Skip to content National Residential Efficiency Measures Database National Renewable Energy Laboratory

Submit Questions/Comments

Retrofit Measures for Furnace

Here you will find the data for Furnace measures available in the National Residential Efficiency Measures Database. Each measure consists of a before-component, an after-component, and the estimated cost to implement the measure. The measures are listed alphabetically based upon the name of the before-component. Where multiple costs are indicated they must be combined to obtain total measure cost (e.g., fixed ($) and normalized ($/sf) costs).

Cost Drivers

There are many factors that influence the ultimate cost of Furnace measures. The application of the average measure costs displayed below to any particular home is discouraged. Examples of the kinds of issues that can influence the cost of Furnace measures include:
  • Prevailing local wages
  • Drive time
  • Local code requirements
  • Access
  • Condition of existing flue
  • Need to bring in combustion air
  • Condition of existing electrical system
  • Need for additional wiring/switching
  • Condition of existing gas line
  • Presence of hazardous materials
  • Stand alone vs treating both heating/cooling
  • Need for controls and/or zoning
  • Condition of existing duct system
  • Type of equipment

Viewing 793 Furnace Measure(s) of 793

Replace Furnace:

Before-Component After-Component Cost

Electric, 100% AFUE

Properties:

  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 1.0 Btu/Btu

Lifetime:

  • 20 Years
 

Electric, 100% AFUE

Properties:

  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 1.0 Btu/Btu

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit1000 - 21001600
$/kBtuh Input35 - 6550

Replace Furnace:

Before-Component After-Component Cost

Electric, 100% AFUE

Properties:

  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 1.0 Btu/Btu

Lifetime:

  • 20 Years
 

Gas, 78% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input1.9 - 3.52.7
$/unit1200 - 24001800

Replace Furnace:

Before-Component After-Component Cost

Electric, 100% AFUE

Properties:

  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 1.0 Btu/Btu

Lifetime:

  • 20 Years
 

Gas, 80% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Meets Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit1200 - 24001900
$/kBtuh Input1.9 - 3.52.7

Replace Furnace:

Before-Component After-Component Cost

Electric, 100% AFUE

Properties:

  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 1.0 Btu/Btu

Lifetime:

  • 20 Years
 

Gas, 90% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.9 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit1300 - 27002100
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Electric, 100% AFUE

Properties:

  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 1.0 Btu/Btu

Lifetime:

  • 20 Years
 

Gas, 92.5% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.925 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit1500 - 30002300
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Electric, 100% AFUE

Properties:

  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 1.0 Btu/Btu

Lifetime:

  • 20 Years
 

Gas, 95% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.95 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit1700 - 33002500
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Electric, 100% AFUE

Properties:

  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 1.0 Btu/Btu

Lifetime:

  • 20 Years
 

Gas, 96% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.96 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit1700 - 34002600
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Electric, 100% AFUE

Properties:

  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 1.0 Btu/Btu

Lifetime:

  • 20 Years
 

Gas, 98% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.98 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit1900 - 36002800
$/kBtuh Input2.7 - 53.9

Remove Furnace:

Before-Component After-Component Cost

Electric, 100% AFUE

Properties:

  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 1.0 Btu/Btu

Lifetime:

  • 20 Years
 

None

Properties:

  • Fuel Type:
  • Max Supply Temp: degrees F
  • Rated AFUE: Btu/Btu

Lifetime:

  • Years
 

Measure Cost

UnitsRangeAverage
$/unit140 - 300230

Replace Furnace:

Before-Component After-Component Cost

Electric, 100% AFUE

Properties:

  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 1.0 Btu/Btu

Lifetime:

  • 20 Years
 

Oil, 78% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input1.9 - 3.52.7
$/unit970 - 20001500

Replace Furnace:

Before-Component After-Component Cost

Electric, 100% AFUE

Properties:

  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 1.0 Btu/Btu

Lifetime:

  • 20 Years
 

Oil, 80% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit1100 - 23001800
$/kBtuh Input1.9 - 3.52.7

Replace Furnace:

Before-Component After-Component Cost

Electric, 100% AFUE

Properties:

  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 1.0 Btu/Btu

Lifetime:

  • 20 Years
 

Oil, 85% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.85 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit1600 - 32002500
$/kBtuh Input1.9 - 3.52.7

Replace Furnace:

Before-Component After-Component Cost

Electric, 100% AFUE

Properties:

  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 1.0 Btu/Btu

Lifetime:

  • 20 Years
 

Oil, 90% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.9 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit2100 - 40003100
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Electric, 100% AFUE

Properties:

  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 1.0 Btu/Btu

Lifetime:

  • 20 Years
 

Oil, 94% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.94 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit2600 - 51003900
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Electric, 100% AFUE

Properties:

  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 1.0 Btu/Btu

Lifetime:

  • 20 Years
 

Oil, 95% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.95 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Exceeds Energy Star 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit2800 - 53004100

Replace Furnace:

Before-Component After-Component Cost

Electric, 100% AFUE

Properties:

  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 1.0 Btu/Btu

Lifetime:

  • 20 Years
 

Oil, 96% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.96 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.3 - 53.9
$/unit2600 - 56004300

Replace Furnace:

Before-Component After-Component Cost

Electric, 100% AFUE

Properties:

  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 1.0 Btu/Btu

Lifetime:

  • 20 Years
 

Propane, 78% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit970 - 20001500
$/kBtuh Input1.9 - 3.52.7

Replace Furnace:

Before-Component After-Component Cost

Electric, 100% AFUE

Properties:

  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 1.0 Btu/Btu

Lifetime:

  • 20 Years
 

Propane, 80% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit1100 - 23001800
$/kBtuh Input1.9 - 3.52.7

Replace Furnace:

Before-Component After-Component Cost

Electric, 100% AFUE

Properties:

  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 1.0 Btu/Btu

Lifetime:

  • 20 Years
 

Propane, 82% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.82 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input1.9 - 3.52.7
$/unit1300 - 27002100

Replace Furnace:

Before-Component After-Component Cost

Electric, 100% AFUE

Properties:

  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 1.0 Btu/Btu

Lifetime:

  • 20 Years
 

Propane, 90% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.9 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit2100 - 40003100

Replace Furnace:

Before-Component After-Component Cost

Electric, 100% AFUE

Properties:

  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 1.0 Btu/Btu

Lifetime:

  • 20 Years
 

Propane, 92% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.92 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit2300 - 45003400

Replace Furnace:

Before-Component After-Component Cost

Electric, 100% AFUE

Properties:

  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 1.0 Btu/Btu

Lifetime:

  • 20 Years
 

Propane, 94% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.94 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit2500 - 49003800
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Electric, 100% AFUE

Properties:

  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 1.0 Btu/Btu

Lifetime:

  • 20 Years
 

Propane, 95% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.95 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Electric, 100% AFUE

Properties:

  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 1.0 Btu/Btu

Lifetime:

  • 20 Years
 

Propane, 96% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.96 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit2800 - 53004100
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Gas, 60% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.6 Btu/Btu

Lifetime:

  • 20 Years
 

Electric, 100% AFUE

Properties:

  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 1.0 Btu/Btu

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input35 - 6550
$/unit1000 - 21001600

Replace Furnace:

Before-Component After-Component Cost

Gas, 60% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.6 Btu/Btu

Lifetime:

  • 20 Years
 

Gas, 78% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit1200 - 24001800
$/kBtuh Input1.9 - 3.52.7

Replace Furnace:

Before-Component After-Component Cost

Gas, 60% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.6 Btu/Btu

Lifetime:

  • 20 Years
 

Gas, 80% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Meets Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit1200 - 24001900
$/kBtuh Input1.9 - 3.52.7

Replace Furnace:

Before-Component After-Component Cost

Gas, 60% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.6 Btu/Btu

Lifetime:

  • 20 Years
 

Gas, 90% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.9 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit1300 - 27002100
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Gas, 60% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.6 Btu/Btu

Lifetime:

  • 20 Years
 

Gas, 92.5% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.925 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit1500 - 30002300

Replace Furnace:

Before-Component After-Component Cost

Gas, 60% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.6 Btu/Btu

Lifetime:

  • 20 Years
 

Gas, 95% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.95 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit1700 - 33002500

Replace Furnace:

Before-Component After-Component Cost

Gas, 60% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.6 Btu/Btu

Lifetime:

  • 20 Years
 

Gas, 96% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.96 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit1700 - 34002600

Replace Furnace:

Before-Component After-Component Cost

Gas, 60% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.6 Btu/Btu

Lifetime:

  • 20 Years
 

Gas, 98% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.98 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit1900 - 36002800
$/kBtuh Input2.7 - 53.9

Remove Furnace:

Before-Component After-Component Cost

Gas, 60% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.6 Btu/Btu

Lifetime:

  • 20 Years
 

None

Properties:

  • Fuel Type:
  • Max Supply Temp: degrees F
  • Rated AFUE: Btu/Btu

Lifetime:

  • Years
 

Measure Cost

UnitsRangeAverage
$/unit140 - 300230

Replace Furnace:

Before-Component After-Component Cost

Gas, 60% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.6 Btu/Btu

Lifetime:

  • 20 Years
 

Oil, 78% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit970 - 20001500
$/kBtuh Input1.9 - 3.52.7

Replace Furnace:

Before-Component After-Component Cost

Gas, 60% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.6 Btu/Btu

Lifetime:

  • 20 Years
 

Oil, 80% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit1100 - 23001800
$/kBtuh Input1.9 - 3.52.7

Replace Furnace:

Before-Component After-Component Cost

Gas, 60% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.6 Btu/Btu

Lifetime:

  • 20 Years
 

Oil, 85% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.85 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit1600 - 32002500
$/kBtuh Input1.9 - 3.52.7

Replace Furnace:

Before-Component After-Component Cost

Gas, 60% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.6 Btu/Btu

Lifetime:

  • 20 Years
 

Oil, 90% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.9 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit2100 - 40003100

Replace Furnace:

Before-Component After-Component Cost

Gas, 60% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.6 Btu/Btu

Lifetime:

  • 20 Years
 

Oil, 94% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.94 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit2600 - 51003900
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Gas, 60% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.6 Btu/Btu

Lifetime:

  • 20 Years
 

Oil, 95% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.95 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Exceeds Energy Star 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit2800 - 53004100

Replace Furnace:

Before-Component After-Component Cost

Gas, 60% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.6 Btu/Btu

Lifetime:

  • 20 Years
 

Oil, 96% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.96 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.3 - 53.9
$/unit2600 - 56004300

Replace Furnace:

Before-Component After-Component Cost

Gas, 60% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.6 Btu/Btu

Lifetime:

  • 20 Years
 

Propane, 78% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input1.9 - 3.52.7
$/unit970 - 20001500

Replace Furnace:

Before-Component After-Component Cost

Gas, 60% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.6 Btu/Btu

Lifetime:

  • 20 Years
 

Propane, 80% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit1100 - 23001800
$/kBtuh Input1.9 - 3.52.7

Replace Furnace:

Before-Component After-Component Cost

Gas, 60% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.6 Btu/Btu

Lifetime:

  • 20 Years
 

Propane, 82% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.82 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit1300 - 27002100
$/kBtuh Input1.9 - 3.52.7

Replace Furnace:

Before-Component After-Component Cost

Gas, 60% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.6 Btu/Btu

Lifetime:

  • 20 Years
 

Propane, 90% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.9 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit2100 - 40003100

Replace Furnace:

Before-Component After-Component Cost

Gas, 60% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.6 Btu/Btu

Lifetime:

  • 20 Years
 

Propane, 92% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.92 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit2300 - 45003400
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Gas, 60% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.6 Btu/Btu

Lifetime:

  • 20 Years
 

Propane, 94% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.94 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit2500 - 49003800
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Gas, 60% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.6 Btu/Btu

Lifetime:

  • 20 Years
 

Propane, 95% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.95 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 60% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.6 Btu/Btu

Lifetime:

  • 20 Years
 

Propane, 96% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.96 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit2800 - 53004100
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Gas, 64% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.64 Btu/Btu

Lifetime:

  • 20 Years
 

Electric, 100% AFUE

Properties:

  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 1.0 Btu/Btu

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input35 - 6550
$/unit1000 - 21001600

Replace Furnace:

Before-Component After-Component Cost

Gas, 64% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.64 Btu/Btu

Lifetime:

  • 20 Years
 

Gas, 78% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input1.9 - 3.52.7
$/unit1200 - 24001800

Replace Furnace:

Before-Component After-Component Cost

Gas, 64% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.64 Btu/Btu

Lifetime:

  • 20 Years
 

Gas, 80% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Meets Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit1200 - 24001900
$/kBtuh Input1.9 - 3.52.7

Replace Furnace:

Before-Component After-Component Cost

Gas, 64% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.64 Btu/Btu

Lifetime:

  • 20 Years
 

Gas, 90% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.9 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit1300 - 27002100

Replace Furnace:

Before-Component After-Component Cost

Gas, 64% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.64 Btu/Btu

Lifetime:

  • 20 Years
 

Gas, 92.5% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.925 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit1500 - 30002300

Replace Furnace:

Before-Component After-Component Cost

Gas, 64% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.64 Btu/Btu

Lifetime:

  • 20 Years
 

Gas, 95% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.95 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit1700 - 33002500

Replace Furnace:

Before-Component After-Component Cost

Gas, 64% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.64 Btu/Btu

Lifetime:

  • 20 Years
 

Gas, 96% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.96 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit1700 - 34002600

Replace Furnace:

Before-Component After-Component Cost

Gas, 64% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.64 Btu/Btu

Lifetime:

  • 20 Years
 

Gas, 98% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.98 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit1900 - 36002800

Remove Furnace:

Before-Component After-Component Cost

Gas, 64% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.64 Btu/Btu

Lifetime:

  • 20 Years
 

None

Properties:

  • Fuel Type:
  • Max Supply Temp: degrees F
  • Rated AFUE: Btu/Btu

Lifetime:

  • Years
 

Measure Cost

UnitsRangeAverage
$/unit140 - 300230

Replace Furnace:

Before-Component After-Component Cost

Gas, 64% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.64 Btu/Btu

Lifetime:

  • 20 Years
 

Oil, 78% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit970 - 20001500
$/kBtuh Input1.9 - 3.52.7

Replace Furnace:

Before-Component After-Component Cost

Gas, 64% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.64 Btu/Btu

Lifetime:

  • 20 Years
 

Oil, 80% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit1100 - 23001800
$/kBtuh Input1.9 - 3.52.7

Replace Furnace:

Before-Component After-Component Cost

Gas, 64% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.64 Btu/Btu

Lifetime:

  • 20 Years
 

Oil, 85% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.85 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit1600 - 32002500
$/kBtuh Input1.9 - 3.52.7

Replace Furnace:

Before-Component After-Component Cost

Gas, 64% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.64 Btu/Btu

Lifetime:

  • 20 Years
 

Oil, 90% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.9 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit2100 - 40003100
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Gas, 64% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.64 Btu/Btu

Lifetime:

  • 20 Years
 

Oil, 94% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.94 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit2600 - 51003900

Replace Furnace:

Before-Component After-Component Cost

Gas, 64% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.64 Btu/Btu

Lifetime:

  • 20 Years
 

Oil, 95% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.95 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Exceeds Energy Star 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit2800 - 53004100

Replace Furnace:

Before-Component After-Component Cost

Gas, 64% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.64 Btu/Btu

Lifetime:

  • 20 Years
 

Oil, 96% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.96 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.3 - 53.9
$/unit2600 - 56004300

Replace Furnace:

Before-Component After-Component Cost

Gas, 64% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.64 Btu/Btu

Lifetime:

  • 20 Years
 

Propane, 78% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input1.9 - 3.52.7
$/unit970 - 20001500

Replace Furnace:

Before-Component After-Component Cost

Gas, 64% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.64 Btu/Btu

Lifetime:

  • 20 Years
 

Propane, 80% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input1.9 - 3.52.7
$/unit1100 - 23001800

Replace Furnace:

Before-Component After-Component Cost

Gas, 64% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.64 Btu/Btu

Lifetime:

  • 20 Years
 

Propane, 82% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.82 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit1300 - 27002100
$/kBtuh Input1.9 - 3.52.7

Replace Furnace:

Before-Component After-Component Cost

Gas, 64% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.64 Btu/Btu

Lifetime:

  • 20 Years
 

Propane, 90% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.9 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit2100 - 40003100

Replace Furnace:

Before-Component After-Component Cost

Gas, 64% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.64 Btu/Btu

Lifetime:

  • 20 Years
 

Propane, 92% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.92 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit2300 - 45003400
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Gas, 64% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.64 Btu/Btu

Lifetime:

  • 20 Years
 

Propane, 94% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.94 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit2500 - 49003800
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Gas, 64% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.64 Btu/Btu

Lifetime:

  • 20 Years
 

Propane, 95% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.95 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 64% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.64 Btu/Btu

Lifetime:

  • 20 Years
 

Propane, 96% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.96 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit2800 - 53004100

Replace Furnace:

Before-Component After-Component Cost

Gas, 68% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.68 Btu/Btu

Lifetime:

  • 20 Years
 

Electric, 100% AFUE

Properties:

  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 1.0 Btu/Btu

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input35 - 6550
$/unit1000 - 21001600

Replace Furnace:

Before-Component After-Component Cost

Gas, 68% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.68 Btu/Btu

Lifetime:

  • 20 Years
 

Gas, 78% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit1200 - 24001800
$/kBtuh Input1.9 - 3.52.7

Replace Furnace:

Before-Component After-Component Cost

Gas, 68% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.68 Btu/Btu

Lifetime:

  • 20 Years
 

Gas, 80% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Meets Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input1.9 - 3.52.7
$/unit1200 - 24001900

Replace Furnace:

Before-Component After-Component Cost

Gas, 68% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.68 Btu/Btu

Lifetime:

  • 20 Years
 

Gas, 90% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.9 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit1300 - 27002100
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Gas, 68% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.68 Btu/Btu

Lifetime:

  • 20 Years
 

Gas, 92.5% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.925 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit1500 - 30002300

Replace Furnace:

Before-Component After-Component Cost

Gas, 68% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.68 Btu/Btu

Lifetime:

  • 20 Years
 

Gas, 95% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.95 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit1700 - 33002500
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Gas, 68% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.68 Btu/Btu

Lifetime:

  • 20 Years
 

Gas, 96% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.96 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit1700 - 34002600
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Gas, 68% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.68 Btu/Btu

Lifetime:

  • 20 Years
 

Gas, 98% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.98 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit1900 - 36002800
$/kBtuh Input2.7 - 53.9

Remove Furnace:

Before-Component After-Component Cost

Gas, 68% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.68 Btu/Btu

Lifetime:

  • 20 Years
 

None

Properties:

  • Fuel Type:
  • Max Supply Temp: degrees F
  • Rated AFUE: Btu/Btu

Lifetime:

  • Years
 

Measure Cost

UnitsRangeAverage
$/unit140 - 300230

Replace Furnace:

Before-Component After-Component Cost

Gas, 68% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.68 Btu/Btu

Lifetime:

  • 20 Years
 

Oil, 78% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit970 - 20001500
$/kBtuh Input1.9 - 3.52.7

Replace Furnace:

Before-Component After-Component Cost

Gas, 68% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.68 Btu/Btu

Lifetime:

  • 20 Years
 

Oil, 80% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input1.9 - 3.52.7
$/unit1100 - 23001800

Replace Furnace:

Before-Component After-Component Cost

Gas, 68% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.68 Btu/Btu

Lifetime:

  • 20 Years
 

Oil, 85% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.85 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input1.9 - 3.52.7
$/unit1600 - 32002500

Replace Furnace:

Before-Component After-Component Cost

Gas, 68% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.68 Btu/Btu

Lifetime:

  • 20 Years
 

Oil, 90% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.9 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit2100 - 40003100
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Gas, 68% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.68 Btu/Btu

Lifetime:

  • 20 Years
 

Oil, 94% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.94 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit2600 - 51003900
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Gas, 68% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.68 Btu/Btu

Lifetime:

  • 20 Years
 

Oil, 95% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.95 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Exceeds Energy Star 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit2800 - 53004100
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Gas, 68% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.68 Btu/Btu

Lifetime:

  • 20 Years
 

Oil, 96% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.96 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit2600 - 56004300
$/kBtuh Input2.3 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Gas, 68% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.68 Btu/Btu

Lifetime:

  • 20 Years
 

Propane, 78% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input1.9 - 3.52.7
$/unit970 - 20001500

Replace Furnace:

Before-Component After-Component Cost

Gas, 68% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.68 Btu/Btu

Lifetime:

  • 20 Years
 

Propane, 80% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit1100 - 23001800
$/kBtuh Input1.9 - 3.52.7

Replace Furnace:

Before-Component After-Component Cost

Gas, 68% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.68 Btu/Btu

Lifetime:

  • 20 Years
 

Propane, 82% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.82 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit1300 - 27002100
$/kBtuh Input1.9 - 3.52.7

Replace Furnace:

Before-Component After-Component Cost

Gas, 68% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.68 Btu/Btu

Lifetime:

  • 20 Years
 

Propane, 90% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.9 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit2100 - 40003100

Replace Furnace:

Before-Component After-Component Cost

Gas, 68% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.68 Btu/Btu

Lifetime:

  • 20 Years
 

Propane, 92% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.92 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit2300 - 45003400

Replace Furnace:

Before-Component After-Component Cost

Gas, 68% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.68 Btu/Btu

Lifetime:

  • 20 Years
 

Propane, 94% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.94 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit2500 - 49003800
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Gas, 68% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.68 Btu/Btu

Lifetime:

  • 20 Years
 

Propane, 95% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.95 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 68% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.68 Btu/Btu

Lifetime:

  • 20 Years
 

Propane, 96% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.96 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit2800 - 53004100

Replace Furnace:

Before-Component After-Component Cost

Gas, 72% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.72 Btu/Btu

Lifetime:

  • 20 Years
 

Electric, 100% AFUE

Properties:

  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 1.0 Btu/Btu

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input35 - 6550
$/unit1000 - 21001600

Replace Furnace:

Before-Component After-Component Cost

Gas, 72% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.72 Btu/Btu

Lifetime:

  • 20 Years
 

Gas, 78% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input1.9 - 3.52.7
$/unit1200 - 24001800

Replace Furnace:

Before-Component After-Component Cost

Gas, 72% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.72 Btu/Btu

Lifetime:

  • 20 Years
 

Gas, 80% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Meets Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit1200 - 24001900
$/kBtuh Input1.9 - 3.52.7

Replace Furnace:

Before-Component After-Component Cost

Gas, 72% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.72 Btu/Btu

Lifetime:

  • 20 Years
 

Gas, 90% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.9 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit1300 - 27002100
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Gas, 72% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.72 Btu/Btu

Lifetime:

  • 20 Years
 

Gas, 92.5% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.925 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit1500 - 30002300
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Gas, 72% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.72 Btu/Btu

Lifetime:

  • 20 Years
 

Gas, 95% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.95 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit1700 - 33002500

Replace Furnace:

Before-Component After-Component Cost

Gas, 72% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.72 Btu/Btu

Lifetime:

  • 20 Years
 

Gas, 96% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.96 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit1700 - 34002600
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Gas, 72% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.72 Btu/Btu

Lifetime:

  • 20 Years
 

Gas, 98% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.98 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit1900 - 36002800
$/kBtuh Input2.7 - 53.9

Remove Furnace:

Before-Component After-Component Cost

Gas, 72% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.72 Btu/Btu

Lifetime:

  • 20 Years
 

None

Properties:

  • Fuel Type:
  • Max Supply Temp: degrees F
  • Rated AFUE: Btu/Btu

Lifetime:

  • Years
 

Measure Cost

UnitsRangeAverage
$/unit140 - 300230

Replace Furnace:

Before-Component After-Component Cost

Gas, 72% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.72 Btu/Btu

Lifetime:

  • 20 Years
 

Oil, 78% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input1.9 - 3.52.7
$/unit970 - 20001500

Replace Furnace:

Before-Component After-Component Cost

Gas, 72% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.72 Btu/Btu

Lifetime:

  • 20 Years
 

Oil, 80% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit1100 - 23001800
$/kBtuh Input1.9 - 3.52.7

Replace Furnace:

Before-Component After-Component Cost

Gas, 72% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.72 Btu/Btu

Lifetime:

  • 20 Years
 

Oil, 85% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.85 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input1.9 - 3.52.7
$/unit1600 - 32002500

Replace Furnace:

Before-Component After-Component Cost

Gas, 72% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.72 Btu/Btu

Lifetime:

  • 20 Years
 

Oil, 90% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.9 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit2100 - 40003100
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Gas, 72% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.72 Btu/Btu

Lifetime:

  • 20 Years
 

Oil, 94% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.94 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit2600 - 51003900
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Gas, 72% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.72 Btu/Btu

Lifetime:

  • 20 Years
 

Oil, 95% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.95 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Exceeds Energy Star 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit2800 - 53004100
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Gas, 72% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.72 Btu/Btu

Lifetime:

  • 20 Years
 

Oil, 96% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.96 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit2600 - 56004300
$/kBtuh Input2.3 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Gas, 72% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.72 Btu/Btu

Lifetime:

  • 20 Years
 

Propane, 78% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit970 - 20001500
$/kBtuh Input1.9 - 3.52.7

Replace Furnace:

Before-Component After-Component Cost

Gas, 72% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.72 Btu/Btu

Lifetime:

  • 20 Years
 

Propane, 80% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input1.9 - 3.52.7
$/unit1100 - 23001800

Replace Furnace:

Before-Component After-Component Cost

Gas, 72% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.72 Btu/Btu

Lifetime:

  • 20 Years
 

Propane, 82% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.82 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input1.9 - 3.52.7
$/unit1300 - 27002100

Replace Furnace:

Before-Component After-Component Cost

Gas, 72% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.72 Btu/Btu

Lifetime:

  • 20 Years
 

Propane, 90% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.9 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit2100 - 40003100

Replace Furnace:

Before-Component After-Component Cost

Gas, 72% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.72 Btu/Btu

Lifetime:

  • 20 Years
 

Propane, 92% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.92 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit2300 - 45003400

Replace Furnace:

Before-Component After-Component Cost

Gas, 72% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.72 Btu/Btu

Lifetime:

  • 20 Years
 

Propane, 94% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.94 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit2500 - 49003800
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Gas, 72% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.72 Btu/Btu

Lifetime:

  • 20 Years
 

Propane, 95% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.95 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 72% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.72 Btu/Btu

Lifetime:

  • 20 Years
 

Propane, 96% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.96 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit2800 - 53004100
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Gas, 76% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.76 Btu/Btu

Lifetime:

  • 20 Years
 

Electric, 100% AFUE

Properties:

  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 1.0 Btu/Btu

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input35 - 6550
$/unit1000 - 21001600

Replace Furnace:

Before-Component After-Component Cost

Gas, 76% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.76 Btu/Btu

Lifetime:

  • 20 Years
 

Gas, 78% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input1.9 - 3.52.7
$/unit1200 - 24001800

Replace Furnace:

Before-Component After-Component Cost

Gas, 76% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.76 Btu/Btu

Lifetime:

  • 20 Years
 

Gas, 80% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Meets Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit1200 - 24001900
$/kBtuh Input1.9 - 3.52.7

Replace Furnace:

Before-Component After-Component Cost

Gas, 76% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.76 Btu/Btu

Lifetime:

  • 20 Years
 

Gas, 90% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.9 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit1300 - 27002100
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Gas, 76% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.76 Btu/Btu

Lifetime:

  • 20 Years
 

Gas, 92.5% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.925 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit1500 - 30002300
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Gas, 76% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.76 Btu/Btu

Lifetime:

  • 20 Years
 

Gas, 95% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.95 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit1700 - 33002500

Replace Furnace:

Before-Component After-Component Cost

Gas, 76% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.76 Btu/Btu

Lifetime:

  • 20 Years
 

Gas, 96% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.96 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit1700 - 34002600
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Gas, 76% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.76 Btu/Btu

Lifetime:

  • 20 Years
 

Gas, 98% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.98 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit1900 - 36002800

Remove Furnace:

Before-Component After-Component Cost

Gas, 76% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.76 Btu/Btu

Lifetime:

  • 20 Years
 

None

Properties:

  • Fuel Type:
  • Max Supply Temp: degrees F
  • Rated AFUE: Btu/Btu

Lifetime:

  • Years
 

Measure Cost

UnitsRangeAverage
$/unit140 - 300230

Replace Furnace:

Before-Component After-Component Cost

Gas, 76% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.76 Btu/Btu

Lifetime:

  • 20 Years
 

Oil, 78% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit970 - 20001500
$/kBtuh Input1.9 - 3.52.7

Replace Furnace:

Before-Component After-Component Cost

Gas, 76% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.76 Btu/Btu

Lifetime:

  • 20 Years
 

Oil, 80% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit1100 - 23001800
$/kBtuh Input1.9 - 3.52.7

Replace Furnace:

Before-Component After-Component Cost

Gas, 76% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.76 Btu/Btu

Lifetime:

  • 20 Years
 

Oil, 85% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.85 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit1600 - 32002500
$/kBtuh Input1.9 - 3.52.7

Replace Furnace:

Before-Component After-Component Cost

Gas, 76% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.76 Btu/Btu

Lifetime:

  • 20 Years
 

Oil, 90% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.9 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit2100 - 40003100

Replace Furnace:

Before-Component After-Component Cost

Gas, 76% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.76 Btu/Btu

Lifetime:

  • 20 Years
 

Oil, 94% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.94 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit2600 - 51003900
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Gas, 76% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.76 Btu/Btu

Lifetime:

  • 20 Years
 

Oil, 95% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.95 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Exceeds Energy Star 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit2800 - 53004100
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Gas, 76% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.76 Btu/Btu

Lifetime:

  • 20 Years
 

Oil, 96% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.96 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit2600 - 56004300
$/kBtuh Input2.3 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Gas, 76% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.76 Btu/Btu

Lifetime:

  • 20 Years
 

Propane, 78% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit970 - 20001500
$/kBtuh Input1.9 - 3.52.7

Replace Furnace:

Before-Component After-Component Cost

Gas, 76% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.76 Btu/Btu

Lifetime:

  • 20 Years
 

Propane, 80% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit1100 - 23001800
$/kBtuh Input1.9 - 3.52.7

Replace Furnace:

Before-Component After-Component Cost

Gas, 76% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.76 Btu/Btu

Lifetime:

  • 20 Years
 

Propane, 82% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.82 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input1.9 - 3.52.7
$/unit1300 - 27002100

Replace Furnace:

Before-Component After-Component Cost

Gas, 76% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.76 Btu/Btu

Lifetime:

  • 20 Years
 

Propane, 90% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.9 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit2100 - 40003100
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Gas, 76% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.76 Btu/Btu

Lifetime:

  • 20 Years
 

Propane, 92% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.92 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit2300 - 45003400
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Gas, 76% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.76 Btu/Btu

Lifetime:

  • 20 Years
 

Propane, 94% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.94 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit2500 - 49003800
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Gas, 76% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.76 Btu/Btu

Lifetime:

  • 20 Years
 

Propane, 95% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.95 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 76% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.76 Btu/Btu

Lifetime:

  • 20 Years
 

Propane, 96% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.96 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit2800 - 53004100

Replace Furnace:

Before-Component After-Component Cost

Gas, 78% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Electric, 100% AFUE

Properties:

  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 1.0 Btu/Btu

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit1000 - 21001600
$/kBtuh Input35 - 6550

Replace Furnace:

Before-Component After-Component Cost

Gas, 78% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Gas, 78% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit1200 - 24001800
$/kBtuh Input1.9 - 3.52.7

Replace Furnace:

Before-Component After-Component Cost

Gas, 78% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Gas, 80% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Meets Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit1200 - 24001900
$/kBtuh Input1.9 - 3.52.7

Replace Furnace:

Before-Component After-Component Cost

Gas, 78% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Gas, 90% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.9 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit1300 - 27002100
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Gas, 78% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Gas, 92.5% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.925 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit1500 - 30002300
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Gas, 78% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Gas, 95% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.95 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit1700 - 33002500
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Gas, 78% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Gas, 96% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.96 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit1700 - 34002600
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Gas, 78% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Gas, 98% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.98 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit1900 - 36002800
$/kBtuh Input2.7 - 53.9

Remove Furnace:

Before-Component After-Component Cost

Gas, 78% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

None

Properties:

  • Fuel Type:
  • Max Supply Temp: degrees F
  • Rated AFUE: Btu/Btu

Lifetime:

  • Years
 

Measure Cost

UnitsRangeAverage
$/unit140 - 300230

Replace Furnace:

Before-Component After-Component Cost

Gas, 78% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Oil, 78% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit970 - 20001500
$/kBtuh Input1.9 - 3.52.7

Replace Furnace:

Before-Component After-Component Cost

Gas, 78% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Oil, 80% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit1100 - 23001800
$/kBtuh Input1.9 - 3.52.7

Replace Furnace:

Before-Component After-Component Cost

Gas, 78% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Oil, 85% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.85 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input1.9 - 3.52.7
$/unit1600 - 32002500

Replace Furnace:

Before-Component After-Component Cost

Gas, 78% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Oil, 90% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.9 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit2100 - 40003100
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Gas, 78% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Oil, 94% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.94 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit2600 - 51003900
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Gas, 78% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Oil, 95% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.95 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Exceeds Energy Star 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit2800 - 53004100

Replace Furnace:

Before-Component After-Component Cost

Gas, 78% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Oil, 96% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.96 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit2600 - 56004300
$/kBtuh Input2.3 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Gas, 78% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Propane, 78% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit970 - 20001500
$/kBtuh Input1.9 - 3.52.7

Replace Furnace:

Before-Component After-Component Cost

Gas, 78% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Propane, 80% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit1100 - 23001800
$/kBtuh Input1.9 - 3.52.7

Replace Furnace:

Before-Component After-Component Cost

Gas, 78% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Propane, 82% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.82 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input1.9 - 3.52.7
$/unit1300 - 27002100

Replace Furnace:

Before-Component After-Component Cost

Gas, 78% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Propane, 90% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.9 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit2100 - 40003100
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Gas, 78% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Propane, 92% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.92 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit2300 - 45003400
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Gas, 78% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Propane, 94% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.94 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit2500 - 49003800
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Gas, 78% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Propane, 95% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.95 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 78% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Propane, 96% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.96 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit2800 - 53004100
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Gas, 80% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Meets Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Electric, 100% AFUE

Properties:

  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 1.0 Btu/Btu

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input35 - 6550
$/unit1000 - 21001600

Replace Furnace:

Before-Component After-Component Cost

Gas, 80% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Meets Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Gas, 80% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Meets Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit1200 - 24001900
$/kBtuh Input1.9 - 3.52.7

Replace Furnace:

Before-Component After-Component Cost

Gas, 80% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Meets Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Gas, 90% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.9 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit1300 - 27002100

Replace Furnace:

Before-Component After-Component Cost

Gas, 80% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Meets Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Gas, 92.5% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.925 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit1500 - 30002300

Replace Furnace:

Before-Component After-Component Cost

Gas, 80% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Meets Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Gas, 95% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.95 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit1700 - 33002500
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Gas, 80% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Meets Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Gas, 96% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.96 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit1700 - 34002600
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Gas, 80% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Meets Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Gas, 98% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.98 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit1900 - 36002800
$/kBtuh Input2.7 - 53.9

Remove Furnace:

Before-Component After-Component Cost

Gas, 80% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Meets Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

None

Properties:

  • Fuel Type:
  • Max Supply Temp: degrees F
  • Rated AFUE: Btu/Btu

Lifetime:

  • Years
 

Measure Cost

UnitsRangeAverage
$/unit140 - 300230

Replace Furnace:

Before-Component After-Component Cost

Gas, 80% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Meets Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Oil, 78% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input1.9 - 3.52.7
$/unit970 - 20001500

Replace Furnace:

Before-Component After-Component Cost

Gas, 80% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Meets Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Oil, 80% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input1.9 - 3.52.7
$/unit1100 - 23001800

Replace Furnace:

Before-Component After-Component Cost

Gas, 80% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Meets Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Oil, 85% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.85 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit1600 - 32002500
$/kBtuh Input1.9 - 3.52.7

Replace Furnace:

Before-Component After-Component Cost

Gas, 80% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Meets Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Oil, 90% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.9 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit2100 - 40003100

Replace Furnace:

Before-Component After-Component Cost

Gas, 80% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Meets Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Oil, 94% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.94 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit2600 - 51003900
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Gas, 80% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Meets Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Oil, 95% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.95 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Exceeds Energy Star 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit2800 - 53004100
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Gas, 80% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Meets Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Oil, 96% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.96 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit2600 - 56004300
$/kBtuh Input2.3 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Gas, 80% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Meets Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Propane, 78% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit970 - 20001500
$/kBtuh Input1.9 - 3.52.7

Replace Furnace:

Before-Component After-Component Cost

Gas, 80% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Meets Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Propane, 80% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input1.9 - 3.52.7
$/unit1100 - 23001800

Replace Furnace:

Before-Component After-Component Cost

Gas, 80% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Meets Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Propane, 82% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.82 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit1300 - 27002100
$/kBtuh Input1.9 - 3.52.7

Replace Furnace:

Before-Component After-Component Cost

Gas, 80% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Meets Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Propane, 90% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.9 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit2100 - 40003100
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Gas, 80% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Meets Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Propane, 92% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.92 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit2300 - 45003400

Replace Furnace:

Before-Component After-Component Cost

Gas, 80% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Meets Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Propane, 94% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.94 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit2500 - 49003800

Replace Furnace:

Before-Component After-Component Cost

Gas, 80% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Meets Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Propane, 95% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.95 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 80% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Meets Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Propane, 96% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.96 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit2800 - 53004100
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Gas, 90% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.9 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 20 Years
 

Electric, 100% AFUE

Properties:

  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 1.0 Btu/Btu

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit1000 - 21001600
$/kBtuh Input35 - 6550

Replace Furnace:

Before-Component After-Component Cost

Gas, 90% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.9 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 20 Years
 

Gas, 90% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.9 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit1300 - 27002100
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Gas, 90% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.9 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 20 Years
 

Gas, 92.5% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.925 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit1500 - 30002300
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Gas, 90% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.9 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 20 Years
 

Gas, 95% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.95 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit1700 - 33002500

Replace Furnace:

Before-Component After-Component Cost

Gas, 90% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.9 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 20 Years
 

Gas, 96% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.96 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit1700 - 34002600

Replace Furnace:

Before-Component After-Component Cost

Gas, 90% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.9 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 20 Years
 

Gas, 98% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.98 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit1900 - 36002800
$/kBtuh Input2.7 - 53.9

Remove Furnace:

Before-Component After-Component Cost

Gas, 90% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.9 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 20 Years
 

None

Properties:

  • Fuel Type:
  • Max Supply Temp: degrees F
  • Rated AFUE: Btu/Btu

Lifetime:

  • Years
 

Measure Cost

UnitsRangeAverage
$/unit140 - 300230

Replace Furnace:

Before-Component After-Component Cost

Gas, 90% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.9 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 20 Years
 

Oil, 78% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input1.9 - 3.52.7
$/unit970 - 20001500

Replace Furnace:

Before-Component After-Component Cost

Gas, 90% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.9 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 20 Years
 

Oil, 80% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit1100 - 23001800
$/kBtuh Input1.9 - 3.52.7

Replace Furnace:

Before-Component After-Component Cost

Gas, 90% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.9 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 20 Years
 

Oil, 85% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.85 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit1600 - 32002500
$/kBtuh Input1.9 - 3.52.7

Replace Furnace:

Before-Component After-Component Cost

Gas, 90% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.9 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 20 Years
 

Oil, 90% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.9 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit2100 - 40003100

Replace Furnace:

Before-Component After-Component Cost

Gas, 90% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.9 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 20 Years
 

Oil, 94% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.94 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit2600 - 51003900

Replace Furnace:

Before-Component After-Component Cost

Gas, 90% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.9 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 20 Years
 

Oil, 95% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.95 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Exceeds Energy Star 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit2800 - 53004100
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Gas, 90% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.9 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 20 Years
 

Oil, 96% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.96 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit2600 - 56004300
$/kBtuh Input2.3 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Gas, 90% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.9 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 20 Years
 

Propane, 78% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit970 - 20001500
$/kBtuh Input1.9 - 3.52.7

Replace Furnace:

Before-Component After-Component Cost

Gas, 90% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.9 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 20 Years
 

Propane, 80% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input1.9 - 3.52.7
$/unit1100 - 23001800

Replace Furnace:

Before-Component After-Component Cost

Gas, 90% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.9 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 20 Years
 

Propane, 82% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.82 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input1.9 - 3.52.7
$/unit1300 - 27002100

Replace Furnace:

Before-Component After-Component Cost

Gas, 90% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.9 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 20 Years
 

Propane, 90% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.9 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit2100 - 40003100
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Gas, 90% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.9 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 20 Years
 

Propane, 92% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.92 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit2300 - 45003400

Replace Furnace:

Before-Component After-Component Cost

Gas, 90% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.9 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 20 Years
 

Propane, 94% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.94 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit2500 - 49003800
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Gas, 90% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.9 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 20 Years
 

Propane, 95% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.95 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 90% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.9 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 20 Years
 

Propane, 96% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.96 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit2800 - 53004100

Replace Furnace:

Before-Component After-Component Cost

Gas, 92.5% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.925 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Electric, 100% AFUE

Properties:

  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 1.0 Btu/Btu

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input35 - 6550
$/unit1000 - 21001600

Replace Furnace:

Before-Component After-Component Cost

Gas, 92.5% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.925 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Gas, 92.5% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.925 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit1500 - 30002300

Replace Furnace:

Before-Component After-Component Cost

Gas, 92.5% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.925 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Gas, 95% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.95 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit1700 - 33002500

Replace Furnace:

Before-Component After-Component Cost

Gas, 92.5% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.925 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Gas, 96% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.96 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit1700 - 34002600
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Gas, 92.5% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.925 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Gas, 98% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.98 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit1900 - 36002800

Remove Furnace:

Before-Component After-Component Cost

Gas, 92.5% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.925 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

None

Properties:

  • Fuel Type:
  • Max Supply Temp: degrees F
  • Rated AFUE: Btu/Btu

Lifetime:

  • Years
 

Measure Cost

UnitsRangeAverage
$/unit140 - 300230

Replace Furnace:

Before-Component After-Component Cost

Gas, 92.5% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.925 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Oil, 78% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit970 - 20001500
$/kBtuh Input1.9 - 3.52.7

Replace Furnace:

Before-Component After-Component Cost

Gas, 92.5% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.925 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Oil, 80% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit1100 - 23001800
$/kBtuh Input1.9 - 3.52.7

Replace Furnace:

Before-Component After-Component Cost

Gas, 92.5% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.925 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Oil, 85% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.85 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input1.9 - 3.52.7
$/unit1600 - 32002500

Replace Furnace:

Before-Component After-Component Cost

Gas, 92.5% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.925 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Oil, 90% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.9 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit2100 - 40003100

Replace Furnace:

Before-Component After-Component Cost

Gas, 92.5% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.925 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Oil, 94% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.94 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit2600 - 51003900
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Gas, 92.5% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.925 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Oil, 95% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.95 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Exceeds Energy Star 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit2800 - 53004100
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Gas, 92.5% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.925 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Oil, 96% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.96 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit2600 - 56004300
$/kBtuh Input2.3 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Gas, 92.5% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.925 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Propane, 78% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input1.9 - 3.52.7
$/unit970 - 20001500

Replace Furnace:

Before-Component After-Component Cost

Gas, 92.5% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.925 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Propane, 80% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input1.9 - 3.52.7
$/unit1100 - 23001800

Replace Furnace:

Before-Component After-Component Cost

Gas, 92.5% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.925 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Propane, 82% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.82 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input1.9 - 3.52.7
$/unit1300 - 27002100

Replace Furnace:

Before-Component After-Component Cost

Gas, 92.5% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.925 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Propane, 90% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.9 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit2100 - 40003100
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Gas, 92.5% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.925 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Propane, 92% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.92 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit2300 - 45003400

Replace Furnace:

Before-Component After-Component Cost

Gas, 92.5% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.925 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Propane, 94% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.94 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit2500 - 49003800
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Gas, 92.5% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.925 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Propane, 95% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.95 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 92.5% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.925 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Propane, 96% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.96 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit2800 - 53004100
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Gas, 95% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.95 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Electric, 100% AFUE

Properties:

  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 1.0 Btu/Btu

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit1000 - 21001600
$/kBtuh Input35 - 6550

Replace Furnace:

Before-Component After-Component Cost

Gas, 95% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.95 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Gas, 95% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.95 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit1700 - 33002500
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Gas, 95% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.95 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Gas, 96% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.96 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit1700 - 34002600
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Gas, 95% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.95 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Gas, 98% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.98 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit1900 - 36002800

Remove Furnace:

Before-Component After-Component Cost

Gas, 95% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.95 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

None

Properties:

  • Fuel Type:
  • Max Supply Temp: degrees F
  • Rated AFUE: Btu/Btu

Lifetime:

  • Years
 

Measure Cost

UnitsRangeAverage
$/unit140 - 300230

Replace Furnace:

Before-Component After-Component Cost

Gas, 95% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.95 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Oil, 78% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit970 - 20001500
$/kBtuh Input1.9 - 3.52.7

Replace Furnace:

Before-Component After-Component Cost

Gas, 95% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.95 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Oil, 80% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input1.9 - 3.52.7
$/unit1100 - 23001800

Replace Furnace:

Before-Component After-Component Cost

Gas, 95% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.95 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Oil, 85% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.85 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input1.9 - 3.52.7
$/unit1600 - 32002500

Replace Furnace:

Before-Component After-Component Cost

Gas, 95% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.95 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Oil, 90% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.9 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit2100 - 40003100

Replace Furnace:

Before-Component After-Component Cost

Gas, 95% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.95 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Oil, 94% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.94 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit2600 - 51003900
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Gas, 95% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.95 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Oil, 95% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.95 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Exceeds Energy Star 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit2800 - 53004100
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Gas, 95% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.95 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Oil, 96% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.96 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.3 - 53.9
$/unit2600 - 56004300

Replace Furnace:

Before-Component After-Component Cost

Gas, 95% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.95 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Propane, 78% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit970 - 20001500
$/kBtuh Input1.9 - 3.52.7

Replace Furnace:

Before-Component After-Component Cost

Gas, 95% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.95 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Propane, 80% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input1.9 - 3.52.7
$/unit1100 - 23001800

Replace Furnace:

Before-Component After-Component Cost

Gas, 95% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.95 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Propane, 82% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.82 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit1300 - 27002100
$/kBtuh Input1.9 - 3.52.7

Replace Furnace:

Before-Component After-Component Cost

Gas, 95% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.95 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Propane, 90% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.9 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit2100 - 40003100

Replace Furnace:

Before-Component After-Component Cost

Gas, 95% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.95 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Propane, 92% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.92 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit2300 - 45003400

Replace Furnace:

Before-Component After-Component Cost

Gas, 95% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.95 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Propane, 94% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.94 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit2500 - 49003800
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Gas, 95% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.95 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Propane, 95% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.95 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 95% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.95 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Propane, 96% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.96 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit2800 - 53004100

Replace Furnace:

Before-Component After-Component Cost

Gas, 96% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.96 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Electric, 100% AFUE

Properties:

  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 1.0 Btu/Btu

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input35 - 6550
$/unit1000 - 21001600

Replace Furnace:

Before-Component After-Component Cost

Gas, 96% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.96 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Gas, 96% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.96 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit1700 - 34002600
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Gas, 96% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.96 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Gas, 98% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.98 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit1900 - 36002800

Remove Furnace:

Before-Component After-Component Cost

Gas, 96% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.96 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

None

Properties:

  • Fuel Type:
  • Max Supply Temp: degrees F
  • Rated AFUE: Btu/Btu

Lifetime:

  • Years
 

Measure Cost

UnitsRangeAverage
$/unit140 - 300230

Replace Furnace:

Before-Component After-Component Cost

Gas, 96% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.96 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Oil, 78% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input1.9 - 3.52.7
$/unit970 - 20001500

Replace Furnace:

Before-Component After-Component Cost

Gas, 96% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.96 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Oil, 80% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input1.9 - 3.52.7
$/unit1100 - 23001800

Replace Furnace:

Before-Component After-Component Cost

Gas, 96% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.96 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Oil, 85% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.85 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit1600 - 32002500
$/kBtuh Input1.9 - 3.52.7

Replace Furnace:

Before-Component After-Component Cost

Gas, 96% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.96 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Oil, 90% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.9 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit2100 - 40003100

Replace Furnace:

Before-Component After-Component Cost

Gas, 96% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.96 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Oil, 94% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.94 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit2600 - 51003900
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Gas, 96% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.96 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Oil, 95% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.95 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Exceeds Energy Star 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit2800 - 53004100
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Gas, 96% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.96 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Oil, 96% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.96 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit2600 - 56004300
$/kBtuh Input2.3 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Gas, 96% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.96 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Propane, 78% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input1.9 - 3.52.7
$/unit970 - 20001500

Replace Furnace:

Before-Component After-Component Cost

Gas, 96% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.96 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Propane, 80% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit1100 - 23001800
$/kBtuh Input1.9 - 3.52.7

Replace Furnace:

Before-Component After-Component Cost

Gas, 96% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.96 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Propane, 82% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.82 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input1.9 - 3.52.7
$/unit1300 - 27002100

Replace Furnace:

Before-Component After-Component Cost

Gas, 96% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.96 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Propane, 90% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.9 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit2100 - 40003100

Replace Furnace:

Before-Component After-Component Cost

Gas, 96% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.96 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Propane, 92% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.92 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit2300 - 45003400
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Gas, 96% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.96 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Propane, 94% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.94 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit2500 - 49003800

Replace Furnace:

Before-Component After-Component Cost

Gas, 96% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.96 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Propane, 95% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.95 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 96% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.96 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Propane, 96% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.96 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit2800 - 53004100
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Gas, 98% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.98 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Electric, 100% AFUE

Properties:

  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 1.0 Btu/Btu

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit1000 - 21001600
$/kBtuh Input35 - 6550

Replace Furnace:

Before-Component After-Component Cost

Gas, 98% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.98 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Gas, 98% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.98 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit1900 - 36002800

Remove Furnace:

Before-Component After-Component Cost

Gas, 98% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.98 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

None

Properties:

  • Fuel Type:
  • Max Supply Temp: degrees F
  • Rated AFUE: Btu/Btu

Lifetime:

  • Years
 

Measure Cost

UnitsRangeAverage
$/unit140 - 300230

Replace Furnace:

Before-Component After-Component Cost

Gas, 98% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.98 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Oil, 78% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit970 - 20001500
$/kBtuh Input1.9 - 3.52.7

Replace Furnace:

Before-Component After-Component Cost

Gas, 98% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.98 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Oil, 80% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input1.9 - 3.52.7
$/unit1100 - 23001800

Replace Furnace:

Before-Component After-Component Cost

Gas, 98% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.98 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Oil, 85% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.85 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit1600 - 32002500
$/kBtuh Input1.9 - 3.52.7

Replace Furnace:

Before-Component After-Component Cost

Gas, 98% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.98 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Oil, 90% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.9 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit2100 - 40003100
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Gas, 98% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.98 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Oil, 94% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.94 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit2600 - 51003900
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Gas, 98% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.98 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Oil, 95% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.95 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Exceeds Energy Star 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit2800 - 53004100

Replace Furnace:

Before-Component After-Component Cost

Gas, 98% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.98 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Oil, 96% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.96 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit2600 - 56004300
$/kBtuh Input2.3 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Gas, 98% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.98 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Propane, 78% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input1.9 - 3.52.7
$/unit970 - 20001500

Replace Furnace:

Before-Component After-Component Cost

Gas, 98% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.98 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Propane, 80% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input1.9 - 3.52.7
$/unit1100 - 23001800

Replace Furnace:

Before-Component After-Component Cost

Gas, 98% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.98 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Propane, 82% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.82 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input1.9 - 3.52.7
$/unit1300 - 27002100

Replace Furnace:

Before-Component After-Component Cost

Gas, 98% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.98 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Propane, 90% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.9 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit2100 - 40003100

Replace Furnace:

Before-Component After-Component Cost

Gas, 98% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.98 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Propane, 92% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.92 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit2300 - 45003400
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Gas, 98% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.98 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Propane, 94% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.94 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit2500 - 49003800

Replace Furnace:

Before-Component After-Component Cost

Gas, 98% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.98 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Propane, 95% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.95 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Gas, 98% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.98 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Propane, 96% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.96 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit2800 - 53004100
$/kBtuh Input2.7 - 53.9

Install Furnace:

Before-Component After-Component Cost

None

Properties:

  • Fuel Type:
  • Max Supply Temp: degrees F
  • Rated AFUE: Btu/Btu

Lifetime:

  • Years
 

Electric, 100% AFUE

Properties:

  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 1.0 Btu/Btu

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input35 - 6550
$/unit890 - 18001400

Install Furnace:

Before-Component After-Component Cost

None

Properties:

  • Fuel Type:
  • Max Supply Temp: degrees F
  • Rated AFUE: Btu/Btu

Lifetime:

  • Years
 

Gas, 78% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit1000 - 21001600
$/kBtuh Input1.9 - 3.52.7

Install Furnace:

Before-Component After-Component Cost

None

Properties:

  • Fuel Type:
  • Max Supply Temp: degrees F
  • Rated AFUE: Btu/Btu

Lifetime:

  • Years
 

Gas, 80% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Meets Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input1.9 - 3.52.7
$/unit1100 - 21001600

Install Furnace:

Before-Component After-Component Cost

None

Properties:

  • Fuel Type:
  • Max Supply Temp: degrees F
  • Rated AFUE: Btu/Btu

Lifetime:

  • Years
 

Gas, 90% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.9 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit1200 - 24001800

Install Furnace:

Before-Component After-Component Cost

None

Properties:

  • Fuel Type:
  • Max Supply Temp: degrees F
  • Rated AFUE: Btu/Btu

Lifetime:

  • Years
 

Gas, 92.5% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.925 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit1400 - 27002100

Install Furnace:

Before-Component After-Component Cost

None

Properties:

  • Fuel Type:
  • Max Supply Temp: degrees F
  • Rated AFUE: Btu/Btu

Lifetime:

  • Years
 

Gas, 95% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.95 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit1500 - 30002300
$/kBtuh Input2.7 - 53.9

Install Furnace:

Before-Component After-Component Cost

None

Properties:

  • Fuel Type:
  • Max Supply Temp: degrees F
  • Rated AFUE: Btu/Btu

Lifetime:

  • Years
 

Gas, 96% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.96 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit1600 - 31002400
$/kBtuh Input2.7 - 53.9

Install Furnace:

Before-Component After-Component Cost

None

Properties:

  • Fuel Type:
  • Max Supply Temp: degrees F
  • Rated AFUE: Btu/Btu

Lifetime:

  • Years
 

Gas, 98% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.98 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit1700 - 33002600
$/kBtuh Input2.7 - 53.9

Install Furnace:

Before-Component After-Component Cost

None

Properties:

  • Fuel Type:
  • Max Supply Temp: degrees F
  • Rated AFUE: Btu/Btu

Lifetime:

  • Years
 

Oil, 78% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit820 - 17001300
$/kBtuh Input1.9 - 3.52.7

Install Furnace:

Before-Component After-Component Cost

None

Properties:

  • Fuel Type:
  • Max Supply Temp: degrees F
  • Rated AFUE: Btu/Btu

Lifetime:

  • Years
 

Oil, 80% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input1.9 - 3.52.7
$/unit1000 - 20001600

Install Furnace:

Before-Component After-Component Cost

None

Properties:

  • Fuel Type:
  • Max Supply Temp: degrees F
  • Rated AFUE: Btu/Btu

Lifetime:

  • Years
 

Oil, 85% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.85 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit1500 - 29002200
$/kBtuh Input1.9 - 3.52.7

Install Furnace:

Before-Component After-Component Cost

None

Properties:

  • Fuel Type:
  • Max Supply Temp: degrees F
  • Rated AFUE: Btu/Btu

Lifetime:

  • Years
 

Oil, 90% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.9 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit1900 - 37002900
$/kBtuh Input2.7 - 53.9

Install Furnace:

Before-Component After-Component Cost

None

Properties:

  • Fuel Type:
  • Max Supply Temp: degrees F
  • Rated AFUE: Btu/Btu

Lifetime:

  • Years
 

Oil, 94% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.94 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit2500 - 48003700
$/kBtuh Input2.7 - 53.9

Install Furnace:

Before-Component After-Component Cost

None

Properties:

  • Fuel Type:
  • Max Supply Temp: degrees F
  • Rated AFUE: Btu/Btu

Lifetime:

  • Years
 

Oil, 95% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.95 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Exceeds Energy Star 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit2600 - 50003900
$/kBtuh Input2.7 - 53.9

Install Furnace:

Before-Component After-Component Cost

None

Properties:

  • Fuel Type:
  • Max Supply Temp: degrees F
  • Rated AFUE: Btu/Btu

Lifetime:

  • Years
 

Oil, 96% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.96 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit2400 - 53004000
$/kBtuh Input2.3 - 53.9

Install Furnace:

Before-Component After-Component Cost

None

Properties:

  • Fuel Type:
  • Max Supply Temp: degrees F
  • Rated AFUE: Btu/Btu

Lifetime:

  • Years
 

Propane, 78% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input1.9 - 3.52.7
$/unit820 - 17001300

Install Furnace:

Before-Component After-Component Cost

None

Properties:

  • Fuel Type:
  • Max Supply Temp: degrees F
  • Rated AFUE: Btu/Btu

Lifetime:

  • Years
 

Propane, 80% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit1000 - 20001600
$/kBtuh Input1.9 - 3.52.7

Install Furnace:

Before-Component After-Component Cost

None

Properties:

  • Fuel Type:
  • Max Supply Temp: degrees F
  • Rated AFUE: Btu/Btu

Lifetime:

  • Years
 

Propane, 82% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.82 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit1200 - 24001800
$/kBtuh Input1.9 - 3.52.7

Install Furnace:

Before-Component After-Component Cost

None

Properties:

  • Fuel Type:
  • Max Supply Temp: degrees F
  • Rated AFUE: Btu/Btu

Lifetime:

  • Years
 

Propane, 90% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.9 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit1900 - 37002900

Install Furnace:

Before-Component After-Component Cost

None

Properties:

  • Fuel Type:
  • Max Supply Temp: degrees F
  • Rated AFUE: Btu/Btu

Lifetime:

  • Years
 

Propane, 92% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.92 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit2100 - 42003200

Install Furnace:

Before-Component After-Component Cost

None

Properties:

  • Fuel Type:
  • Max Supply Temp: degrees F
  • Rated AFUE: Btu/Btu

Lifetime:

  • Years
 

Propane, 94% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.94 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit2400 - 46003500

Install Furnace:

Before-Component After-Component Cost

None

Properties:

  • Fuel Type:
  • Max Supply Temp: degrees F
  • Rated AFUE: Btu/Btu

Lifetime:

  • Years
 

Propane, 95% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.95 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit540 - 1200900

Install Furnace:

Before-Component After-Component Cost

None

Properties:

  • Fuel Type:
  • Max Supply Temp: degrees F
  • Rated AFUE: Btu/Btu

Lifetime:

  • Years
 

Propane, 96% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.96 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit2600 - 50003900
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Oil, 72% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.72 Btu/Btu

Lifetime:

  • 15 Years
 

Electric, 100% AFUE

Properties:

  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 1.0 Btu/Btu

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit1000 - 21001600
$/kBtuh Input35 - 6550

Replace Furnace:

Before-Component After-Component Cost

Oil, 72% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.72 Btu/Btu

Lifetime:

  • 15 Years
 

Gas, 78% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit1200 - 24001800
$/kBtuh Input1.9 - 3.52.7

Replace Furnace:

Before-Component After-Component Cost

Oil, 72% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.72 Btu/Btu

Lifetime:

  • 15 Years
 

Gas, 80% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Meets Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit1200 - 24001900
$/kBtuh Input1.9 - 3.52.7

Replace Furnace:

Before-Component After-Component Cost

Oil, 72% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.72 Btu/Btu

Lifetime:

  • 15 Years
 

Gas, 90% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.9 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit1300 - 27002100

Replace Furnace:

Before-Component After-Component Cost

Oil, 72% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.72 Btu/Btu

Lifetime:

  • 15 Years
 

Gas, 92.5% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.925 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit1500 - 30002300

Replace Furnace:

Before-Component After-Component Cost

Oil, 72% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.72 Btu/Btu

Lifetime:

  • 15 Years
 

Gas, 95% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.95 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit1700 - 33002500

Replace Furnace:

Before-Component After-Component Cost

Oil, 72% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.72 Btu/Btu

Lifetime:

  • 15 Years
 

Gas, 96% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.96 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit1700 - 34002600
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Oil, 72% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.72 Btu/Btu

Lifetime:

  • 15 Years
 

Gas, 98% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.98 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit1900 - 36002800
$/kBtuh Input2.7 - 53.9

Remove Furnace:

Before-Component After-Component Cost

Oil, 72% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.72 Btu/Btu

Lifetime:

  • 15 Years
 

None

Properties:

  • Fuel Type:
  • Max Supply Temp: degrees F
  • Rated AFUE: Btu/Btu

Lifetime:

  • Years
 

Measure Cost

UnitsRangeAverage
$/unit140 - 300230

Replace Furnace:

Before-Component After-Component Cost

Oil, 72% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.72 Btu/Btu

Lifetime:

  • 15 Years
 

Oil, 78% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit970 - 20001500
$/kBtuh Input1.9 - 3.52.7

Replace Furnace:

Before-Component After-Component Cost

Oil, 72% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.72 Btu/Btu

Lifetime:

  • 15 Years
 

Oil, 80% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit1100 - 23001800
$/kBtuh Input1.9 - 3.52.7

Replace Furnace:

Before-Component After-Component Cost

Oil, 72% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.72 Btu/Btu

Lifetime:

  • 15 Years
 

Oil, 85% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.85 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit1600 - 32002500
$/kBtuh Input1.9 - 3.52.7

Replace Furnace:

Before-Component After-Component Cost

Oil, 72% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.72 Btu/Btu

Lifetime:

  • 15 Years
 

Oil, 90% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.9 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit2100 - 40003100
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Oil, 72% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.72 Btu/Btu

Lifetime:

  • 15 Years
 

Oil, 94% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.94 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit2600 - 51003900

Replace Furnace:

Before-Component After-Component Cost

Oil, 72% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.72 Btu/Btu

Lifetime:

  • 15 Years
 

Oil, 95% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.95 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Exceeds Energy Star 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit2800 - 53004100

Replace Furnace:

Before-Component After-Component Cost

Oil, 72% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.72 Btu/Btu

Lifetime:

  • 15 Years
 

Oil, 96% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.96 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit2600 - 56004300
$/kBtuh Input2.3 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Oil, 72% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.72 Btu/Btu

Lifetime:

  • 15 Years
 

Propane, 78% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit970 - 20001500
$/kBtuh Input1.9 - 3.52.7

Replace Furnace:

Before-Component After-Component Cost

Oil, 72% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.72 Btu/Btu

Lifetime:

  • 15 Years
 

Propane, 80% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit1100 - 23001800
$/kBtuh Input1.9 - 3.52.7

Replace Furnace:

Before-Component After-Component Cost

Oil, 72% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.72 Btu/Btu

Lifetime:

  • 15 Years
 

Propane, 82% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.82 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input1.9 - 3.52.7
$/unit1300 - 27002100

Replace Furnace:

Before-Component After-Component Cost

Oil, 72% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.72 Btu/Btu

Lifetime:

  • 15 Years
 

Propane, 90% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.9 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit2100 - 40003100
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Oil, 72% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.72 Btu/Btu

Lifetime:

  • 15 Years
 

Propane, 92% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.92 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit2300 - 45003400

Replace Furnace:

Before-Component After-Component Cost

Oil, 72% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.72 Btu/Btu

Lifetime:

  • 15 Years
 

Propane, 94% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.94 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit2500 - 49003800
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Oil, 72% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.72 Btu/Btu

Lifetime:

  • 15 Years
 

Propane, 95% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.95 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 72% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.72 Btu/Btu

Lifetime:

  • 15 Years
 

Propane, 96% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.96 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit2800 - 53004100

Replace Furnace:

Before-Component After-Component Cost

Oil, 76% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.76 Btu/Btu

Lifetime:

  • 15 Years
 

Electric, 100% AFUE

Properties:

  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 1.0 Btu/Btu

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input35 - 6550
$/unit1000 - 21001600

Replace Furnace:

Before-Component After-Component Cost

Oil, 76% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.76 Btu/Btu

Lifetime:

  • 15 Years
 

Gas, 78% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input1.9 - 3.52.7
$/unit1200 - 24001800

Replace Furnace:

Before-Component After-Component Cost

Oil, 76% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.76 Btu/Btu

Lifetime:

  • 15 Years
 

Gas, 80% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Meets Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input1.9 - 3.52.7
$/unit1200 - 24001900

Replace Furnace:

Before-Component After-Component Cost

Oil, 76% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.76 Btu/Btu

Lifetime:

  • 15 Years
 

Gas, 90% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.9 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit1300 - 27002100
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Oil, 76% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.76 Btu/Btu

Lifetime:

  • 15 Years
 

Gas, 92.5% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.925 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit1500 - 30002300
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Oil, 76% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.76 Btu/Btu

Lifetime:

  • 15 Years
 

Gas, 95% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.95 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit1700 - 33002500

Replace Furnace:

Before-Component After-Component Cost

Oil, 76% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.76 Btu/Btu

Lifetime:

  • 15 Years
 

Gas, 96% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.96 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit1700 - 34002600

Replace Furnace:

Before-Component After-Component Cost

Oil, 76% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.76 Btu/Btu

Lifetime:

  • 15 Years
 

Gas, 98% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.98 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit1900 - 36002800
$/kBtuh Input2.7 - 53.9

Remove Furnace:

Before-Component After-Component Cost

Oil, 76% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.76 Btu/Btu

Lifetime:

  • 15 Years
 

None

Properties:

  • Fuel Type:
  • Max Supply Temp: degrees F
  • Rated AFUE: Btu/Btu

Lifetime:

  • Years
 

Measure Cost

UnitsRangeAverage
$/unit140 - 300230

Replace Furnace:

Before-Component After-Component Cost

Oil, 76% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.76 Btu/Btu

Lifetime:

  • 15 Years
 

Oil, 78% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input1.9 - 3.52.7
$/unit970 - 20001500

Replace Furnace:

Before-Component After-Component Cost

Oil, 76% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.76 Btu/Btu

Lifetime:

  • 15 Years
 

Oil, 80% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input1.9 - 3.52.7
$/unit1100 - 23001800

Replace Furnace:

Before-Component After-Component Cost

Oil, 76% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.76 Btu/Btu

Lifetime:

  • 15 Years
 

Oil, 85% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.85 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit1600 - 32002500
$/kBtuh Input1.9 - 3.52.7

Replace Furnace:

Before-Component After-Component Cost

Oil, 76% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.76 Btu/Btu

Lifetime:

  • 15 Years
 

Oil, 90% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.9 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit2100 - 40003100
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Oil, 76% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.76 Btu/Btu

Lifetime:

  • 15 Years
 

Oil, 94% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.94 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit2600 - 51003900

Replace Furnace:

Before-Component After-Component Cost

Oil, 76% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.76 Btu/Btu

Lifetime:

  • 15 Years
 

Oil, 95% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.95 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Exceeds Energy Star 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit2800 - 53004100
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Oil, 76% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.76 Btu/Btu

Lifetime:

  • 15 Years
 

Oil, 96% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.96 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit2600 - 56004300
$/kBtuh Input2.3 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Oil, 76% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.76 Btu/Btu

Lifetime:

  • 15 Years
 

Propane, 78% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input1.9 - 3.52.7
$/unit970 - 20001500

Replace Furnace:

Before-Component After-Component Cost

Oil, 76% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.76 Btu/Btu

Lifetime:

  • 15 Years
 

Propane, 80% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit1100 - 23001800
$/kBtuh Input1.9 - 3.52.7

Replace Furnace:

Before-Component After-Component Cost

Oil, 76% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.76 Btu/Btu

Lifetime:

  • 15 Years
 

Propane, 82% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.82 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input1.9 - 3.52.7
$/unit1300 - 27002100

Replace Furnace:

Before-Component After-Component Cost

Oil, 76% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.76 Btu/Btu

Lifetime:

  • 15 Years
 

Propane, 90% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.9 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit2100 - 40003100
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Oil, 76% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.76 Btu/Btu

Lifetime:

  • 15 Years
 

Propane, 92% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.92 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit2300 - 45003400

Replace Furnace:

Before-Component After-Component Cost

Oil, 76% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.76 Btu/Btu

Lifetime:

  • 15 Years
 

Propane, 94% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.94 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit2500 - 49003800

Replace Furnace:

Before-Component After-Component Cost

Oil, 76% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.76 Btu/Btu

Lifetime:

  • 15 Years
 

Propane, 95% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.95 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 76% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.76 Btu/Btu

Lifetime:

  • 15 Years
 

Propane, 96% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.96 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit2800 - 53004100

Replace Furnace:

Before-Component After-Component Cost

Oil, 78% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 15 Years
 

Electric, 100% AFUE

Properties:

  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 1.0 Btu/Btu

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input35 - 6550
$/unit1000 - 21001600

Replace Furnace:

Before-Component After-Component Cost

Oil, 78% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 15 Years
 

Gas, 78% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit1200 - 24001800
$/kBtuh Input1.9 - 3.52.7

Replace Furnace:

Before-Component After-Component Cost

Oil, 78% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 15 Years
 

Gas, 80% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Meets Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit1200 - 24001900
$/kBtuh Input1.9 - 3.52.7

Replace Furnace:

Before-Component After-Component Cost

Oil, 78% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 15 Years
 

Gas, 90% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.9 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit1300 - 27002100

Replace Furnace:

Before-Component After-Component Cost

Oil, 78% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 15 Years
 

Gas, 92.5% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.925 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit1500 - 30002300
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Oil, 78% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 15 Years
 

Gas, 95% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.95 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit1700 - 33002500

Replace Furnace:

Before-Component After-Component Cost

Oil, 78% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 15 Years
 

Gas, 96% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.96 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit1700 - 34002600

Replace Furnace:

Before-Component After-Component Cost

Oil, 78% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 15 Years
 

Gas, 98% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.98 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit1900 - 36002800

Remove Furnace:

Before-Component After-Component Cost

Oil, 78% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 15 Years
 

None

Properties:

  • Fuel Type:
  • Max Supply Temp: degrees F
  • Rated AFUE: Btu/Btu

Lifetime:

  • Years
 

Measure Cost

UnitsRangeAverage
$/unit140 - 300230

Replace Furnace:

Before-Component After-Component Cost

Oil, 78% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 15 Years
 

Oil, 78% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input1.9 - 3.52.7
$/unit970 - 20001500

Replace Furnace:

Before-Component After-Component Cost

Oil, 78% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 15 Years
 

Oil, 80% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit1100 - 23001800
$/kBtuh Input1.9 - 3.52.7

Replace Furnace:

Before-Component After-Component Cost

Oil, 78% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 15 Years
 

Oil, 85% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.85 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input1.9 - 3.52.7
$/unit1600 - 32002500

Replace Furnace:

Before-Component After-Component Cost

Oil, 78% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 15 Years
 

Oil, 90% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.9 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit2100 - 40003100

Replace Furnace:

Before-Component After-Component Cost

Oil, 78% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 15 Years
 

Oil, 94% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.94 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit2600 - 51003900
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Oil, 78% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 15 Years
 

Oil, 95% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.95 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Exceeds Energy Star 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit2800 - 53004100
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Oil, 78% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 15 Years
 

Oil, 96% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.96 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.3 - 53.9
$/unit2600 - 56004300

Replace Furnace:

Before-Component After-Component Cost

Oil, 78% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 15 Years
 

Propane, 78% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit970 - 20001500
$/kBtuh Input1.9 - 3.52.7

Replace Furnace:

Before-Component After-Component Cost

Oil, 78% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 15 Years
 

Propane, 80% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input1.9 - 3.52.7
$/unit1100 - 23001800

Replace Furnace:

Before-Component After-Component Cost

Oil, 78% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 15 Years
 

Propane, 82% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.82 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit1300 - 27002100
$/kBtuh Input1.9 - 3.52.7

Replace Furnace:

Before-Component After-Component Cost

Oil, 78% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 15 Years
 

Propane, 90% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.9 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit2100 - 40003100

Replace Furnace:

Before-Component After-Component Cost

Oil, 78% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 15 Years
 

Propane, 92% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.92 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit2300 - 45003400
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Oil, 78% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 15 Years
 

Propane, 94% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.94 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit2500 - 49003800

Replace Furnace:

Before-Component After-Component Cost

Oil, 78% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 15 Years
 

Propane, 95% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.95 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 78% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 15 Years
 

Propane, 96% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.96 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit2800 - 53004100
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Oil, 80% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Electric, 100% AFUE

Properties:

  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 1.0 Btu/Btu

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit1000 - 21001600
$/kBtuh Input35 - 6550

Replace Furnace:

Before-Component After-Component Cost

Oil, 80% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Gas, 78% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input1.9 - 3.52.7
$/unit1200 - 24001800

Replace Furnace:

Before-Component After-Component Cost

Oil, 80% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Gas, 80% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Meets Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input1.9 - 3.52.7
$/unit1200 - 24001900

Replace Furnace:

Before-Component After-Component Cost

Oil, 80% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Gas, 90% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.9 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit1300 - 27002100

Replace Furnace:

Before-Component After-Component Cost

Oil, 80% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Gas, 92.5% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.925 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit1500 - 30002300
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Oil, 80% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Gas, 95% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.95 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit1700 - 33002500

Replace Furnace:

Before-Component After-Component Cost

Oil, 80% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Gas, 96% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.96 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit1700 - 34002600

Replace Furnace:

Before-Component After-Component Cost

Oil, 80% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Gas, 98% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.98 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit1900 - 36002800

Remove Furnace:

Before-Component After-Component Cost

Oil, 80% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

None

Properties:

  • Fuel Type:
  • Max Supply Temp: degrees F
  • Rated AFUE: Btu/Btu

Lifetime:

  • Years
 

Measure Cost

UnitsRangeAverage
$/unit140 - 300230

Replace Furnace:

Before-Component After-Component Cost

Oil, 80% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Oil, 80% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit1100 - 23001800
$/kBtuh Input1.9 - 3.52.7

Replace Furnace:

Before-Component After-Component Cost

Oil, 80% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Oil, 85% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.85 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit1600 - 32002500
$/kBtuh Input1.9 - 3.52.7

Replace Furnace:

Before-Component After-Component Cost

Oil, 80% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Oil, 90% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.9 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit2100 - 40003100
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Oil, 80% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Oil, 94% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.94 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit2600 - 51003900
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Oil, 80% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Oil, 95% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.95 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Exceeds Energy Star 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit2800 - 53004100
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Oil, 80% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Oil, 96% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.96 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.3 - 53.9
$/unit2600 - 56004300

Replace Furnace:

Before-Component After-Component Cost

Oil, 80% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Propane, 78% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input1.9 - 3.52.7
$/unit970 - 20001500

Replace Furnace:

Before-Component After-Component Cost

Oil, 80% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Propane, 80% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit1100 - 23001800
$/kBtuh Input1.9 - 3.52.7

Replace Furnace:

Before-Component After-Component Cost

Oil, 80% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Propane, 82% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.82 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input1.9 - 3.52.7
$/unit1300 - 27002100

Replace Furnace:

Before-Component After-Component Cost

Oil, 80% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Propane, 90% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.9 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit2100 - 40003100
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Oil, 80% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Propane, 92% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.92 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit2300 - 45003400
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Oil, 80% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Propane, 94% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.94 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit2500 - 49003800
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Oil, 80% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Propane, 95% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.95 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit680 - 15001100

Replace Furnace:

Before-Component After-Component Cost

Oil, 80% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Propane, 96% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.96 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit2800 - 53004100

Replace Furnace:

Before-Component After-Component Cost

Oil, 85% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.85 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 15 Years
 

Electric, 100% AFUE

Properties:

  • Fuel Type: electric
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 1.0 Btu/Btu

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input35 - 6550
$/unit1000 - 21001600

Replace Furnace:

Before-Component After-Component Cost

Oil, 85% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.85 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 15 Years
 

Gas, 78% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input1.9 - 3.52.7
$/unit1200 - 24001800

Replace Furnace:

Before-Component After-Component Cost

Oil, 85% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.85 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 15 Years
 

Gas, 80% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Meets Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input1.9 - 3.52.7
$/unit1200 - 24001900

Replace Furnace:

Before-Component After-Component Cost

Oil, 85% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.85 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 15 Years
 

Gas, 90% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.9 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit1300 - 27002100
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Oil, 85% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.85 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 15 Years
 

Gas, 92.5% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.925 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit1500 - 30002300
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Oil, 85% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.85 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 15 Years
 

Gas, 95% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.95 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit1700 - 33002500

Replace Furnace:

Before-Component After-Component Cost

Oil, 85% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.85 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 15 Years
 

Gas, 96% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.96 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit1700 - 34002600

Replace Furnace:

Before-Component After-Component Cost

Oil, 85% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.85 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 15 Years
 

Gas, 98% AFUE

Properties:

  • Fuel Type: gas
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.98 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992
  • Exceeds Energy Star 2006

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit1900 - 36002800
$/kBtuh Input2.7 - 53.9

Remove Furnace:

Before-Component After-Component Cost

Oil, 85% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.85 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 15 Years
 

None

Properties:

  • Fuel Type:
  • Max Supply Temp: degrees F
  • Rated AFUE: Btu/Btu

Lifetime:

  • Years
 

Measure Cost

UnitsRangeAverage
$/unit140 - 300230

Replace Furnace:

Before-Component After-Component Cost

Oil, 85% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.85 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 15 Years
 

Oil, 85% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.85 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit1600 - 32002500
$/kBtuh Input1.9 - 3.52.7

Replace Furnace:

Before-Component After-Component Cost

Oil, 85% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.85 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 15 Years
 

Oil, 90% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.9 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit2100 - 40003100

Replace Furnace:

Before-Component After-Component Cost

Oil, 85% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.85 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 15 Years
 

Oil, 94% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.94 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/kBtuh Input2.7 - 53.9
$/unit2600 - 51003900

Replace Furnace:

Before-Component After-Component Cost

Oil, 85% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.85 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 15 Years
 

Oil, 95% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.95 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Exceeds Energy Star 2006

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit2800 - 53004100
$/kBtuh Input2.7 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Oil, 85% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.85 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 15 Years
 

Oil, 96% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.96 Btu/Btu

Performance Standards:

  • Exceeds Energy Star 2006
  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 15 Years
 

Measure Cost

UnitsRangeAverage
$/unit2600 - 56004300
$/kBtuh Input2.3 - 53.9

Replace Furnace:

Before-Component After-Component Cost

Oil, 85% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.85 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 15 Years
 

Propane, 78% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.78 Btu/Btu

Performance Standards:

  • Meets Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit970 - 20001500
$/kBtuh Input1.9 - 3.52.7

Replace Furnace:

Before-Component After-Component Cost

Oil, 85% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.85 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 15 Years
 

Propane, 80% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.8 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Meets Federal Standard 2015

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit1100 - 23001800
$/kBtuh Input1.9 - 3.52.7

Replace Furnace:

Before-Component After-Component Cost

Oil, 85% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.85 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 15 Years
 

Propane, 82% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.82 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 2015
  • Exceeds Federal Standard 1992

Lifetime:

  • 20 Years
 

Measure Cost

UnitsRangeAverage
$/unit1300 - 27002100
$/kBtuh Input1.9 - 3.52.7

Replace Furnace:

Before-Component After-Component Cost

Oil, 85% AFUE

Properties:

  • Fuel Type: oil
  • Max Supply Temp: 120.0 degrees F
  • Rated AFUE: 0.85 Btu/Btu

Performance Standards:

  • Exceeds Federal Standard 1992
  • Exceeds Federal Standard 2015
  • Meets Energy Star 2006

Lifetime:

  • 15 Years
 

Propane, 90% AFUE

Properties:

  • Fuel Type: propane
  • Max Supply Temp: 120.0 degrees F