifetime:

  • 999 Years
 

15% Leakage, Uninsulated

Properties:

  • Insulation Nominal R-Value: 0.0 h-ft^2-R/Btu
  • Total Leakage: 0.15

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface0.3 - 0.880.61

Seal and Insulate Ducts (Total Leakage):

Before-Component After-Component Cost

30% Leakage, Uninsulated

Properties:

  • Insulation Nominal R-Value: 0.0 h-ft^2-R/Btu
  • Total Leakage: 0.3

Lifetime:

  • 999 Years
 

20% Leakage, R-4

Properties:

  • Insulation Nominal R-Value: 4.0 h-ft^2-R/Btu
  • Total Leakage: 0.2

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface0.98 - 2.31.6

Seal and Insulate Ducts (Total Leakage):

Before-Component After-Component Cost

30% Leakage, Uninsulated

Properties:

  • Insulation Nominal R-Value: 0.0 h-ft^2-R/Btu
  • Total Leakage: 0.3

Lifetime:

  • 999 Years
 

20% Leakage, R-6

Properties:

  • Insulation Nominal R-Value: 6.0 h-ft^2-R/Btu
  • Total Leakage: 0.2

Performance Standards:

  • Meets IECC 2012
  • Meets IECC 2009

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface1 - 2.41.7

Seal and Insulate Ducts (Total Leakage):

Before-Component After-Component Cost

30% Leakage, Uninsulated

Properties:

  • Insulation Nominal R-Value: 0.0 h-ft^2-R/Btu
  • Total Leakage: 0.3

Lifetime:

  • 999 Years
 

20% Leakage, R-8

Properties:

  • Insulation Nominal R-Value: 8.0 h-ft^2-R/Btu
  • Total Leakage: 0.2

Performance Standards:

  • Exceeds IECC 2009
  • Exceeds IECC 2012

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface1.1 - 2.51.8

Seal Ducts (Total Leakage):

Before-Component After-Component Cost

30% Leakage, Uninsulated

Properties:

  • Insulation Nominal R-Value: 0.0 h-ft^2-R/Btu
  • Total Leakage: 0.3

Lifetime:

  • 999 Years
 

20% Leakage, Uninsulated

Properties:

  • Insulation Nominal R-Value: 0.0 h-ft^2-R/Btu
  • Total Leakage: 0.2

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface0.2 - 0.590.4

Seal Ducts:

Before-Component After-Component Cost

30% Leakage, Uninsulated

Properties:

  • Insulation Nominal R-Value: 0.0 h-ft^2-R/Btu
  • Total Leakage: 0.3

Lifetime:

  • 999 Years
 

30% Leakage, R-4

Properties:

  • Insulation Nominal R-Value: 4.0 h-ft^2-R/Btu
  • Total Leakage: 0.3

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface0.83 - 1.61.2

Seal Ducts:

Before-Component After-Component Cost

30% Leakage, Uninsulated

Properties:

  • Insulation Nominal R-Value: 0.0 h-ft^2-R/Btu
  • Total Leakage: 0.3

Lifetime:

  • 999 Years
 

30% Leakage, R-6

Properties:

  • Insulation Nominal R-Value: 6.0 h-ft^2-R/Btu
  • Total Leakage: 0.3

Performance Standards:

  • Meets IECC 2012
  • Meets IECC 2009

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface0.89 - 1.81.3

Seal Ducts:

Before-Component After-Component Cost

30% Leakage, Uninsulated

Properties:

  • Insulation Nominal R-Value: 0.0 h-ft^2-R/Btu
  • Total Leakage: 0.3

Lifetime:

  • 999 Years
 

30% Leakage, R-8

Properties:

  • Insulation Nominal R-Value: 8.0 h-ft^2-R/Btu
  • Total Leakage: 0.3

Performance Standards:

  • Exceeds IECC 2009
  • Exceeds IECC 2012

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface0.95 - 1.91.4

Seal and Insulate Ducts (Total Leakage):

Before-Component After-Component Cost

30% Leakage, Uninsulated

Properties:

  • Insulation Nominal R-Value: 0.0 h-ft^2-R/Btu
  • Total Leakage: 0.3

Lifetime:

  • 999 Years
 

7.5% Leakage, R-4

Properties:

  • Insulation Nominal R-Value: 4.0 h-ft^2-R/Btu
  • Total Leakage: 0.075

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface1.3 - 32.1

Seal and Insulate Ducts (Total Leakage):

Before-Component After-Component Cost

30% Leakage, Uninsulated

Properties:

  • Insulation Nominal R-Value: 0.0 h-ft^2-R/Btu
  • Total Leakage: 0.3

Lifetime:

  • 999 Years
 

7.5% Leakage, R-6

Properties:

  • Insulation Nominal R-Value: 6.0 h-ft^2-R/Btu
  • Total Leakage: 0.075

Performance Standards:

  • Meets IECC 2009
  • Meets IECC 2012

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface1.3 - 3.12.2

Seal and Insulate Ducts (Total Leakage):

Before-Component After-Component Cost

30% Leakage, Uninsulated

Properties:

  • Insulation Nominal R-Value: 0.0 h-ft^2-R/Btu
  • Total Leakage: 0.3

Lifetime:

  • 999 Years
 

7.5% Leakage, R-8

Properties:

  • Insulation Nominal R-Value: 8.0 h-ft^2-R/Btu
  • Total Leakage: 0.075

Performance Standards:

  • Exceeds IECC 2012
  • Exceeds IECC 2009

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface1.4 - 3.22.3

Seal Ducts (Total Leakage):

Before-Component After-Component Cost

30% Leakage, Uninsulated

Properties:

  • Insulation Nominal R-Value: 0.0 h-ft^2-R/Btu
  • Total Leakage: 0.3

Lifetime:

  • 999 Years
 

7.5% Leakage, Uninsulated

Properties:

  • Insulation Nominal R-Value: 0.0 h-ft^2-R/Btu
  • Total Leakage: 0.075

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface0.45 - 1.30.91

Install Uninsulated Ducts:

Before-Component After-Component Cost

30% Leakage, Uninsulated

Properties:

  • Insulation Nominal R-Value: 0.0 h-ft^2-R/Btu
  • Total Leakage: 0.3

Lifetime:

  • 999 Years
 

None

Properties:

  • Insulation Nominal R-Value: h-ft^2-R/Btu
  • Total Leakage:

Lifetime:

  • Years
 

Measure Cost

UnitsRangeAverage
N/A0 - 00

Install Uninsulated Ducts:

Before-Component After-Component Cost

7.5% Leakage, R-4

Properties:

  • Insulation Nominal R-Value: 4.0 h-ft^2-R/Btu
  • Total Leakage: 0.075

Lifetime:

  • 999 Years
 

None

Properties:

  • Insulation Nominal R-Value: h-ft^2-R/Btu
  • Total Leakage:

Lifetime:

  • Years
 

Measure Cost

UnitsRangeAverage
N/A0 - 00

Install Uninsulated Ducts:

Before-Component After-Component Cost

7.5% Leakage, R-6

Properties:

  • Insulation Nominal R-Value: 6.0 h-ft^2-R/Btu
  • Total Leakage: 0.075

Performance Standards:

  • Meets IECC 2009
  • Meets IECC 2012

Lifetime:

  • 999 Years
 

None

Properties:

  • Insulation Nominal R-Value: h-ft^2-R/Btu
  • Total Leakage:

Lifetime:

  • Years
 

Measure Cost

UnitsRangeAverage
N/A0 - 00

Install Uninsulated Ducts:

Before-Component After-Component Cost

7.5% Leakage, R-8

Properties:

  • Insulation Nominal R-Value: 8.0 h-ft^2-R/Btu
  • Total Leakage: 0.075

Performance Standards:

  • Exceeds IECC 2012
  • Exceeds IECC 2009

Lifetime:

  • 999 Years
 

None

Properties:

  • Insulation Nominal R-Value: h-ft^2-R/Btu
  • Total Leakage:

Lifetime:

  • Years
 

Measure Cost

UnitsRangeAverage
N/A0 - 00

Seal Ducts:

Before-Component After-Component Cost

7.5% Leakage, Uninsulated

Properties:

  • Insulation Nominal R-Value: 0.0 h-ft^2-R/Btu
  • Total Leakage: 0.075

Lifetime:

  • 999 Years
 

7.5% Leakage, R-4

Properties:

  • Insulation Nominal R-Value: 4.0 h-ft^2-R/Btu
  • Total Leakage: 0.075

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface0.83 - 1.61.2

Seal Ducts:

Before-Component After-Component Cost

7.5% Leakage, Uninsulated

Properties:

  • Insulation Nominal R-Value: 0.0 h-ft^2-R/Btu
  • Total Leakage: 0.075

Lifetime:

  • 999 Years
 

7.5% Leakage, R-6

Properties:

  • Insulation Nominal R-Value: 6.0 h-ft^2-R/Btu
  • Total Leakage: 0.075

Performance Standards:

  • Meets IECC 2009
  • Meets IECC 2012

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface0.89 - 1.81.3

Seal Ducts:

Before-Component After-Component Cost

7.5% Leakage, Uninsulated

Properties:

  • Insulation Nominal R-Value: 0.0 h-ft^2-R/Btu
  • Total Leakage: 0.075

Lifetime:

  • 999 Years
 

7.5% Leakage, R-8

Properties:

  • Insulation Nominal R-Value: 8.0 h-ft^2-R/Btu
  • Total Leakage: 0.075

Performance Standards:

  • Exceeds IECC 2012
  • Exceeds IECC 2009

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface0.95 - 1.91.4

Install Uninsulated Ducts:

Before-Component After-Component Cost

7.5% Leakage, Uninsulated

Properties:

  • Insulation Nominal R-Value: 0.0 h-ft^2-R/Btu
  • Total Leakage: 0.075

Lifetime:

  • 999 Years
 

None

Properties:

  • Insulation Nominal R-Value: h-ft^2-R/Btu
  • Total Leakage:

Lifetime:

  • Years
 

Measure Cost

UnitsRangeAverage
N/A0 - 00

Install Uninsulated Ducts:

Before-Component After-Component Cost

None

Properties:

  • Insulation Nominal R-Value: h-ft^2-R/Btu
  • Total Leakage:

Lifetime:

  • Years
 

10% Leakage, R-4

Properties:

  • Insulation Nominal R-Value: 4.0 h-ft^2-R/Btu
  • Total Leakage: 0.1

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface5.2 - 8.56.8

Install Uninsulated Ducts:

Before-Component After-Component Cost

None

Properties:

  • Insulation Nominal R-Value: h-ft^2-R/Btu
  • Total Leakage:

Lifetime:

  • Years
 

10% Leakage, R-6

Properties:

  • Insulation Nominal R-Value: 6.0 h-ft^2-R/Btu
  • Total Leakage: 0.1

Performance Standards:

  • Meets IECC 2012
  • Meets IECC 2009

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface5.2 - 8.66.9

Install Uninsulated Ducts:

Before-Component After-Component Cost

None

Properties:

  • Insulation Nominal R-Value: h-ft^2-R/Btu
  • Total Leakage:

Lifetime:

  • Years
 

10% Leakage, R-8

Properties:

  • Insulation Nominal R-Value: 8.0 h-ft^2-R/Btu
  • Total Leakage: 0.1

Performance Standards:

  • Exceeds IECC 2009
  • Exceeds IECC 2012

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface5.3 - 8.77

Install Uninsulated Ducts (Total Leakage):

Before-Component After-Component Cost

None

Properties:

  • Insulation Nominal R-Value: h-ft^2-R/Btu
  • Total Leakage:

Lifetime:

  • Years
 

10% Leakage, Uninsulated

Properties:

  • Insulation Nominal R-Value: 0.0 h-ft^2-R/Btu
  • Total Leakage: 0.1

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface4.3 - 6.45.3

Install Uninsulated Ducts:

Before-Component After-Component Cost

None

Properties:

  • Insulation Nominal R-Value: h-ft^2-R/Btu
  • Total Leakage:

Lifetime:

  • Years
 

15% Leakage, R-4

Properties:

  • Insulation Nominal R-Value: 4.0 h-ft^2-R/Btu
  • Total Leakage: 0.15

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface4.8 - 8.36.6

Install Uninsulated Ducts:

Before-Component After-Component Cost

None

Properties:

  • Insulation Nominal R-Value: h-ft^2-R/Btu
  • Total Leakage:

Lifetime:

  • Years
 

15% Leakage, R-6

Properties:

  • Insulation Nominal R-Value: 6.0 h-ft^2-R/Btu
  • Total Leakage: 0.15

Performance Standards:

  • Meets IECC 2009
  • Meets IECC 2012

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface4.9 - 8.56.7

Install Uninsulated Ducts:

Before-Component After-Component Cost

None

Properties:

  • Insulation Nominal R-Value: h-ft^2-R/Btu
  • Total Leakage:

Lifetime:

  • Years
 

15% Leakage, R-8

Properties:

  • Insulation Nominal R-Value: 8.0 h-ft^2-R/Btu
  • Total Leakage: 0.15

Performance Standards:

  • Exceeds IECC 2012
  • Exceeds IECC 2009

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface4.9 - 8.66.7

Install Uninsulated Ducts (Total Leakage):

Before-Component After-Component Cost

None

Properties:

  • Insulation Nominal R-Value: h-ft^2-R/Btu
  • Total Leakage:

Lifetime:

  • Years
 

15% Leakage, Uninsulated

Properties:

  • Insulation Nominal R-Value: 0.0 h-ft^2-R/Btu
  • Total Leakage: 0.15

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface3.9 - 6.35.1

Install Uninsulated Ducts:

Before-Component After-Component Cost

None

Properties:

  • Insulation Nominal R-Value: h-ft^2-R/Btu
  • Total Leakage:

Lifetime:

  • Years
 

20% Leakage, R-4

Properties:

  • Insulation Nominal R-Value: 4.0 h-ft^2-R/Btu
  • Total Leakage: 0.2

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface4.4 - 8.26.3

Install Uninsulated Ducts:

Before-Component After-Component Cost

None

Properties:

  • Insulation Nominal R-Value: h-ft^2-R/Btu
  • Total Leakage:

Lifetime:

  • Years
 

20% Leakage, R-6

Properties:

  • Insulation Nominal R-Value: 6.0 h-ft^2-R/Btu
  • Total Leakage: 0.2

Performance Standards:

  • Meets IECC 2012
  • Meets IECC 2009

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface4.5 - 8.36.4

Install Uninsulated Ducts:

Before-Component After-Component Cost

None

Properties:

  • Insulation Nominal R-Value: h-ft^2-R/Btu
  • Total Leakage:

Lifetime:

  • Years
 

20% Leakage, R-8

Properties:

  • Insulation Nominal R-Value: 8.0 h-ft^2-R/Btu
  • Total Leakage: 0.2

Performance Standards:

  • Exceeds IECC 2009
  • Exceeds IECC 2012

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface4.6 - 8.46.5

Install Uninsulated Ducts (Total Leakage):

Before-Component After-Component Cost

None

Properties:

  • Insulation Nominal R-Value: h-ft^2-R/Btu
  • Total Leakage:

Lifetime:

  • Years
 

20% Leakage, Uninsulated

Properties:

  • Insulation Nominal R-Value: 0.0 h-ft^2-R/Btu
  • Total Leakage: 0.2

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface3.5 - 6.14.8

Install Uninsulated Ducts:

Before-Component After-Component Cost

None

Properties:

  • Insulation Nominal R-Value: h-ft^2-R/Btu
  • Total Leakage:

Lifetime:

  • Years
 

30% Leakage, R-4

Properties:

  • Insulation Nominal R-Value: 4.0 h-ft^2-R/Btu
  • Total Leakage: 0.3

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface3.7 - 7.95.8

Install Uninsulated Ducts:

Before-Component After-Component Cost

None

Properties:

  • Insulation Nominal R-Value: h-ft^2-R/Btu
  • Total Leakage:

Lifetime:

  • Years
 

30% Leakage, R-6

Properties:

  • Insulation Nominal R-Value: 6.0 h-ft^2-R/Btu
  • Total Leakage: 0.3

Performance Standards:

  • Meets IECC 2012
  • Meets IECC 2009

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface3.7 - 85.9

Install Uninsulated Ducts:

Before-Component After-Component Cost

None

Properties:

  • Insulation Nominal R-Value: h-ft^2-R/Btu
  • Total Leakage:

Lifetime:

  • Years
 

30% Leakage, R-8

Properties:

  • Insulation Nominal R-Value: 8.0 h-ft^2-R/Btu
  • Total Leakage: 0.3

Performance Standards:

  • Exceeds IECC 2009
  • Exceeds IECC 2012

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface3.8 - 8.15.9

Install Uninsulated Ducts (Total Leakage):

Before-Component After-Component Cost

None

Properties:

  • Insulation Nominal R-Value: h-ft^2-R/Btu
  • Total Leakage:

Lifetime:

  • Years
 

30% Leakage, Uninsulated

Properties:

  • Insulation Nominal R-Value: 0.0 h-ft^2-R/Btu
  • Total Leakage: 0.3

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface2.8 - 5.84.3

Install Uninsulated Ducts:

Before-Component After-Component Cost

None

Properties:

  • Insulation Nominal R-Value: h-ft^2-R/Btu
  • Total Leakage:

Lifetime:

  • Years
 

7.5% Leakage, R-4

Properties:

  • Insulation Nominal R-Value: 4.0 h-ft^2-R/Btu
  • Total Leakage: 0.075

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface5.4 - 8.67

Install Uninsulated Ducts:

Before-Component After-Component Cost

None

Properties:

  • Insulation Nominal R-Value: h-ft^2-R/Btu
  • Total Leakage:

Lifetime:

  • Years
 

7.5% Leakage, R-6

Properties:

  • Insulation Nominal R-Value: 6.0 h-ft^2-R/Btu
  • Total Leakage: 0.075

Performance Standards:

  • Meets IECC 2009
  • Meets IECC 2012

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface5.4 - 8.77.1

Install Uninsulated Ducts:

Before-Component After-Component Cost

None

Properties:

  • Insulation Nominal R-Value: h-ft^2-R/Btu
  • Total Leakage:

Lifetime:

  • Years
 

7.5% Leakage, R-8

Properties:

  • Insulation Nominal R-Value: 8.0 h-ft^2-R/Btu
  • Total Leakage: 0.075

Performance Standards:

  • Exceeds IECC 2012
  • Exceeds IECC 2009

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface5.5 - 8.87.1

Install Uninsulated Ducts (Total Leakage):

Before-Component After-Component Cost

None

Properties:

  • Insulation Nominal R-Value: h-ft^2-R/Btu
  • Total Leakage:

Lifetime:

  • Years
 

7.5% Leakage, Uninsulated

Properties:

  • Insulation Nominal R-Value: 0.0 h-ft^2-R/Btu
  • Total Leakage: 0.075

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Duct Surface4.5 - 6.55.5

Version: v3.1.0