Skip to content National Residential Efficiency Measures Database National Renewable Energy Laboratory

Submit Questions/Comments

Retrofit Measures for Air Source Heat Pump

Here you will find the data for Air Source Heat Pump measures available in the National Residential Efficiency Measures Database. Each measure consists of a before-component, an after-component, and the estimated cost to implement the measure. The measures are listed alphabetically based upon the name of the before-component. Where multiple costs are indicated they must be combined to obtain total measure cost (e.g., fixed ($) and normalized ($/sf) costs).

Cost Drivers

There are many factors that influence the ultimate cost of Air Source Heat Pump measures. The application of the average measure costs displayed below to any particular home is discouraged. Examples of the kinds of issues that can influence the cost of Air Source Heat Pump measures include:
  • Prevailing local wages
  • Drive time
  • Local code requirements
  • Access
  • Need for condensate line/drain
  • Condition of existing electrical system
  • Need for additional wiring/switching
  • Condition of existing duct system
  • Type of equipment

Viewing 103 Air Source Heat Pump Measure(s) of 103

Install Central Heat Pump:

Before-Component After-Component Cost

None

Properties:

  • Rated HSPF: Btu/W-h
  • Rated SEER: Btu/W-h

Lifetime:

  • Years
 

SEER 13, 7.7 HSPF

Properties:

  • Rated HSPF: 7.7 Btu/W-h
  • Rated SEER: 13.0 Btu/W-h

Performance Standards:

  • Meets Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh25 - 5542
$/unit2100 - 45003400

Install Central Heat Pump:

Before-Component After-Component Cost

None

Properties:

  • Rated HSPF: Btu/W-h
  • Rated SEER: Btu/W-h

Lifetime:

  • Years
 

SEER 14, 8.2 HSPF

Properties:

  • Rated HSPF: 8.2 Btu/W-h
  • Rated SEER: 14.0 Btu/W-h

Performance Standards:

  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh25 - 5542
$/unit2100 - 47003600

Install Central Heat Pump:

Before-Component After-Component Cost

None

Properties:

  • Rated HSPF: Btu/W-h
  • Rated SEER: Btu/W-h

Lifetime:

  • Years
 

SEER 15, 8.5 HSPF

Properties:

  • Rated HSPF: 8.5 Btu/W-h
  • Rated SEER: 15.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh25 - 5542
$/unit2200 - 48003700

Install Central Heat Pump:

Before-Component After-Component Cost

None

Properties:

  • Rated HSPF: Btu/W-h
  • Rated SEER: Btu/W-h

Lifetime:

  • Years
 

SEER 16, 8.6 HSPF

Properties:

  • Rated HSPF: 8.6 Btu/W-h
  • Rated SEER: 16.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit2300 - 50003900
$/kBtuh25 - 5542

Install Central Heat Pump:

Before-Component After-Component Cost

None

Properties:

  • Rated HSPF: Btu/W-h
  • Rated SEER: Btu/W-h

Lifetime:

  • Years
 

SEER 17, 8.7 HSPF

Properties:

  • Rated HSPF: 8.7 Btu/W-h
  • Rated SEER: 17.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit2400 - 52004000
$/kBtuh25 - 5542

Install Central Heat Pump:

Before-Component After-Component Cost

None

Properties:

  • Rated HSPF: Btu/W-h
  • Rated SEER: Btu/W-h

Lifetime:

  • Years
 

SEER 18, 9.3 HSPF

Properties:

  • Rated HSPF: 9.3 Btu/W-h
  • Rated SEER: 18.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit2500 - 54004200
$/kBtuh25 - 5542

Install Central Heat Pump:

Before-Component After-Component Cost

None

Properties:

  • Rated HSPF: Btu/W-h
  • Rated SEER: Btu/W-h

Lifetime:

  • Years
 

SEER 19, 9.5 HSPF

Properties:

  • Rated HSPF: 9.5 Btu/W-h
  • Rated SEER: 19.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit2600 - 56004300
$/kBtuh25 - 5542

Install Central Heat Pump:

Before-Component After-Component Cost

None

Properties:

  • Rated HSPF: Btu/W-h
  • Rated SEER: Btu/W-h

Lifetime:

  • Years
 

SEER 20, 10 HSPF

Properties:

  • Rated HSPF: 10.0 Btu/W-h
  • Rated SEER: 20.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh25 - 5542
$/unit2700 - 58004500

Install Central Heat Pump:

Before-Component After-Component Cost

None

Properties:

  • Rated HSPF: Btu/W-h
  • Rated SEER: Btu/W-h

Lifetime:

  • Years
 

SEER 21, 10 HSPF

Properties:

  • Rated HSPF: 10.0 Btu/W-h
  • Rated SEER: 21.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh25 - 5542
$/unit2800 - 60004600

Remove Central Heat Pump:

Before-Component After-Component Cost

SEER 10, 6.2 HSPF

Properties:

  • Rated HSPF: 6.2 Btu/W-h
  • Rated SEER: 10.0 Btu/W-h

Lifetime:

  • 15 Years
 

None

Properties:

  • Rated HSPF: Btu/W-h
  • Rated SEER: Btu/W-h

Lifetime:

  • Years
 

Measure Cost

UnitsRangeAverage
$/unit250 - 550420

Replace Central Heat Pump:

Before-Component After-Component Cost

SEER 10, 6.2 HSPF

Properties:

  • Rated HSPF: 6.2 Btu/W-h
  • Rated SEER: 10.0 Btu/W-h

Lifetime:

  • 15 Years
 

SEER 13, 7.7 HSPF

Properties:

  • Rated HSPF: 7.7 Btu/W-h
  • Rated SEER: 13.0 Btu/W-h

Performance Standards:

  • Meets Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh25 - 5542
$/unit1800 - 39003000

Replace Central Heat Pump:

Before-Component After-Component Cost

SEER 10, 6.2 HSPF

Properties:

  • Rated HSPF: 6.2 Btu/W-h
  • Rated SEER: 10.0 Btu/W-h

Lifetime:

  • 15 Years
 

SEER 14, 8.2 HSPF

Properties:

  • Rated HSPF: 8.2 Btu/W-h
  • Rated SEER: 14.0 Btu/W-h

Performance Standards:

  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit1900 - 41003100
$/kBtuh25 - 5542

Replace Central Heat Pump:

Before-Component After-Component Cost

SEER 10, 6.2 HSPF

Properties:

  • Rated HSPF: 6.2 Btu/W-h
  • Rated SEER: 10.0 Btu/W-h

Lifetime:

  • 15 Years
 

SEER 15, 8.5 HSPF

Properties:

  • Rated HSPF: 8.5 Btu/W-h
  • Rated SEER: 15.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit2000 - 43003300
$/kBtuh25 - 5542

Replace Central Heat Pump:

Before-Component After-Component Cost

SEER 10, 6.2 HSPF

Properties:

  • Rated HSPF: 6.2 Btu/W-h
  • Rated SEER: 10.0 Btu/W-h

Lifetime:

  • 15 Years
 

SEER 16, 8.6 HSPF

Properties:

  • Rated HSPF: 8.6 Btu/W-h
  • Rated SEER: 16.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh25 - 5542
$/unit2100 - 45003400

Replace Central Heat Pump:

Before-Component After-Component Cost

SEER 10, 6.2 HSPF

Properties:

  • Rated HSPF: 6.2 Btu/W-h
  • Rated SEER: 10.0 Btu/W-h

Lifetime:

  • 15 Years
 

SEER 17, 8.7 HSPF

Properties:

  • Rated HSPF: 8.7 Btu/W-h
  • Rated SEER: 17.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh25 - 5542
$/unit2100 - 47003600

Replace Central Heat Pump:

Before-Component After-Component Cost

SEER 10, 6.2 HSPF

Properties:

  • Rated HSPF: 6.2 Btu/W-h
  • Rated SEER: 10.0 Btu/W-h

Lifetime:

  • 15 Years
 

SEER 18, 9.3 HSPF

Properties:

  • Rated HSPF: 9.3 Btu/W-h
  • Rated SEER: 18.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh25 - 5542
$/unit2200 - 48003700

Replace Central Heat Pump:

Before-Component After-Component Cost

SEER 10, 6.2 HSPF

Properties:

  • Rated HSPF: 6.2 Btu/W-h
  • Rated SEER: 10.0 Btu/W-h

Lifetime:

  • 15 Years
 

SEER 19, 9.5 HSPF

Properties:

  • Rated HSPF: 9.5 Btu/W-h
  • Rated SEER: 19.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh25 - 5542
$/unit2300 - 50003900

Replace Central Heat Pump:

Before-Component After-Component Cost

SEER 10, 6.2 HSPF

Properties:

  • Rated HSPF: 6.2 Btu/W-h
  • Rated SEER: 10.0 Btu/W-h

Lifetime:

  • 15 Years
 

SEER 20, 10 HSPF

Properties:

  • Rated HSPF: 10.0 Btu/W-h
  • Rated SEER: 20.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh25 - 5542
$/unit2400 - 52004000

Replace Central Heat Pump:

Before-Component After-Component Cost

SEER 10, 6.2 HSPF

Properties:

  • Rated HSPF: 6.2 Btu/W-h
  • Rated SEER: 10.0 Btu/W-h

Lifetime:

  • 15 Years
 

SEER 21, 10 HSPF

Properties:

  • Rated HSPF: 10.0 Btu/W-h
  • Rated SEER: 21.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh25 - 5542
$/unit2500 - 54004200

Remove Central Heat Pump:

Before-Component After-Component Cost

SEER 11, 6.7 HSPF

Properties:

  • Rated HSPF: 6.7 Btu/W-h
  • Rated SEER: 11.0 Btu/W-h

Lifetime:

  • 15 Years
 

None

Properties:

  • Rated HSPF: Btu/W-h
  • Rated SEER: Btu/W-h

Lifetime:

  • Years
 

Measure Cost

UnitsRangeAverage
$/unit250 - 550420

Replace Central Heat Pump:

Before-Component After-Component Cost

SEER 11, 6.7 HSPF

Properties:

  • Rated HSPF: 6.7 Btu/W-h
  • Rated SEER: 11.0 Btu/W-h

Lifetime:

  • 15 Years
 

SEER 13, 7.7 HSPF

Properties:

  • Rated HSPF: 7.7 Btu/W-h
  • Rated SEER: 13.0 Btu/W-h

Performance Standards:

  • Meets Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit1800 - 39003000
$/kBtuh25 - 5542

Replace Central Heat Pump:

Before-Component After-Component Cost

SEER 11, 6.7 HSPF

Properties:

  • Rated HSPF: 6.7 Btu/W-h
  • Rated SEER: 11.0 Btu/W-h

Lifetime:

  • 15 Years
 

SEER 14, 8.2 HSPF

Properties:

  • Rated HSPF: 8.2 Btu/W-h
  • Rated SEER: 14.0 Btu/W-h

Performance Standards:

  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit1900 - 41003100
$/kBtuh25 - 5542

Replace Central Heat Pump:

Before-Component After-Component Cost

SEER 11, 6.7 HSPF

Properties:

  • Rated HSPF: 6.7 Btu/W-h
  • Rated SEER: 11.0 Btu/W-h

Lifetime:

  • 15 Years
 

SEER 15, 8.5 HSPF

Properties:

  • Rated HSPF: 8.5 Btu/W-h
  • Rated SEER: 15.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh25 - 5542
$/unit2000 - 43003300

Replace Central Heat Pump:

Before-Component After-Component Cost

SEER 11, 6.7 HSPF

Properties:

  • Rated HSPF: 6.7 Btu/W-h
  • Rated SEER: 11.0 Btu/W-h

Lifetime:

  • 15 Years
 

SEER 16, 8.6 HSPF

Properties:

  • Rated HSPF: 8.6 Btu/W-h
  • Rated SEER: 16.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh25 - 5542
$/unit2100 - 45003400

Replace Central Heat Pump:

Before-Component After-Component Cost

SEER 11, 6.7 HSPF

Properties:

  • Rated HSPF: 6.7 Btu/W-h
  • Rated SEER: 11.0 Btu/W-h

Lifetime:

  • 15 Years
 

SEER 17, 8.7 HSPF

Properties:

  • Rated HSPF: 8.7 Btu/W-h
  • Rated SEER: 17.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh25 - 5542
$/unit2100 - 47003600

Replace Central Heat Pump:

Before-Component After-Component Cost

SEER 11, 6.7 HSPF

Properties:

  • Rated HSPF: 6.7 Btu/W-h
  • Rated SEER: 11.0 Btu/W-h

Lifetime:

  • 15 Years
 

SEER 18, 9.3 HSPF

Properties:

  • Rated HSPF: 9.3 Btu/W-h
  • Rated SEER: 18.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh25 - 5542
$/unit2200 - 48003700

Replace Central Heat Pump:

Before-Component After-Component Cost

SEER 11, 6.7 HSPF

Properties:

  • Rated HSPF: 6.7 Btu/W-h
  • Rated SEER: 11.0 Btu/W-h

Lifetime:

  • 15 Years
 

SEER 19, 9.5 HSPF

Properties:

  • Rated HSPF: 9.5 Btu/W-h
  • Rated SEER: 19.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit2300 - 50003900
$/kBtuh25 - 5542

Replace Central Heat Pump:

Before-Component After-Component Cost

SEER 11, 6.7 HSPF

Properties:

  • Rated HSPF: 6.7 Btu/W-h
  • Rated SEER: 11.0 Btu/W-h

Lifetime:

  • 15 Years
 

SEER 20, 10 HSPF

Properties:

  • Rated HSPF: 10.0 Btu/W-h
  • Rated SEER: 20.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh25 - 5542
$/unit2400 - 52004000

Replace Central Heat Pump:

Before-Component After-Component Cost

SEER 11, 6.7 HSPF

Properties:

  • Rated HSPF: 6.7 Btu/W-h
  • Rated SEER: 11.0 Btu/W-h

Lifetime:

  • 15 Years
 

SEER 21, 10 HSPF

Properties:

  • Rated HSPF: 10.0 Btu/W-h
  • Rated SEER: 21.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh25 - 5542
$/unit2500 - 54004200

Remove Central Heat Pump:

Before-Component After-Component Cost

SEER 12, 7.2 HSPF

Properties:

  • Rated HSPF: 7.2 Btu/W-h
  • Rated SEER: 12.0 Btu/W-h

Lifetime:

  • 15 Years
 

None

Properties:

  • Rated HSPF: Btu/W-h
  • Rated SEER: Btu/W-h

Lifetime:

  • Years
 

Measure Cost

UnitsRangeAverage
$/unit250 - 550420

Replace Central Heat Pump:

Before-Component After-Component Cost

SEER 12, 7.2 HSPF

Properties:

  • Rated HSPF: 7.2 Btu/W-h
  • Rated SEER: 12.0 Btu/W-h

Lifetime:

  • 15 Years
 

SEER 13, 7.7 HSPF

Properties:

  • Rated HSPF: 7.7 Btu/W-h
  • Rated SEER: 13.0 Btu/W-h

Performance Standards:

  • Meets Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh25 - 5542
$/unit1800 - 39003000

Replace Central Heat Pump:

Before-Component After-Component Cost

SEER 12, 7.2 HSPF

Properties:

  • Rated HSPF: 7.2 Btu/W-h
  • Rated SEER: 12.0 Btu/W-h

Lifetime:

  • 15 Years
 

SEER 14, 8.2 HSPF

Properties:

  • Rated HSPF: 8.2 Btu/W-h
  • Rated SEER: 14.0 Btu/W-h

Performance Standards:

  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh25 - 5542
$/unit1900 - 41003100

Replace Central Heat Pump:

Before-Component After-Component Cost

SEER 12, 7.2 HSPF

Properties:

  • Rated HSPF: 7.2 Btu/W-h
  • Rated SEER: 12.0 Btu/W-h

Lifetime:

  • 15 Years
 

SEER 15, 8.5 HSPF

Properties:

  • Rated HSPF: 8.5 Btu/W-h
  • Rated SEER: 15.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh25 - 5542
$/unit2000 - 43003300

Replace Central Heat Pump:

Before-Component After-Component Cost

SEER 12, 7.2 HSPF

Properties:

  • Rated HSPF: 7.2 Btu/W-h
  • Rated SEER: 12.0 Btu/W-h

Lifetime:

  • 15 Years
 

SEER 16, 8.6 HSPF

Properties:

  • Rated HSPF: 8.6 Btu/W-h
  • Rated SEER: 16.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit2100 - 45003400
$/kBtuh25 - 5542

Replace Central Heat Pump:

Before-Component After-Component Cost

SEER 12, 7.2 HSPF

Properties:

  • Rated HSPF: 7.2 Btu/W-h
  • Rated SEER: 12.0 Btu/W-h

Lifetime:

  • 15 Years
 

SEER 17, 8.7 HSPF

Properties:

  • Rated HSPF: 8.7 Btu/W-h
  • Rated SEER: 17.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh25 - 5542
$/unit2100 - 47003600

Replace Central Heat Pump:

Before-Component After-Component Cost

SEER 12, 7.2 HSPF

Properties:

  • Rated HSPF: 7.2 Btu/W-h
  • Rated SEER: 12.0 Btu/W-h

Lifetime:

  • 15 Years
 

SEER 18, 9.3 HSPF

Properties:

  • Rated HSPF: 9.3 Btu/W-h
  • Rated SEER: 18.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh25 - 5542
$/unit2200 - 48003700

Replace Central Heat Pump:

Before-Component After-Component Cost

SEER 12, 7.2 HSPF

Properties:

  • Rated HSPF: 7.2 Btu/W-h
  • Rated SEER: 12.0 Btu/W-h

Lifetime:

  • 15 Years
 

SEER 19, 9.5 HSPF

Properties:

  • Rated HSPF: 9.5 Btu/W-h
  • Rated SEER: 19.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit2300 - 50003900
$/kBtuh25 - 5542

Replace Central Heat Pump:

Before-Component After-Component Cost

SEER 12, 7.2 HSPF

Properties:

  • Rated HSPF: 7.2 Btu/W-h
  • Rated SEER: 12.0 Btu/W-h

Lifetime:

  • 15 Years
 

SEER 20, 10 HSPF

Properties:

  • Rated HSPF: 10.0 Btu/W-h
  • Rated SEER: 20.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit2400 - 52004000
$/kBtuh25 - 5542

Replace Central Heat Pump:

Before-Component After-Component Cost

SEER 12, 7.2 HSPF

Properties:

  • Rated HSPF: 7.2 Btu/W-h
  • Rated SEER: 12.0 Btu/W-h

Lifetime:

  • 15 Years
 

SEER 21, 10 HSPF

Properties:

  • Rated HSPF: 10.0 Btu/W-h
  • Rated SEER: 21.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit2500 - 54004200
$/kBtuh25 - 5542

Remove Central Heat Pump:

Before-Component After-Component Cost

SEER 13, 7.7 HSPF

Properties:

  • Rated HSPF: 7.7 Btu/W-h
  • Rated SEER: 13.0 Btu/W-h

Performance Standards:

  • Meets Federal Standard 2006

Lifetime:

  • 15 Years
 

None

Properties:

  • Rated HSPF: Btu/W-h
  • Rated SEER: Btu/W-h

Lifetime:

  • Years
 

Measure Cost

UnitsRangeAverage
$/unit250 - 550420

Replace Central Heat Pump:

Before-Component After-Component Cost

SEER 13, 7.7 HSPF

Properties:

  • Rated HSPF: 7.7 Btu/W-h
  • Rated SEER: 13.0 Btu/W-h

Performance Standards:

  • Meets Federal Standard 2006

Lifetime:

  • 15 Years
 

SEER 13, 7.7 HSPF

Properties:

  • Rated HSPF: 7.7 Btu/W-h
  • Rated SEER: 13.0 Btu/W-h

Performance Standards:

  • Meets Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh25 - 5542
$/unit1800 - 39003000

Replace Central Heat Pump:

Before-Component After-Component Cost

SEER 13, 7.7 HSPF

Properties:

  • Rated HSPF: 7.7 Btu/W-h
  • Rated SEER: 13.0 Btu/W-h

Performance Standards:

  • Meets Federal Standard 2006

Lifetime:

  • 15 Years
 

SEER 14, 8.2 HSPF

Properties:

  • Rated HSPF: 8.2 Btu/W-h
  • Rated SEER: 14.0 Btu/W-h

Performance Standards:

  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh25 - 5542
$/unit1900 - 41003100

Replace Central Heat Pump:

Before-Component After-Component Cost

SEER 13, 7.7 HSPF

Properties:

  • Rated HSPF: 7.7 Btu/W-h
  • Rated SEER: 13.0 Btu/W-h

Performance Standards:

  • Meets Federal Standard 2006

Lifetime:

  • 15 Years
 

SEER 15, 8.5 HSPF

Properties:

  • Rated HSPF: 8.5 Btu/W-h
  • Rated SEER: 15.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit2000 - 43003300
$/kBtuh25 - 5542

Replace Central Heat Pump:

Before-Component After-Component Cost

SEER 13, 7.7 HSPF

Properties:

  • Rated HSPF: 7.7 Btu/W-h
  • Rated SEER: 13.0 Btu/W-h

Performance Standards:

  • Meets Federal Standard 2006

Lifetime:

  • 15 Years
 

SEER 16, 8.6 HSPF

Properties:

  • Rated HSPF: 8.6 Btu/W-h
  • Rated SEER: 16.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit2100 - 45003400
$/kBtuh25 - 5542

Replace Central Heat Pump:

Before-Component After-Component Cost

SEER 13, 7.7 HSPF

Properties:

  • Rated HSPF: 7.7 Btu/W-h
  • Rated SEER: 13.0 Btu/W-h

Performance Standards:

  • Meets Federal Standard 2006

Lifetime:

  • 15 Years
 

SEER 17, 8.7 HSPF

Properties:

  • Rated HSPF: 8.7 Btu/W-h
  • Rated SEER: 17.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit2100 - 47003600
$/kBtuh25 - 5542

Replace Central Heat Pump:

Before-Component After-Component Cost

SEER 13, 7.7 HSPF

Properties:

  • Rated HSPF: 7.7 Btu/W-h
  • Rated SEER: 13.0 Btu/W-h

Performance Standards:

  • Meets Federal Standard 2006

Lifetime:

  • 15 Years
 

SEER 18, 9.3 HSPF

Properties:

  • Rated HSPF: 9.3 Btu/W-h
  • Rated SEER: 18.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh25 - 5542
$/unit2200 - 48003700

Replace Central Heat Pump:

Before-Component After-Component Cost

SEER 13, 7.7 HSPF

Properties:

  • Rated HSPF: 7.7 Btu/W-h
  • Rated SEER: 13.0 Btu/W-h

Performance Standards:

  • Meets Federal Standard 2006

Lifetime:

  • 15 Years
 

SEER 19, 9.5 HSPF

Properties:

  • Rated HSPF: 9.5 Btu/W-h
  • Rated SEER: 19.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit2300 - 50003900
$/kBtuh25 - 5542

Replace Central Heat Pump:

Before-Component After-Component Cost

SEER 13, 7.7 HSPF

Properties:

  • Rated HSPF: 7.7 Btu/W-h
  • Rated SEER: 13.0 Btu/W-h

Performance Standards:

  • Meets Federal Standard 2006

Lifetime:

  • 15 Years
 

SEER 20, 10 HSPF

Properties:

  • Rated HSPF: 10.0 Btu/W-h
  • Rated SEER: 20.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit2400 - 52004000
$/kBtuh25 - 5542

Replace Central Heat Pump:

Before-Component After-Component Cost

SEER 13, 7.7 HSPF

Properties:

  • Rated HSPF: 7.7 Btu/W-h
  • Rated SEER: 13.0 Btu/W-h

Performance Standards:

  • Meets Federal Standard 2006

Lifetime:

  • 15 Years
 

SEER 21, 10 HSPF

Properties:

  • Rated HSPF: 10.0 Btu/W-h
  • Rated SEER: 21.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit2500 - 54004200
$/kBtuh25 - 5542

Remove Central Heat Pump:

Before-Component After-Component Cost

SEER 14, 8.2 HSPF

Properties:

  • Rated HSPF: 8.2 Btu/W-h
  • Rated SEER: 14.0 Btu/W-h

Performance Standards:

  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

None

Properties:

  • Rated HSPF: Btu/W-h
  • Rated SEER: Btu/W-h

Lifetime:

  • Years
 

Measure Cost

UnitsRangeAverage
$/unit250 - 550420

Replace Central Heat Pump:

Before-Component After-Component Cost

SEER 14, 8.2 HSPF

Properties:

  • Rated HSPF: 8.2 Btu/W-h
  • Rated SEER: 14.0 Btu/W-h

Performance Standards:

  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

SEER 14, 8.2 HSPF

Properties:

  • Rated HSPF: 8.2 Btu/W-h
  • Rated SEER: 14.0 Btu/W-h

Performance Standards:

  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh25 - 5542
$/unit1900 - 41003100

Replace Central Heat Pump:

Before-Component After-Component Cost

SEER 14, 8.2 HSPF

Properties:

  • Rated HSPF: 8.2 Btu/W-h
  • Rated SEER: 14.0 Btu/W-h

Performance Standards:

  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

SEER 15, 8.5 HSPF

Properties:

  • Rated HSPF: 8.5 Btu/W-h
  • Rated SEER: 15.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit2000 - 43003300
$/kBtuh25 - 5542

Replace Central Heat Pump:

Before-Component After-Component Cost

SEER 14, 8.2 HSPF

Properties:

  • Rated HSPF: 8.2 Btu/W-h
  • Rated SEER: 14.0 Btu/W-h

Performance Standards:

  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

SEER 16, 8.6 HSPF

Properties:

  • Rated HSPF: 8.6 Btu/W-h
  • Rated SEER: 16.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit2100 - 45003400
$/kBtuh25 - 5542

Replace Central Heat Pump:

Before-Component After-Component Cost

SEER 14, 8.2 HSPF

Properties:

  • Rated HSPF: 8.2 Btu/W-h
  • Rated SEER: 14.0 Btu/W-h

Performance Standards:

  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

SEER 17, 8.7 HSPF

Properties:

  • Rated HSPF: 8.7 Btu/W-h
  • Rated SEER: 17.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh25 - 5542
$/unit2100 - 47003600

Replace Central Heat Pump:

Before-Component After-Component Cost

SEER 14, 8.2 HSPF

Properties:

  • Rated HSPF: 8.2 Btu/W-h
  • Rated SEER: 14.0 Btu/W-h

Performance Standards:

  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

SEER 18, 9.3 HSPF

Properties:

  • Rated HSPF: 9.3 Btu/W-h
  • Rated SEER: 18.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh25 - 5542
$/unit2200 - 48003700

Replace Central Heat Pump:

Before-Component After-Component Cost

SEER 14, 8.2 HSPF

Properties:

  • Rated HSPF: 8.2 Btu/W-h
  • Rated SEER: 14.0 Btu/W-h

Performance Standards:

  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

SEER 19, 9.5 HSPF

Properties:

  • Rated HSPF: 9.5 Btu/W-h
  • Rated SEER: 19.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh25 - 5542
$/unit2300 - 50003900

Replace Central Heat Pump:

Before-Component After-Component Cost

SEER 14, 8.2 HSPF

Properties:

  • Rated HSPF: 8.2 Btu/W-h
  • Rated SEER: 14.0 Btu/W-h

Performance Standards:

  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

SEER 20, 10 HSPF

Properties:

  • Rated HSPF: 10.0 Btu/W-h
  • Rated SEER: 20.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh25 - 5542
$/unit2400 - 52004000

Replace Central Heat Pump:

Before-Component After-Component Cost

SEER 14, 8.2 HSPF

Properties:

  • Rated HSPF: 8.2 Btu/W-h
  • Rated SEER: 14.0 Btu/W-h

Performance Standards:

  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

SEER 21, 10 HSPF

Properties:

  • Rated HSPF: 10.0 Btu/W-h
  • Rated SEER: 21.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh25 - 5542
$/unit2500 - 54004200

Remove Central Heat Pump:

Before-Component After-Component Cost

SEER 15, 8.5 HSPF

Properties:

  • Rated HSPF: 8.5 Btu/W-h
  • Rated SEER: 15.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

None

Properties:

  • Rated HSPF: Btu/W-h
  • Rated SEER: Btu/W-h

Lifetime:

  • Years
 

Measure Cost

UnitsRangeAverage
$/unit250 - 550420

Replace Central Heat Pump:

Before-Component After-Component Cost

SEER 15, 8.5 HSPF

Properties:

  • Rated HSPF: 8.5 Btu/W-h
  • Rated SEER: 15.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

SEER 15, 8.5 HSPF

Properties:

  • Rated HSPF: 8.5 Btu/W-h
  • Rated SEER: 15.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh25 - 5542
$/unit2000 - 43003300

Replace Central Heat Pump:

Before-Component After-Component Cost

SEER 15, 8.5 HSPF

Properties:

  • Rated HSPF: 8.5 Btu/W-h
  • Rated SEER: 15.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

SEER 16, 8.6 HSPF

Properties:

  • Rated HSPF: 8.6 Btu/W-h
  • Rated SEER: 16.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh25 - 5542
$/unit2100 - 45003400

Replace Central Heat Pump:

Before-Component After-Component Cost

SEER 15, 8.5 HSPF

Properties:

  • Rated HSPF: 8.5 Btu/W-h
  • Rated SEER: 15.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

SEER 17, 8.7 HSPF

Properties:

  • Rated HSPF: 8.7 Btu/W-h
  • Rated SEER: 17.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit2100 - 47003600
$/kBtuh25 - 5542

Replace Central Heat Pump:

Before-Component After-Component Cost

SEER 15, 8.5 HSPF

Properties:

  • Rated HSPF: 8.5 Btu/W-h
  • Rated SEER: 15.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

SEER 18, 9.3 HSPF

Properties:

  • Rated HSPF: 9.3 Btu/W-h
  • Rated SEER: 18.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit2200 - 48003700
$/kBtuh25 - 5542

Replace Central Heat Pump:

Before-Component After-Component Cost

SEER 15, 8.5 HSPF

Properties:

  • Rated HSPF: 8.5 Btu/W-h
  • Rated SEER: 15.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

SEER 19, 9.5 HSPF

Properties:

  • Rated HSPF: 9.5 Btu/W-h
  • Rated SEER: 19.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit2300 - 50003900
$/kBtuh25 - 5542

Replace Central Heat Pump:

Before-Component After-Component Cost

SEER 15, 8.5 HSPF

Properties:

  • Rated HSPF: 8.5 Btu/W-h
  • Rated SEER: 15.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

SEER 20, 10 HSPF

Properties:

  • Rated HSPF: 10.0 Btu/W-h
  • Rated SEER: 20.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh25 - 5542
$/unit2400 - 52004000

Replace Central Heat Pump:

Before-Component After-Component Cost

SEER 15, 8.5 HSPF

Properties:

  • Rated HSPF: 8.5 Btu/W-h
  • Rated SEER: 15.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

SEER 21, 10 HSPF

Properties:

  • Rated HSPF: 10.0 Btu/W-h
  • Rated SEER: 21.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit2500 - 54004200
$/kBtuh25 - 5542

Remove Central Heat Pump:

Before-Component After-Component Cost

SEER 16, 8.6 HSPF

Properties:

  • Rated HSPF: 8.6 Btu/W-h
  • Rated SEER: 16.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

None

Properties:

  • Rated HSPF: Btu/W-h
  • Rated SEER: Btu/W-h

Lifetime:

  • Years
 

Measure Cost

UnitsRangeAverage
$/unit250 - 550420

Replace Central Heat Pump:

Before-Component After-Component Cost

SEER 16, 8.6 HSPF

Properties:

  • Rated HSPF: 8.6 Btu/W-h
  • Rated SEER: 16.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

SEER 16, 8.6 HSPF

Properties:

  • Rated HSPF: 8.6 Btu/W-h
  • Rated SEER: 16.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit2100 - 45003400
$/kBtuh25 - 5542

Replace Central Heat Pump:

Before-Component After-Component Cost

SEER 16, 8.6 HSPF

Properties:

  • Rated HSPF: 8.6 Btu/W-h
  • Rated SEER: 16.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

SEER 17, 8.7 HSPF

Properties:

  • Rated HSPF: 8.7 Btu/W-h
  • Rated SEER: 17.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit2100 - 47003600
$/kBtuh25 - 5542

Replace Central Heat Pump:

Before-Component After-Component Cost

SEER 16, 8.6 HSPF

Properties:

  • Rated HSPF: 8.6 Btu/W-h
  • Rated SEER: 16.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

SEER 18, 9.3 HSPF

Properties:

  • Rated HSPF: 9.3 Btu/W-h
  • Rated SEER: 18.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit2200 - 48003700
$/kBtuh25 - 5542

Replace Central Heat Pump:

Before-Component After-Component Cost

SEER 16, 8.6 HSPF

Properties:

  • Rated HSPF: 8.6 Btu/W-h
  • Rated SEER: 16.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

SEER 19, 9.5 HSPF

Properties:

  • Rated HSPF: 9.5 Btu/W-h
  • Rated SEER: 19.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit2300 - 50003900
$/kBtuh25 - 5542

Replace Central Heat Pump:

Before-Component After-Component Cost

SEER 16, 8.6 HSPF

Properties:

  • Rated HSPF: 8.6 Btu/W-h
  • Rated SEER: 16.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

SEER 20, 10 HSPF

Properties:

  • Rated HSPF: 10.0 Btu/W-h
  • Rated SEER: 20.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh25 - 5542
$/unit2400 - 52004000

Replace Central Heat Pump:

Before-Component After-Component Cost

SEER 16, 8.6 HSPF

Properties:

  • Rated HSPF: 8.6 Btu/W-h
  • Rated SEER: 16.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

SEER 21, 10 HSPF

Properties:

  • Rated HSPF: 10.0 Btu/W-h
  • Rated SEER: 21.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit2500 - 54004200
$/kBtuh25 - 5542

Remove Central Heat Pump:

Before-Component After-Component Cost

SEER 17, 8.7 HSPF

Properties:

  • Rated HSPF: 8.7 Btu/W-h
  • Rated SEER: 17.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

None

Properties:

  • Rated HSPF: Btu/W-h
  • Rated SEER: Btu/W-h

Lifetime:

  • Years
 

Measure Cost

UnitsRangeAverage
$/unit250 - 550420

Replace Central Heat Pump:

Before-Component After-Component Cost

SEER 17, 8.7 HSPF

Properties:

  • Rated HSPF: 8.7 Btu/W-h
  • Rated SEER: 17.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

SEER 17, 8.7 HSPF

Properties:

  • Rated HSPF: 8.7 Btu/W-h
  • Rated SEER: 17.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh25 - 5542
$/unit2100 - 47003600

Replace Central Heat Pump:

Before-Component After-Component Cost

SEER 17, 8.7 HSPF

Properties:

  • Rated HSPF: 8.7 Btu/W-h
  • Rated SEER: 17.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

SEER 18, 9.3 HSPF

Properties:

  • Rated HSPF: 9.3 Btu/W-h
  • Rated SEER: 18.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit2200 - 48003700
$/kBtuh25 - 5542

Replace Central Heat Pump:

Before-Component After-Component Cost

SEER 17, 8.7 HSPF

Properties:

  • Rated HSPF: 8.7 Btu/W-h
  • Rated SEER: 17.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

SEER 19, 9.5 HSPF

Properties:

  • Rated HSPF: 9.5 Btu/W-h
  • Rated SEER: 19.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh25 - 5542
$/unit2300 - 50003900

Replace Central Heat Pump:

Before-Component After-Component Cost

SEER 17, 8.7 HSPF

Properties:

  • Rated HSPF: 8.7 Btu/W-h
  • Rated SEER: 17.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

SEER 20, 10 HSPF

Properties:

  • Rated HSPF: 10.0 Btu/W-h
  • Rated SEER: 20.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit2400 - 52004000
$/kBtuh25 - 5542

Replace Central Heat Pump:

Before-Component After-Component Cost

SEER 17, 8.7 HSPF

Properties:

  • Rated HSPF: 8.7 Btu/W-h
  • Rated SEER: 17.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

SEER 21, 10 HSPF

Properties:

  • Rated HSPF: 10.0 Btu/W-h
  • Rated SEER: 21.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh25 - 5542
$/unit2500 - 54004200

Remove Central Heat Pump:

Before-Component After-Component Cost

SEER 18, 9.3 HSPF

Properties:

  • Rated HSPF: 9.3 Btu/W-h
  • Rated SEER: 18.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

None

Properties:

  • Rated HSPF: Btu/W-h
  • Rated SEER: Btu/W-h

Lifetime:

  • Years
 

Measure Cost

UnitsRangeAverage
$/unit250 - 550420

Replace Central Heat Pump:

Before-Component After-Component Cost

SEER 18, 9.3 HSPF

Properties:

  • Rated HSPF: 9.3 Btu/W-h
  • Rated SEER: 18.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

SEER 18, 9.3 HSPF

Properties:

  • Rated HSPF: 9.3 Btu/W-h
  • Rated SEER: 18.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh25 - 5542
$/unit2200 - 48003700

Replace Central Heat Pump:

Before-Component After-Component Cost

SEER 18, 9.3 HSPF

Properties:

  • Rated HSPF: 9.3 Btu/W-h
  • Rated SEER: 18.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

SEER 19, 9.5 HSPF

Properties:

  • Rated HSPF: 9.5 Btu/W-h
  • Rated SEER: 19.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit2300 - 50003900
$/kBtuh25 - 5542

Replace Central Heat Pump:

Before-Component After-Component Cost

SEER 18, 9.3 HSPF

Properties:

  • Rated HSPF: 9.3 Btu/W-h
  • Rated SEER: 18.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

SEER 20, 10 HSPF

Properties:

  • Rated HSPF: 10.0 Btu/W-h
  • Rated SEER: 20.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit2400 - 52004000
$/kBtuh25 - 5542

Replace Central Heat Pump:

Before-Component After-Component Cost

SEER 18, 9.3 HSPF

Properties:

  • Rated HSPF: 9.3 Btu/W-h
  • Rated SEER: 18.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

SEER 21, 10 HSPF

Properties:

  • Rated HSPF: 10.0 Btu/W-h
  • Rated SEER: 21.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh25 - 5542
$/unit2500 - 54004200

Remove Central Heat Pump:

Before-Component After-Component Cost

SEER 19, 9.5 HSPF

Properties:

  • Rated HSPF: 9.5 Btu/W-h
  • Rated SEER: 19.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

None

Properties:

  • Rated HSPF: Btu/W-h
  • Rated SEER: Btu/W-h

Lifetime:

  • Years
 

Measure Cost

UnitsRangeAverage
$/unit250 - 550420

Replace Central Heat Pump:

Before-Component After-Component Cost

SEER 19, 9.5 HSPF

Properties:

  • Rated HSPF: 9.5 Btu/W-h
  • Rated SEER: 19.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

SEER 19, 9.5 HSPF

Properties:

  • Rated HSPF: 9.5 Btu/W-h
  • Rated SEER: 19.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit2300 - 50003900
$/kBtuh25 - 5542

Replace Central Heat Pump:

Before-Component After-Component Cost

SEER 19, 9.5 HSPF

Properties:

  • Rated HSPF: 9.5 Btu/W-h
  • Rated SEER: 19.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

SEER 20, 10 HSPF

Properties:

  • Rated HSPF: 10.0 Btu/W-h
  • Rated SEER: 20.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit2400 - 52004000
$/kBtuh25 - 5542

Replace Central Heat Pump:

Before-Component After-Component Cost

SEER 19, 9.5 HSPF

Properties:

  • Rated HSPF: 9.5 Btu/W-h
  • Rated SEER: 19.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

SEER 21, 10 HSPF

Properties:

  • Rated HSPF: 10.0 Btu/W-h
  • Rated SEER: 21.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh25 - 5542
$/unit2500 - 54004200

Remove Central Heat Pump:

Before-Component After-Component Cost

SEER 20, 10 HSPF

Properties:

  • Rated HSPF: 10.0 Btu/W-h
  • Rated SEER: 20.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

None

Properties:

  • Rated HSPF: Btu/W-h
  • Rated SEER: Btu/W-h

Lifetime:

  • Years
 

Measure Cost

UnitsRangeAverage
$/unit250 - 550420

Replace Central Heat Pump:

Before-Component After-Component Cost

SEER 20, 10 HSPF

Properties:

  • Rated HSPF: 10.0 Btu/W-h
  • Rated SEER: 20.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

SEER 20, 10 HSPF

Properties:

  • Rated HSPF: 10.0 Btu/W-h
  • Rated SEER: 20.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh25 - 5542
$/unit2400 - 52004000

Replace Central Heat Pump:

Before-Component After-Component Cost

SEER 20, 10 HSPF

Properties:

  • Rated HSPF: 10.0 Btu/W-h
  • Rated SEER: 20.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

SEER 21, 10 HSPF

Properties:

  • Rated HSPF: 10.0 Btu/W-h
  • Rated SEER: 21.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh25 - 5542
$/unit2500 - 54004200

Remove Central Heat Pump:

Before-Component After-Component Cost

SEER 21, 10 HSPF

Properties:

  • Rated HSPF: 10.0 Btu/W-h
  • Rated SEER: 21.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

None

Properties:

  • Rated HSPF: Btu/W-h
  • Rated SEER: Btu/W-h

Lifetime:

  • Years
 

Measure Cost

UnitsRangeAverage
$/unit250 - 550420

Replace Central Heat Pump:

Before-Component After-Component Cost

SEER 21, 10 HSPF

Properties:

  • Rated HSPF: 10.0 Btu/W-h
  • Rated SEER: 21.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

SEER 21, 10 HSPF

Properties:

  • Rated HSPF: 10.0 Btu/W-h
  • Rated SEER: 21.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit2500 - 54004200
$/kBtuh25 - 5542

Remove Central Heat Pump:

Before-Component After-Component Cost

SEER 8, 6.0 HSPF

Properties:

  • Rated HSPF: 6.0 Btu/W-h
  • Rated SEER: 8.0 Btu/W-h

Lifetime:

  • 15 Years
 

None

Properties:

  • Rated HSPF: Btu/W-h
  • Rated SEER: Btu/W-h

Lifetime:

  • Years
 

Measure Cost

UnitsRangeAverage
$/unit250 - 550420

Replace Central Heat Pump:

Before-Component After-Component Cost

SEER 8, 6.0 HSPF

Properties:

  • Rated HSPF: 6.0 Btu/W-h
  • Rated SEER: 8.0 Btu/W-h

Lifetime:

  • 15 Years
 

SEER 13, 7.7 HSPF

Properties:

  • Rated HSPF: 7.7 Btu/W-h
  • Rated SEER: 13.0 Btu/W-h

Performance Standards:

  • Meets Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh25 - 5542
$/unit1800 - 39003000

Replace Central Heat Pump:

Before-Component After-Component Cost

SEER 8, 6.0 HSPF

Properties:

  • Rated HSPF: 6.0 Btu/W-h
  • Rated SEER: 8.0 Btu/W-h

Lifetime:

  • 15 Years
 

SEER 14, 8.2 HSPF

Properties:

  • Rated HSPF: 8.2 Btu/W-h
  • Rated SEER: 14.0 Btu/W-h

Performance Standards:

  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit1900 - 41003100
$/kBtuh25 - 5542

Replace Central Heat Pump:

Before-Component After-Component Cost

SEER 8, 6.0 HSPF

Properties:

  • Rated HSPF: 6.0 Btu/W-h
  • Rated SEER: 8.0 Btu/W-h

Lifetime:

  • 15 Years
 

SEER 15, 8.5 HSPF

Properties:

  • Rated HSPF: 8.5 Btu/W-h
  • Rated SEER: 15.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh25 - 5542
$/unit2000 - 43003300

Replace Central Heat Pump:

Before-Component After-Component Cost

SEER 8, 6.0 HSPF

Properties:

  • Rated HSPF: 6.0 Btu/W-h
  • Rated SEER: 8.0 Btu/W-h

Lifetime:

  • 15 Years
 

SEER 16, 8.6 HSPF

Properties:

  • Rated HSPF: 8.6 Btu/W-h
  • Rated SEER: 16.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh25 - 5542
$/unit2100 - 45003400

Replace Central Heat Pump:

Before-Component After-Component Cost

SEER 8, 6.0 HSPF

Properties:

  • Rated HSPF: 6.0 Btu/W-h
  • Rated SEER: 8.0 Btu/W-h

Lifetime:

  • 15 Years
 

SEER 17, 8.7 HSPF

Properties:

  • Rated HSPF: 8.7 Btu/W-h
  • Rated SEER: 17.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh25 - 5542
$/unit2100 - 47003600

Replace Central Heat Pump:

Before-Component After-Component Cost

SEER 8, 6.0 HSPF

Properties:

  • Rated HSPF: 6.0 Btu/W-h
  • Rated SEER: 8.0 Btu/W-h

Lifetime:

  • 15 Years
 

SEER 18, 9.3 HSPF

Properties:

  • Rated HSPF: 9.3 Btu/W-h
  • Rated SEER: 18.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit2200 - 48003700
$/kBtuh25 - 5542

Replace Central Heat Pump:

Before-Component After-Component Cost

SEER 8, 6.0 HSPF

Properties:

  • Rated HSPF: 6.0 Btu/W-h
  • Rated SEER: 8.0 Btu/W-h

Lifetime:

  • 15 Years
 

SEER 19, 9.5 HSPF

Properties:

  • Rated HSPF: 9.5 Btu/W-h
  • Rated SEER: 19.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh25 - 5542
$/unit2300 - 50003900

Replace Central Heat Pump:

Before-Component After-Component Cost

SEER 8, 6.0 HSPF

Properties:

  • Rated HSPF: 6.0 Btu/W-h
  • Rated SEER: 8.0 Btu/W-h

Lifetime:

  • 15 Years
 

SEER 20, 10 HSPF

Properties:

  • Rated HSPF: 10.0 Btu/W-h
  • Rated SEER: 20.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh25 - 5542
$/unit2400 - 52004000

Replace Central Heat Pump:

Before-Component After-Component Cost

SEER 8, 6.0 HSPF

Properties:

  • Rated HSPF: 6.0 Btu/W-h
  • Rated SEER: 8.0 Btu/W-h

Lifetime:

  • 15 Years
 

SEER 21, 10 HSPF

Properties:

  • Rated HSPF: 10.0 Btu/W-h
  • Rated SEER: 21.0 Btu/W-h

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit2500 - 54004200
$/kBtuh25 - 5542