Retrofit Measures for Furnace
Here you will find the data for Furnace measures available in the National Residential Efficiency Measures Database. Each measure consists of a before-component, an after-component, and the estimated cost to implement the measure.
The measures are listed alphabetically based upon the name of the before-component. Where multiple costs are indicated they must be combined to obtain total measure cost (e.g., fixed ($) and normalized ($/sf) costs).
Cost Drivers
There are many factors that influence the ultimate cost of Furnace measures.
The application of the average measure costs displayed below to any particular home is discouraged.
Examples of the kinds of issues that can influence the cost of Furnace measures include:
- Prevailing local wages
- Drive time
- Local code requirements
- Access
- Condition of existing flue
- Need to bring in combustion air
- Condition of existing electrical system
- Need for additional wiring/switching
- Condition of existing gas line
- Presence of hazardous materials
- Stand alone vs treating both heating/cooling
- Need for controls and/or zoning
- Condition of existing duct system
- Type of equipment
Replace Furnace:
Before-Component |
After-Component |
Cost |
Electric, 100% AFUE
Properties:
- Fuel Type: electric
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 1.0 Btu/Btu
Lifetime:
|
Electric, 100% AFUE
Properties:
- Fuel Type: electric
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 1.0 Btu/Btu
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1000 - 2100 | 1600 |
$/kBtuh Input | 35 - 65 | 50 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Electric, 100% AFUE
Properties:
- Fuel Type: electric
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 1.0 Btu/Btu
Lifetime:
|
Gas, 78% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
$/unit | 1200 - 2400 | 1800 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Electric, 100% AFUE
Properties:
- Fuel Type: electric
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 1.0 Btu/Btu
Lifetime:
|
Gas, 80% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Meets Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1200 - 2400 | 1900 |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Electric, 100% AFUE
Properties:
- Fuel Type: electric
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 1.0 Btu/Btu
Lifetime:
|
Gas, 90% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.9 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1300 - 2700 | 2100 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Electric, 100% AFUE
Properties:
- Fuel Type: electric
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 1.0 Btu/Btu
Lifetime:
|
Gas, 92.5% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.925 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1500 - 3000 | 2300 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Electric, 100% AFUE
Properties:
- Fuel Type: electric
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 1.0 Btu/Btu
Lifetime:
|
Gas, 95% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.95 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1700 - 3300 | 2500 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Electric, 100% AFUE
Properties:
- Fuel Type: electric
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 1.0 Btu/Btu
Lifetime:
|
Gas, 96% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.96 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1700 - 3400 | 2600 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Electric, 100% AFUE
Properties:
- Fuel Type: electric
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 1.0 Btu/Btu
Lifetime:
|
Gas, 98% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.98 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1900 - 3600 | 2800 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Remove Furnace:
Before-Component |
After-Component |
Cost |
Electric, 100% AFUE
Properties:
- Fuel Type: electric
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 1.0 Btu/Btu
Lifetime:
|
None
Properties:
- Fuel Type:
- Max Supply Temp: degrees F
- Rated AFUE: Btu/Btu
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 140 - 300 | 230 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Electric, 100% AFUE
Properties:
- Fuel Type: electric
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 1.0 Btu/Btu
Lifetime:
|
Oil, 78% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
$/unit | 970 - 2000 | 1500 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Electric, 100% AFUE
Properties:
- Fuel Type: electric
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 1.0 Btu/Btu
Lifetime:
|
Oil, 80% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1100 - 2300 | 1800 |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Electric, 100% AFUE
Properties:
- Fuel Type: electric
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 1.0 Btu/Btu
Lifetime:
|
Oil, 85% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.85 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1600 - 3200 | 2500 |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Electric, 100% AFUE
Properties:
- Fuel Type: electric
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 1.0 Btu/Btu
Lifetime:
|
Oil, 90% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.9 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 2100 - 4000 | 3100 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Electric, 100% AFUE
Properties:
- Fuel Type: electric
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 1.0 Btu/Btu
Lifetime:
|
Oil, 94% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.94 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 2600 - 5100 | 3900 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Electric, 100% AFUE
Properties:
- Fuel Type: electric
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 1.0 Btu/Btu
Lifetime:
|
Oil, 95% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.95 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 2800 - 5300 | 4100 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Electric, 100% AFUE
Properties:
- Fuel Type: electric
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 1.0 Btu/Btu
Lifetime:
|
Oil, 96% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.96 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.3 - 5 | 3.9 |
$/unit | 2600 - 5600 | 4300 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Electric, 100% AFUE
Properties:
- Fuel Type: electric
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 1.0 Btu/Btu
Lifetime:
|
Propane, 78% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 970 - 2000 | 1500 |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Electric, 100% AFUE
Properties:
- Fuel Type: electric
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 1.0 Btu/Btu
Lifetime:
|
Propane, 80% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Meets Federal Standard 2015
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1100 - 2300 | 1800 |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Electric, 100% AFUE
Properties:
- Fuel Type: electric
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 1.0 Btu/Btu
Lifetime:
|
Propane, 82% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.82 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
$/unit | 1300 - 2700 | 2100 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Electric, 100% AFUE
Properties:
- Fuel Type: electric
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 1.0 Btu/Btu
Lifetime:
|
Propane, 90% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.9 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 2100 - 4000 | 3100 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Electric, 100% AFUE
Properties:
- Fuel Type: electric
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 1.0 Btu/Btu
Lifetime:
|
Propane, 92% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.92 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 2300 - 4500 | 3400 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Electric, 100% AFUE
Properties:
- Fuel Type: electric
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 1.0 Btu/Btu
Lifetime:
|
Propane, 94% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.94 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 2500 - 4900 | 3800 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Electric, 100% AFUE
Properties:
- Fuel Type: electric
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 1.0 Btu/Btu
Lifetime:
|
Propane, 95% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.95 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 680 - 1500 | 1100 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Electric, 100% AFUE
Properties:
- Fuel Type: electric
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 1.0 Btu/Btu
Lifetime:
|
Propane, 96% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.96 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 2800 - 5300 | 4100 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 60% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.6 Btu/Btu
Lifetime:
|
Electric, 100% AFUE
Properties:
- Fuel Type: electric
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 1.0 Btu/Btu
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 35 - 65 | 50 |
$/unit | 1000 - 2100 | 1600 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 60% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.6 Btu/Btu
Lifetime:
|
Gas, 78% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1200 - 2400 | 1800 |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 60% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.6 Btu/Btu
Lifetime:
|
Gas, 80% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Meets Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1200 - 2400 | 1900 |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 60% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.6 Btu/Btu
Lifetime:
|
Gas, 90% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.9 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1300 - 2700 | 2100 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 60% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.6 Btu/Btu
Lifetime:
|
Gas, 92.5% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.925 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 1500 - 3000 | 2300 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 60% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.6 Btu/Btu
Lifetime:
|
Gas, 95% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.95 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 1700 - 3300 | 2500 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 60% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.6 Btu/Btu
Lifetime:
|
Gas, 96% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.96 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 1700 - 3400 | 2600 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 60% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.6 Btu/Btu
Lifetime:
|
Gas, 98% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.98 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1900 - 3600 | 2800 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Remove Furnace:
Before-Component |
After-Component |
Cost |
Gas, 60% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.6 Btu/Btu
Lifetime:
|
None
Properties:
- Fuel Type:
- Max Supply Temp: degrees F
- Rated AFUE: Btu/Btu
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 140 - 300 | 230 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 60% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.6 Btu/Btu
Lifetime:
|
Oil, 78% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 970 - 2000 | 1500 |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 60% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.6 Btu/Btu
Lifetime:
|
Oil, 80% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1100 - 2300 | 1800 |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 60% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.6 Btu/Btu
Lifetime:
|
Oil, 85% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.85 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1600 - 3200 | 2500 |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 60% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.6 Btu/Btu
Lifetime:
|
Oil, 90% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.9 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 2100 - 4000 | 3100 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 60% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.6 Btu/Btu
Lifetime:
|
Oil, 94% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.94 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 2600 - 5100 | 3900 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 60% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.6 Btu/Btu
Lifetime:
|
Oil, 95% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.95 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 2800 - 5300 | 4100 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 60% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.6 Btu/Btu
Lifetime:
|
Oil, 96% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.96 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.3 - 5 | 3.9 |
$/unit | 2600 - 5600 | 4300 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 60% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.6 Btu/Btu
Lifetime:
|
Propane, 78% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
$/unit | 970 - 2000 | 1500 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 60% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.6 Btu/Btu
Lifetime:
|
Propane, 80% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Meets Federal Standard 2015
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1100 - 2300 | 1800 |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 60% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.6 Btu/Btu
Lifetime:
|
Propane, 82% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.82 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1300 - 2700 | 2100 |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 60% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.6 Btu/Btu
Lifetime:
|
Propane, 90% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.9 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 2100 - 4000 | 3100 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 60% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.6 Btu/Btu
Lifetime:
|
Propane, 92% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.92 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 2300 - 4500 | 3400 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 60% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.6 Btu/Btu
Lifetime:
|
Propane, 94% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.94 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 2500 - 4900 | 3800 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 60% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.6 Btu/Btu
Lifetime:
|
Propane, 95% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.95 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 680 - 1500 | 1100 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 60% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.6 Btu/Btu
Lifetime:
|
Propane, 96% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.96 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 2800 - 5300 | 4100 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 64% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.64 Btu/Btu
Lifetime:
|
Electric, 100% AFUE
Properties:
- Fuel Type: electric
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 1.0 Btu/Btu
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 35 - 65 | 50 |
$/unit | 1000 - 2100 | 1600 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 64% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.64 Btu/Btu
Lifetime:
|
Gas, 78% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
$/unit | 1200 - 2400 | 1800 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 64% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.64 Btu/Btu
Lifetime:
|
Gas, 80% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Meets Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1200 - 2400 | 1900 |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 64% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.64 Btu/Btu
Lifetime:
|
Gas, 90% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.9 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 1300 - 2700 | 2100 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 64% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.64 Btu/Btu
Lifetime:
|
Gas, 92.5% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.925 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 1500 - 3000 | 2300 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 64% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.64 Btu/Btu
Lifetime:
|
Gas, 95% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.95 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 1700 - 3300 | 2500 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 64% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.64 Btu/Btu
Lifetime:
|
Gas, 96% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.96 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 1700 - 3400 | 2600 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 64% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.64 Btu/Btu
Lifetime:
|
Gas, 98% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.98 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 1900 - 3600 | 2800 |
|
Remove Furnace:
Before-Component |
After-Component |
Cost |
Gas, 64% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.64 Btu/Btu
Lifetime:
|
None
Properties:
- Fuel Type:
- Max Supply Temp: degrees F
- Rated AFUE: Btu/Btu
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 140 - 300 | 230 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 64% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.64 Btu/Btu
Lifetime:
|
Oil, 78% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 970 - 2000 | 1500 |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 64% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.64 Btu/Btu
Lifetime:
|
Oil, 80% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1100 - 2300 | 1800 |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 64% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.64 Btu/Btu
Lifetime:
|
Oil, 85% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.85 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1600 - 3200 | 2500 |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 64% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.64 Btu/Btu
Lifetime:
|
Oil, 90% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.9 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 2100 - 4000 | 3100 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 64% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.64 Btu/Btu
Lifetime:
|
Oil, 94% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.94 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 2600 - 5100 | 3900 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 64% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.64 Btu/Btu
Lifetime:
|
Oil, 95% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.95 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 2800 - 5300 | 4100 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 64% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.64 Btu/Btu
Lifetime:
|
Oil, 96% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.96 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.3 - 5 | 3.9 |
$/unit | 2600 - 5600 | 4300 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 64% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.64 Btu/Btu
Lifetime:
|
Propane, 78% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
$/unit | 970 - 2000 | 1500 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 64% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.64 Btu/Btu
Lifetime:
|
Propane, 80% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Meets Federal Standard 2015
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
$/unit | 1100 - 2300 | 1800 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 64% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.64 Btu/Btu
Lifetime:
|
Propane, 82% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.82 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1300 - 2700 | 2100 |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 64% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.64 Btu/Btu
Lifetime:
|
Propane, 90% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.9 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 2100 - 4000 | 3100 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 64% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.64 Btu/Btu
Lifetime:
|
Propane, 92% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.92 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 2300 - 4500 | 3400 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 64% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.64 Btu/Btu
Lifetime:
|
Propane, 94% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.94 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 2500 - 4900 | 3800 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 64% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.64 Btu/Btu
Lifetime:
|
Propane, 95% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.95 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 680 - 1500 | 1100 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 64% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.64 Btu/Btu
Lifetime:
|
Propane, 96% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.96 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 2800 - 5300 | 4100 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 68% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.68 Btu/Btu
Lifetime:
|
Electric, 100% AFUE
Properties:
- Fuel Type: electric
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 1.0 Btu/Btu
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 35 - 65 | 50 |
$/unit | 1000 - 2100 | 1600 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 68% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.68 Btu/Btu
Lifetime:
|
Gas, 78% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1200 - 2400 | 1800 |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 68% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.68 Btu/Btu
Lifetime:
|
Gas, 80% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Meets Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
$/unit | 1200 - 2400 | 1900 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 68% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.68 Btu/Btu
Lifetime:
|
Gas, 90% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.9 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1300 - 2700 | 2100 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 68% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.68 Btu/Btu
Lifetime:
|
Gas, 92.5% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.925 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 1500 - 3000 | 2300 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 68% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.68 Btu/Btu
Lifetime:
|
Gas, 95% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.95 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1700 - 3300 | 2500 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 68% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.68 Btu/Btu
Lifetime:
|
Gas, 96% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.96 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1700 - 3400 | 2600 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 68% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.68 Btu/Btu
Lifetime:
|
Gas, 98% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.98 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1900 - 3600 | 2800 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Remove Furnace:
Before-Component |
After-Component |
Cost |
Gas, 68% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.68 Btu/Btu
Lifetime:
|
None
Properties:
- Fuel Type:
- Max Supply Temp: degrees F
- Rated AFUE: Btu/Btu
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 140 - 300 | 230 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 68% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.68 Btu/Btu
Lifetime:
|
Oil, 78% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 970 - 2000 | 1500 |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 68% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.68 Btu/Btu
Lifetime:
|
Oil, 80% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
$/unit | 1100 - 2300 | 1800 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 68% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.68 Btu/Btu
Lifetime:
|
Oil, 85% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.85 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
$/unit | 1600 - 3200 | 2500 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 68% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.68 Btu/Btu
Lifetime:
|
Oil, 90% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.9 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 2100 - 4000 | 3100 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 68% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.68 Btu/Btu
Lifetime:
|
Oil, 94% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.94 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 2600 - 5100 | 3900 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 68% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.68 Btu/Btu
Lifetime:
|
Oil, 95% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.95 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 2800 - 5300 | 4100 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 68% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.68 Btu/Btu
Lifetime:
|
Oil, 96% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.96 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 2600 - 5600 | 4300 |
$/kBtuh Input | 2.3 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 68% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.68 Btu/Btu
Lifetime:
|
Propane, 78% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
$/unit | 970 - 2000 | 1500 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 68% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.68 Btu/Btu
Lifetime:
|
Propane, 80% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Meets Federal Standard 2015
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1100 - 2300 | 1800 |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 68% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.68 Btu/Btu
Lifetime:
|
Propane, 82% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.82 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1300 - 2700 | 2100 |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 68% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.68 Btu/Btu
Lifetime:
|
Propane, 90% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.9 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 2100 - 4000 | 3100 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 68% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.68 Btu/Btu
Lifetime:
|
Propane, 92% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.92 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 2300 - 4500 | 3400 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 68% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.68 Btu/Btu
Lifetime:
|
Propane, 94% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.94 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 2500 - 4900 | 3800 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 68% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.68 Btu/Btu
Lifetime:
|
Propane, 95% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.95 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 680 - 1500 | 1100 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 68% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.68 Btu/Btu
Lifetime:
|
Propane, 96% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.96 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 2800 - 5300 | 4100 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 72% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.72 Btu/Btu
Lifetime:
|
Electric, 100% AFUE
Properties:
- Fuel Type: electric
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 1.0 Btu/Btu
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 35 - 65 | 50 |
$/unit | 1000 - 2100 | 1600 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 72% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.72 Btu/Btu
Lifetime:
|
Gas, 78% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
$/unit | 1200 - 2400 | 1800 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 72% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.72 Btu/Btu
Lifetime:
|
Gas, 80% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Meets Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1200 - 2400 | 1900 |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 72% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.72 Btu/Btu
Lifetime:
|
Gas, 90% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.9 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1300 - 2700 | 2100 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 72% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.72 Btu/Btu
Lifetime:
|
Gas, 92.5% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.925 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1500 - 3000 | 2300 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 72% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.72 Btu/Btu
Lifetime:
|
Gas, 95% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.95 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 1700 - 3300 | 2500 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 72% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.72 Btu/Btu
Lifetime:
|
Gas, 96% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.96 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1700 - 3400 | 2600 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 72% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.72 Btu/Btu
Lifetime:
|
Gas, 98% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.98 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1900 - 3600 | 2800 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Remove Furnace:
Before-Component |
After-Component |
Cost |
Gas, 72% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.72 Btu/Btu
Lifetime:
|
None
Properties:
- Fuel Type:
- Max Supply Temp: degrees F
- Rated AFUE: Btu/Btu
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 140 - 300 | 230 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 72% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.72 Btu/Btu
Lifetime:
|
Oil, 78% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
$/unit | 970 - 2000 | 1500 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 72% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.72 Btu/Btu
Lifetime:
|
Oil, 80% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1100 - 2300 | 1800 |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 72% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.72 Btu/Btu
Lifetime:
|
Oil, 85% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.85 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
$/unit | 1600 - 3200 | 2500 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 72% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.72 Btu/Btu
Lifetime:
|
Oil, 90% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.9 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 2100 - 4000 | 3100 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 72% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.72 Btu/Btu
Lifetime:
|
Oil, 94% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.94 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 2600 - 5100 | 3900 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 72% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.72 Btu/Btu
Lifetime:
|
Oil, 95% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.95 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 2800 - 5300 | 4100 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 72% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.72 Btu/Btu
Lifetime:
|
Oil, 96% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.96 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 2600 - 5600 | 4300 |
$/kBtuh Input | 2.3 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 72% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.72 Btu/Btu
Lifetime:
|
Propane, 78% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 970 - 2000 | 1500 |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 72% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.72 Btu/Btu
Lifetime:
|
Propane, 80% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Meets Federal Standard 2015
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
$/unit | 1100 - 2300 | 1800 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 72% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.72 Btu/Btu
Lifetime:
|
Propane, 82% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.82 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
$/unit | 1300 - 2700 | 2100 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 72% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.72 Btu/Btu
Lifetime:
|
Propane, 90% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.9 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 2100 - 4000 | 3100 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 72% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.72 Btu/Btu
Lifetime:
|
Propane, 92% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.92 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 2300 - 4500 | 3400 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 72% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.72 Btu/Btu
Lifetime:
|
Propane, 94% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.94 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 2500 - 4900 | 3800 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 72% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.72 Btu/Btu
Lifetime:
|
Propane, 95% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.95 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 680 - 1500 | 1100 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 72% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.72 Btu/Btu
Lifetime:
|
Propane, 96% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.96 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 2800 - 5300 | 4100 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 76% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.76 Btu/Btu
Lifetime:
|
Electric, 100% AFUE
Properties:
- Fuel Type: electric
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 1.0 Btu/Btu
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 35 - 65 | 50 |
$/unit | 1000 - 2100 | 1600 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 76% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.76 Btu/Btu
Lifetime:
|
Gas, 78% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
$/unit | 1200 - 2400 | 1800 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 76% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.76 Btu/Btu
Lifetime:
|
Gas, 80% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Meets Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1200 - 2400 | 1900 |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 76% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.76 Btu/Btu
Lifetime:
|
Gas, 90% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.9 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1300 - 2700 | 2100 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 76% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.76 Btu/Btu
Lifetime:
|
Gas, 92.5% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.925 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1500 - 3000 | 2300 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 76% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.76 Btu/Btu
Lifetime:
|
Gas, 95% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.95 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 1700 - 3300 | 2500 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 76% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.76 Btu/Btu
Lifetime:
|
Gas, 96% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.96 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1700 - 3400 | 2600 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 76% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.76 Btu/Btu
Lifetime:
|
Gas, 98% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.98 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 1900 - 3600 | 2800 |
|
Remove Furnace:
Before-Component |
After-Component |
Cost |
Gas, 76% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.76 Btu/Btu
Lifetime:
|
None
Properties:
- Fuel Type:
- Max Supply Temp: degrees F
- Rated AFUE: Btu/Btu
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 140 - 300 | 230 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 76% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.76 Btu/Btu
Lifetime:
|
Oil, 78% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 970 - 2000 | 1500 |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 76% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.76 Btu/Btu
Lifetime:
|
Oil, 80% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1100 - 2300 | 1800 |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 76% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.76 Btu/Btu
Lifetime:
|
Oil, 85% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.85 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1600 - 3200 | 2500 |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 76% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.76 Btu/Btu
Lifetime:
|
Oil, 90% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.9 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 2100 - 4000 | 3100 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 76% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.76 Btu/Btu
Lifetime:
|
Oil, 94% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.94 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 2600 - 5100 | 3900 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 76% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.76 Btu/Btu
Lifetime:
|
Oil, 95% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.95 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 2800 - 5300 | 4100 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 76% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.76 Btu/Btu
Lifetime:
|
Oil, 96% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.96 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 2600 - 5600 | 4300 |
$/kBtuh Input | 2.3 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 76% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.76 Btu/Btu
Lifetime:
|
Propane, 78% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 970 - 2000 | 1500 |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 76% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.76 Btu/Btu
Lifetime:
|
Propane, 80% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Meets Federal Standard 2015
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1100 - 2300 | 1800 |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 76% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.76 Btu/Btu
Lifetime:
|
Propane, 82% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.82 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
$/unit | 1300 - 2700 | 2100 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 76% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.76 Btu/Btu
Lifetime:
|
Propane, 90% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.9 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 2100 - 4000 | 3100 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 76% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.76 Btu/Btu
Lifetime:
|
Propane, 92% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.92 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 2300 - 4500 | 3400 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 76% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.76 Btu/Btu
Lifetime:
|
Propane, 94% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.94 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 2500 - 4900 | 3800 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 76% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.76 Btu/Btu
Lifetime:
|
Propane, 95% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.95 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 680 - 1500 | 1100 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 76% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.76 Btu/Btu
Lifetime:
|
Propane, 96% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.96 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 2800 - 5300 | 4100 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 78% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Electric, 100% AFUE
Properties:
- Fuel Type: electric
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 1.0 Btu/Btu
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1000 - 2100 | 1600 |
$/kBtuh Input | 35 - 65 | 50 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 78% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Gas, 78% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1200 - 2400 | 1800 |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 78% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Gas, 80% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Meets Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1200 - 2400 | 1900 |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 78% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Gas, 90% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.9 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1300 - 2700 | 2100 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 78% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Gas, 92.5% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.925 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1500 - 3000 | 2300 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 78% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Gas, 95% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.95 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1700 - 3300 | 2500 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 78% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Gas, 96% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.96 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1700 - 3400 | 2600 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 78% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Gas, 98% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.98 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1900 - 3600 | 2800 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Remove Furnace:
Before-Component |
After-Component |
Cost |
Gas, 78% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
None
Properties:
- Fuel Type:
- Max Supply Temp: degrees F
- Rated AFUE: Btu/Btu
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 140 - 300 | 230 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 78% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Oil, 78% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 970 - 2000 | 1500 |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 78% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Oil, 80% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1100 - 2300 | 1800 |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 78% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Oil, 85% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.85 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
$/unit | 1600 - 3200 | 2500 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 78% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Oil, 90% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.9 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 2100 - 4000 | 3100 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 78% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Oil, 94% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.94 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 2600 - 5100 | 3900 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 78% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Oil, 95% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.95 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 2800 - 5300 | 4100 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 78% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Oil, 96% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.96 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 2600 - 5600 | 4300 |
$/kBtuh Input | 2.3 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 78% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Propane, 78% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 970 - 2000 | 1500 |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 78% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Propane, 80% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Meets Federal Standard 2015
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1100 - 2300 | 1800 |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 78% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Propane, 82% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.82 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
$/unit | 1300 - 2700 | 2100 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 78% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Propane, 90% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.9 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 2100 - 4000 | 3100 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 78% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Propane, 92% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.92 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 2300 - 4500 | 3400 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 78% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Propane, 94% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.94 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 2500 - 4900 | 3800 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 78% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Propane, 95% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.95 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 680 - 1500 | 1100 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 78% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Propane, 96% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.96 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 2800 - 5300 | 4100 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 80% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Meets Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Electric, 100% AFUE
Properties:
- Fuel Type: electric
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 1.0 Btu/Btu
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 35 - 65 | 50 |
$/unit | 1000 - 2100 | 1600 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 80% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Meets Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Gas, 80% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Meets Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1200 - 2400 | 1900 |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 80% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Meets Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Gas, 90% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.9 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 1300 - 2700 | 2100 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 80% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Meets Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Gas, 92.5% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.925 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 1500 - 3000 | 2300 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 80% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Meets Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Gas, 95% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.95 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1700 - 3300 | 2500 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 80% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Meets Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Gas, 96% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.96 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1700 - 3400 | 2600 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 80% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Meets Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Gas, 98% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.98 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1900 - 3600 | 2800 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Remove Furnace:
Before-Component |
After-Component |
Cost |
Gas, 80% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Meets Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
None
Properties:
- Fuel Type:
- Max Supply Temp: degrees F
- Rated AFUE: Btu/Btu
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 140 - 300 | 230 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 80% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Meets Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Oil, 78% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
$/unit | 970 - 2000 | 1500 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 80% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Meets Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Oil, 80% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
$/unit | 1100 - 2300 | 1800 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 80% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Meets Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Oil, 85% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.85 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1600 - 3200 | 2500 |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 80% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Meets Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Oil, 90% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.9 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 2100 - 4000 | 3100 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 80% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Meets Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Oil, 94% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.94 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 2600 - 5100 | 3900 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 80% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Meets Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Oil, 95% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.95 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 2800 - 5300 | 4100 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 80% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Meets Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Oil, 96% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.96 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 2600 - 5600 | 4300 |
$/kBtuh Input | 2.3 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 80% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Meets Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Propane, 78% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 970 - 2000 | 1500 |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 80% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Meets Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Propane, 80% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Meets Federal Standard 2015
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
$/unit | 1100 - 2300 | 1800 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 80% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Meets Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Propane, 82% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.82 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1300 - 2700 | 2100 |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 80% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Meets Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Propane, 90% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.9 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 2100 - 4000 | 3100 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 80% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Meets Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Propane, 92% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.92 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 2300 - 4500 | 3400 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 80% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Meets Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Propane, 94% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.94 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 2500 - 4900 | 3800 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 80% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Meets Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Propane, 95% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.95 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 680 - 1500 | 1100 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 80% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Meets Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Propane, 96% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.96 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 2800 - 5300 | 4100 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 90% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.9 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Electric, 100% AFUE
Properties:
- Fuel Type: electric
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 1.0 Btu/Btu
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1000 - 2100 | 1600 |
$/kBtuh Input | 35 - 65 | 50 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 90% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.9 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Gas, 90% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.9 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1300 - 2700 | 2100 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 90% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.9 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Gas, 92.5% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.925 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1500 - 3000 | 2300 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 90% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.9 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Gas, 95% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.95 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 1700 - 3300 | 2500 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 90% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.9 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Gas, 96% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.96 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 1700 - 3400 | 2600 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 90% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.9 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Gas, 98% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.98 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1900 - 3600 | 2800 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Remove Furnace:
Before-Component |
After-Component |
Cost |
Gas, 90% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.9 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
None
Properties:
- Fuel Type:
- Max Supply Temp: degrees F
- Rated AFUE: Btu/Btu
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 140 - 300 | 230 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 90% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.9 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Oil, 78% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
$/unit | 970 - 2000 | 1500 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 90% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.9 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Oil, 80% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1100 - 2300 | 1800 |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 90% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.9 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Oil, 85% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.85 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1600 - 3200 | 2500 |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 90% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.9 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Oil, 90% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.9 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 2100 - 4000 | 3100 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 90% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.9 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Oil, 94% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.94 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 2600 - 5100 | 3900 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 90% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.9 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Oil, 95% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.95 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 2800 - 5300 | 4100 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 90% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.9 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Oil, 96% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.96 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 2600 - 5600 | 4300 |
$/kBtuh Input | 2.3 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 90% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.9 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Propane, 78% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 970 - 2000 | 1500 |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 90% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.9 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Propane, 80% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Meets Federal Standard 2015
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
$/unit | 1100 - 2300 | 1800 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 90% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.9 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Propane, 82% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.82 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
$/unit | 1300 - 2700 | 2100 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 90% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.9 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Propane, 90% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.9 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 2100 - 4000 | 3100 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 90% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.9 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Propane, 92% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.92 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 2300 - 4500 | 3400 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 90% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.9 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Propane, 94% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.94 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 2500 - 4900 | 3800 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 90% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.9 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Propane, 95% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.95 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 680 - 1500 | 1100 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 90% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.9 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Propane, 96% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.96 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 2800 - 5300 | 4100 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 92.5% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.925 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Electric, 100% AFUE
Properties:
- Fuel Type: electric
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 1.0 Btu/Btu
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 35 - 65 | 50 |
$/unit | 1000 - 2100 | 1600 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 92.5% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.925 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Gas, 92.5% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.925 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 1500 - 3000 | 2300 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 92.5% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.925 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Gas, 95% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.95 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 1700 - 3300 | 2500 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 92.5% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.925 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Gas, 96% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.96 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1700 - 3400 | 2600 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 92.5% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.925 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Gas, 98% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.98 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 1900 - 3600 | 2800 |
|
Remove Furnace:
Before-Component |
After-Component |
Cost |
Gas, 92.5% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.925 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
None
Properties:
- Fuel Type:
- Max Supply Temp: degrees F
- Rated AFUE: Btu/Btu
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 140 - 300 | 230 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 92.5% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.925 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Oil, 78% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 970 - 2000 | 1500 |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 92.5% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.925 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Oil, 80% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1100 - 2300 | 1800 |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 92.5% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.925 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Oil, 85% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.85 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
$/unit | 1600 - 3200 | 2500 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 92.5% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.925 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Oil, 90% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.9 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 2100 - 4000 | 3100 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 92.5% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.925 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Oil, 94% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.94 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 2600 - 5100 | 3900 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 92.5% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.925 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Oil, 95% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.95 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 2800 - 5300 | 4100 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 92.5% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.925 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Oil, 96% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.96 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 2600 - 5600 | 4300 |
$/kBtuh Input | 2.3 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 92.5% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.925 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Propane, 78% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
$/unit | 970 - 2000 | 1500 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 92.5% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.925 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Propane, 80% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Meets Federal Standard 2015
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
$/unit | 1100 - 2300 | 1800 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 92.5% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.925 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Propane, 82% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.82 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
$/unit | 1300 - 2700 | 2100 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 92.5% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.925 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Propane, 90% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.9 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 2100 - 4000 | 3100 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 92.5% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.925 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Propane, 92% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.92 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 2300 - 4500 | 3400 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 92.5% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.925 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Propane, 94% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.94 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 2500 - 4900 | 3800 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 92.5% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.925 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Propane, 95% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.95 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 680 - 1500 | 1100 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 92.5% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.925 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Propane, 96% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.96 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 2800 - 5300 | 4100 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 95% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.95 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Electric, 100% AFUE
Properties:
- Fuel Type: electric
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 1.0 Btu/Btu
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1000 - 2100 | 1600 |
$/kBtuh Input | 35 - 65 | 50 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 95% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.95 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Gas, 95% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.95 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1700 - 3300 | 2500 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 95% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.95 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Gas, 96% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.96 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1700 - 3400 | 2600 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 95% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.95 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Gas, 98% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.98 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 1900 - 3600 | 2800 |
|
Remove Furnace:
Before-Component |
After-Component |
Cost |
Gas, 95% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.95 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
None
Properties:
- Fuel Type:
- Max Supply Temp: degrees F
- Rated AFUE: Btu/Btu
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 140 - 300 | 230 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 95% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.95 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Oil, 78% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 970 - 2000 | 1500 |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 95% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.95 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Oil, 80% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
$/unit | 1100 - 2300 | 1800 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 95% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.95 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Oil, 85% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.85 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
$/unit | 1600 - 3200 | 2500 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 95% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.95 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Oil, 90% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.9 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 2100 - 4000 | 3100 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 95% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.95 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Oil, 94% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.94 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 2600 - 5100 | 3900 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 95% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.95 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Oil, 95% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.95 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 2800 - 5300 | 4100 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 95% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.95 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Oil, 96% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.96 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.3 - 5 | 3.9 |
$/unit | 2600 - 5600 | 4300 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 95% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.95 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Propane, 78% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 970 - 2000 | 1500 |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 95% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.95 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Propane, 80% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Meets Federal Standard 2015
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
$/unit | 1100 - 2300 | 1800 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 95% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.95 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Propane, 82% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.82 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1300 - 2700 | 2100 |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 95% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.95 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Propane, 90% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.9 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 2100 - 4000 | 3100 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 95% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.95 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Propane, 92% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.92 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 2300 - 4500 | 3400 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 95% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.95 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Propane, 94% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.94 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 2500 - 4900 | 3800 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 95% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.95 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Propane, 95% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.95 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 680 - 1500 | 1100 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 95% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.95 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Propane, 96% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.96 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 2800 - 5300 | 4100 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 96% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.96 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Electric, 100% AFUE
Properties:
- Fuel Type: electric
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 1.0 Btu/Btu
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 35 - 65 | 50 |
$/unit | 1000 - 2100 | 1600 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 96% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.96 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Gas, 96% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.96 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1700 - 3400 | 2600 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 96% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.96 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Gas, 98% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.98 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 1900 - 3600 | 2800 |
|
Remove Furnace:
Before-Component |
After-Component |
Cost |
Gas, 96% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.96 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
None
Properties:
- Fuel Type:
- Max Supply Temp: degrees F
- Rated AFUE: Btu/Btu
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 140 - 300 | 230 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 96% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.96 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Oil, 78% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
$/unit | 970 - 2000 | 1500 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 96% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.96 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Oil, 80% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
$/unit | 1100 - 2300 | 1800 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 96% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.96 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Oil, 85% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.85 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1600 - 3200 | 2500 |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 96% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.96 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Oil, 90% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.9 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 2100 - 4000 | 3100 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 96% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.96 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Oil, 94% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.94 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 2600 - 5100 | 3900 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 96% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.96 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Oil, 95% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.95 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 2800 - 5300 | 4100 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 96% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.96 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Oil, 96% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.96 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 2600 - 5600 | 4300 |
$/kBtuh Input | 2.3 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 96% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.96 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Propane, 78% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
$/unit | 970 - 2000 | 1500 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 96% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.96 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Propane, 80% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Meets Federal Standard 2015
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1100 - 2300 | 1800 |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 96% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.96 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Propane, 82% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.82 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
$/unit | 1300 - 2700 | 2100 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 96% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.96 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Propane, 90% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.9 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 2100 - 4000 | 3100 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 96% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.96 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Propane, 92% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.92 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 2300 - 4500 | 3400 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 96% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.96 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Propane, 94% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.94 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 2500 - 4900 | 3800 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 96% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.96 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Propane, 95% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.95 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 680 - 1500 | 1100 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 96% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.96 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Propane, 96% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.96 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 2800 - 5300 | 4100 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 98% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.98 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Electric, 100% AFUE
Properties:
- Fuel Type: electric
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 1.0 Btu/Btu
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1000 - 2100 | 1600 |
$/kBtuh Input | 35 - 65 | 50 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 98% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.98 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Gas, 98% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.98 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 1900 - 3600 | 2800 |
|
Remove Furnace:
Before-Component |
After-Component |
Cost |
Gas, 98% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.98 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
None
Properties:
- Fuel Type:
- Max Supply Temp: degrees F
- Rated AFUE: Btu/Btu
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 140 - 300 | 230 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 98% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.98 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Oil, 78% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 970 - 2000 | 1500 |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 98% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.98 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Oil, 80% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
$/unit | 1100 - 2300 | 1800 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 98% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.98 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Oil, 85% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.85 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1600 - 3200 | 2500 |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 98% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.98 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Oil, 90% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.9 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 2100 - 4000 | 3100 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 98% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.98 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Oil, 94% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.94 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 2600 - 5100 | 3900 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 98% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.98 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Oil, 95% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.95 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 2800 - 5300 | 4100 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 98% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.98 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Oil, 96% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.96 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 2600 - 5600 | 4300 |
$/kBtuh Input | 2.3 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 98% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.98 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Propane, 78% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
$/unit | 970 - 2000 | 1500 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 98% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.98 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Propane, 80% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Meets Federal Standard 2015
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
$/unit | 1100 - 2300 | 1800 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 98% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.98 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Propane, 82% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.82 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
$/unit | 1300 - 2700 | 2100 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 98% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.98 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Propane, 90% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.9 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 2100 - 4000 | 3100 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 98% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.98 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Propane, 92% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.92 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 2300 - 4500 | 3400 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 98% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.98 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Propane, 94% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.94 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 2500 - 4900 | 3800 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 98% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.98 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Propane, 95% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.95 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 680 - 1500 | 1100 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Gas, 98% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.98 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Propane, 96% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.96 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 2800 - 5300 | 4100 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Install Furnace:
Before-Component |
After-Component |
Cost |
None
Properties:
- Fuel Type:
- Max Supply Temp: degrees F
- Rated AFUE: Btu/Btu
Lifetime:
|
Electric, 100% AFUE
Properties:
- Fuel Type: electric
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 1.0 Btu/Btu
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 35 - 65 | 50 |
$/unit | 890 - 1800 | 1400 |
|
Install Furnace:
Before-Component |
After-Component |
Cost |
None
Properties:
- Fuel Type:
- Max Supply Temp: degrees F
- Rated AFUE: Btu/Btu
Lifetime:
|
Gas, 78% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1000 - 2100 | 1600 |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
|
Install Furnace:
Before-Component |
After-Component |
Cost |
None
Properties:
- Fuel Type:
- Max Supply Temp: degrees F
- Rated AFUE: Btu/Btu
Lifetime:
|
Gas, 80% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Meets Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
$/unit | 1100 - 2100 | 1600 |
|
Install Furnace:
Before-Component |
After-Component |
Cost |
None
Properties:
- Fuel Type:
- Max Supply Temp: degrees F
- Rated AFUE: Btu/Btu
Lifetime:
|
Gas, 90% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.9 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 1200 - 2400 | 1800 |
|
Install Furnace:
Before-Component |
After-Component |
Cost |
None
Properties:
- Fuel Type:
- Max Supply Temp: degrees F
- Rated AFUE: Btu/Btu
Lifetime:
|
Gas, 92.5% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.925 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 1400 - 2700 | 2100 |
|
Install Furnace:
Before-Component |
After-Component |
Cost |
None
Properties:
- Fuel Type:
- Max Supply Temp: degrees F
- Rated AFUE: Btu/Btu
Lifetime:
|
Gas, 95% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.95 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1500 - 3000 | 2300 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Install Furnace:
Before-Component |
After-Component |
Cost |
None
Properties:
- Fuel Type:
- Max Supply Temp: degrees F
- Rated AFUE: Btu/Btu
Lifetime:
|
Gas, 96% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.96 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1600 - 3100 | 2400 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Install Furnace:
Before-Component |
After-Component |
Cost |
None
Properties:
- Fuel Type:
- Max Supply Temp: degrees F
- Rated AFUE: Btu/Btu
Lifetime:
|
Gas, 98% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.98 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1700 - 3300 | 2600 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Install Furnace:
Before-Component |
After-Component |
Cost |
None
Properties:
- Fuel Type:
- Max Supply Temp: degrees F
- Rated AFUE: Btu/Btu
Lifetime:
|
Oil, 78% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 820 - 1700 | 1300 |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
|
Install Furnace:
Before-Component |
After-Component |
Cost |
None
Properties:
- Fuel Type:
- Max Supply Temp: degrees F
- Rated AFUE: Btu/Btu
Lifetime:
|
Oil, 80% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
$/unit | 1000 - 2000 | 1600 |
|
Install Furnace:
Before-Component |
After-Component |
Cost |
None
Properties:
- Fuel Type:
- Max Supply Temp: degrees F
- Rated AFUE: Btu/Btu
Lifetime:
|
Oil, 85% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.85 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1500 - 2900 | 2200 |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
|
Install Furnace:
Before-Component |
After-Component |
Cost |
None
Properties:
- Fuel Type:
- Max Supply Temp: degrees F
- Rated AFUE: Btu/Btu
Lifetime:
|
Oil, 90% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.9 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1900 - 3700 | 2900 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Install Furnace:
Before-Component |
After-Component |
Cost |
None
Properties:
- Fuel Type:
- Max Supply Temp: degrees F
- Rated AFUE: Btu/Btu
Lifetime:
|
Oil, 94% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.94 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 2500 - 4800 | 3700 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Install Furnace:
Before-Component |
After-Component |
Cost |
None
Properties:
- Fuel Type:
- Max Supply Temp: degrees F
- Rated AFUE: Btu/Btu
Lifetime:
|
Oil, 95% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.95 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 2600 - 5000 | 3900 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Install Furnace:
Before-Component |
After-Component |
Cost |
None
Properties:
- Fuel Type:
- Max Supply Temp: degrees F
- Rated AFUE: Btu/Btu
Lifetime:
|
Oil, 96% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.96 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 2400 - 5300 | 4000 |
$/kBtuh Input | 2.3 - 5 | 3.9 |
|
Install Furnace:
Before-Component |
After-Component |
Cost |
None
Properties:
- Fuel Type:
- Max Supply Temp: degrees F
- Rated AFUE: Btu/Btu
Lifetime:
|
Propane, 78% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
$/unit | 820 - 1700 | 1300 |
|
Install Furnace:
Before-Component |
After-Component |
Cost |
None
Properties:
- Fuel Type:
- Max Supply Temp: degrees F
- Rated AFUE: Btu/Btu
Lifetime:
|
Propane, 80% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Meets Federal Standard 2015
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1000 - 2000 | 1600 |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
|
Install Furnace:
Before-Component |
After-Component |
Cost |
None
Properties:
- Fuel Type:
- Max Supply Temp: degrees F
- Rated AFUE: Btu/Btu
Lifetime:
|
Propane, 82% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.82 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1200 - 2400 | 1800 |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
|
Install Furnace:
Before-Component |
After-Component |
Cost |
None
Properties:
- Fuel Type:
- Max Supply Temp: degrees F
- Rated AFUE: Btu/Btu
Lifetime:
|
Propane, 90% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.9 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 1900 - 3700 | 2900 |
|
Install Furnace:
Before-Component |
After-Component |
Cost |
None
Properties:
- Fuel Type:
- Max Supply Temp: degrees F
- Rated AFUE: Btu/Btu
Lifetime:
|
Propane, 92% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.92 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 2100 - 4200 | 3200 |
|
Install Furnace:
Before-Component |
After-Component |
Cost |
None
Properties:
- Fuel Type:
- Max Supply Temp: degrees F
- Rated AFUE: Btu/Btu
Lifetime:
|
Propane, 94% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.94 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 2400 - 4600 | 3500 |
|
Install Furnace:
Before-Component |
After-Component |
Cost |
None
Properties:
- Fuel Type:
- Max Supply Temp: degrees F
- Rated AFUE: Btu/Btu
Lifetime:
|
Propane, 95% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.95 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 540 - 1200 | 900 |
|
Install Furnace:
Before-Component |
After-Component |
Cost |
None
Properties:
- Fuel Type:
- Max Supply Temp: degrees F
- Rated AFUE: Btu/Btu
Lifetime:
|
Propane, 96% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.96 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 2600 - 5000 | 3900 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 72% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.72 Btu/Btu
Lifetime:
|
Electric, 100% AFUE
Properties:
- Fuel Type: electric
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 1.0 Btu/Btu
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1000 - 2100 | 1600 |
$/kBtuh Input | 35 - 65 | 50 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 72% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.72 Btu/Btu
Lifetime:
|
Gas, 78% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1200 - 2400 | 1800 |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 72% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.72 Btu/Btu
Lifetime:
|
Gas, 80% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Meets Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1200 - 2400 | 1900 |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 72% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.72 Btu/Btu
Lifetime:
|
Gas, 90% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.9 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 1300 - 2700 | 2100 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 72% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.72 Btu/Btu
Lifetime:
|
Gas, 92.5% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.925 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 1500 - 3000 | 2300 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 72% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.72 Btu/Btu
Lifetime:
|
Gas, 95% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.95 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 1700 - 3300 | 2500 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 72% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.72 Btu/Btu
Lifetime:
|
Gas, 96% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.96 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1700 - 3400 | 2600 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 72% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.72 Btu/Btu
Lifetime:
|
Gas, 98% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.98 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1900 - 3600 | 2800 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Remove Furnace:
Before-Component |
After-Component |
Cost |
Oil, 72% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.72 Btu/Btu
Lifetime:
|
None
Properties:
- Fuel Type:
- Max Supply Temp: degrees F
- Rated AFUE: Btu/Btu
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 140 - 300 | 230 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 72% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.72 Btu/Btu
Lifetime:
|
Oil, 78% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 970 - 2000 | 1500 |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 72% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.72 Btu/Btu
Lifetime:
|
Oil, 80% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1100 - 2300 | 1800 |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 72% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.72 Btu/Btu
Lifetime:
|
Oil, 85% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.85 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1600 - 3200 | 2500 |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 72% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.72 Btu/Btu
Lifetime:
|
Oil, 90% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.9 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 2100 - 4000 | 3100 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 72% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.72 Btu/Btu
Lifetime:
|
Oil, 94% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.94 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 2600 - 5100 | 3900 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 72% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.72 Btu/Btu
Lifetime:
|
Oil, 95% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.95 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 2800 - 5300 | 4100 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 72% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.72 Btu/Btu
Lifetime:
|
Oil, 96% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.96 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 2600 - 5600 | 4300 |
$/kBtuh Input | 2.3 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 72% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.72 Btu/Btu
Lifetime:
|
Propane, 78% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 970 - 2000 | 1500 |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 72% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.72 Btu/Btu
Lifetime:
|
Propane, 80% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Meets Federal Standard 2015
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1100 - 2300 | 1800 |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 72% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.72 Btu/Btu
Lifetime:
|
Propane, 82% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.82 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
$/unit | 1300 - 2700 | 2100 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 72% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.72 Btu/Btu
Lifetime:
|
Propane, 90% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.9 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 2100 - 4000 | 3100 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 72% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.72 Btu/Btu
Lifetime:
|
Propane, 92% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.92 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 2300 - 4500 | 3400 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 72% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.72 Btu/Btu
Lifetime:
|
Propane, 94% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.94 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 2500 - 4900 | 3800 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 72% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.72 Btu/Btu
Lifetime:
|
Propane, 95% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.95 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 680 - 1500 | 1100 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 72% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.72 Btu/Btu
Lifetime:
|
Propane, 96% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.96 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 2800 - 5300 | 4100 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 76% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.76 Btu/Btu
Lifetime:
|
Electric, 100% AFUE
Properties:
- Fuel Type: electric
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 1.0 Btu/Btu
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 35 - 65 | 50 |
$/unit | 1000 - 2100 | 1600 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 76% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.76 Btu/Btu
Lifetime:
|
Gas, 78% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
$/unit | 1200 - 2400 | 1800 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 76% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.76 Btu/Btu
Lifetime:
|
Gas, 80% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Meets Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
$/unit | 1200 - 2400 | 1900 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 76% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.76 Btu/Btu
Lifetime:
|
Gas, 90% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.9 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1300 - 2700 | 2100 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 76% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.76 Btu/Btu
Lifetime:
|
Gas, 92.5% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.925 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1500 - 3000 | 2300 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 76% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.76 Btu/Btu
Lifetime:
|
Gas, 95% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.95 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 1700 - 3300 | 2500 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 76% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.76 Btu/Btu
Lifetime:
|
Gas, 96% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.96 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 1700 - 3400 | 2600 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 76% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.76 Btu/Btu
Lifetime:
|
Gas, 98% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.98 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1900 - 3600 | 2800 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Remove Furnace:
Before-Component |
After-Component |
Cost |
Oil, 76% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.76 Btu/Btu
Lifetime:
|
None
Properties:
- Fuel Type:
- Max Supply Temp: degrees F
- Rated AFUE: Btu/Btu
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 140 - 300 | 230 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 76% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.76 Btu/Btu
Lifetime:
|
Oil, 78% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
$/unit | 970 - 2000 | 1500 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 76% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.76 Btu/Btu
Lifetime:
|
Oil, 80% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
$/unit | 1100 - 2300 | 1800 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 76% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.76 Btu/Btu
Lifetime:
|
Oil, 85% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.85 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1600 - 3200 | 2500 |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 76% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.76 Btu/Btu
Lifetime:
|
Oil, 90% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.9 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 2100 - 4000 | 3100 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 76% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.76 Btu/Btu
Lifetime:
|
Oil, 94% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.94 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 2600 - 5100 | 3900 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 76% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.76 Btu/Btu
Lifetime:
|
Oil, 95% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.95 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 2800 - 5300 | 4100 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 76% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.76 Btu/Btu
Lifetime:
|
Oil, 96% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.96 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 2600 - 5600 | 4300 |
$/kBtuh Input | 2.3 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 76% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.76 Btu/Btu
Lifetime:
|
Propane, 78% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
$/unit | 970 - 2000 | 1500 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 76% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.76 Btu/Btu
Lifetime:
|
Propane, 80% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Meets Federal Standard 2015
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1100 - 2300 | 1800 |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 76% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.76 Btu/Btu
Lifetime:
|
Propane, 82% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.82 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
$/unit | 1300 - 2700 | 2100 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 76% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.76 Btu/Btu
Lifetime:
|
Propane, 90% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.9 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 2100 - 4000 | 3100 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 76% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.76 Btu/Btu
Lifetime:
|
Propane, 92% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.92 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 2300 - 4500 | 3400 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 76% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.76 Btu/Btu
Lifetime:
|
Propane, 94% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.94 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 2500 - 4900 | 3800 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 76% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.76 Btu/Btu
Lifetime:
|
Propane, 95% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.95 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 680 - 1500 | 1100 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 76% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.76 Btu/Btu
Lifetime:
|
Propane, 96% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.96 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 2800 - 5300 | 4100 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 78% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Electric, 100% AFUE
Properties:
- Fuel Type: electric
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 1.0 Btu/Btu
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 35 - 65 | 50 |
$/unit | 1000 - 2100 | 1600 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 78% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Gas, 78% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1200 - 2400 | 1800 |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 78% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Gas, 80% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Meets Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1200 - 2400 | 1900 |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 78% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Gas, 90% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.9 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 1300 - 2700 | 2100 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 78% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Gas, 92.5% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.925 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1500 - 3000 | 2300 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 78% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Gas, 95% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.95 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 1700 - 3300 | 2500 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 78% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Gas, 96% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.96 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 1700 - 3400 | 2600 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 78% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Gas, 98% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.98 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 1900 - 3600 | 2800 |
|
Remove Furnace:
Before-Component |
After-Component |
Cost |
Oil, 78% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
None
Properties:
- Fuel Type:
- Max Supply Temp: degrees F
- Rated AFUE: Btu/Btu
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 140 - 300 | 230 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 78% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Oil, 78% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
$/unit | 970 - 2000 | 1500 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 78% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Oil, 80% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1100 - 2300 | 1800 |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 78% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Oil, 85% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.85 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
$/unit | 1600 - 3200 | 2500 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 78% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Oil, 90% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.9 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 2100 - 4000 | 3100 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 78% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Oil, 94% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.94 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 2600 - 5100 | 3900 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 78% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Oil, 95% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.95 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 2800 - 5300 | 4100 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 78% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Oil, 96% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.96 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.3 - 5 | 3.9 |
$/unit | 2600 - 5600 | 4300 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 78% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Propane, 78% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 970 - 2000 | 1500 |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 78% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Propane, 80% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Meets Federal Standard 2015
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
$/unit | 1100 - 2300 | 1800 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 78% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Propane, 82% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.82 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1300 - 2700 | 2100 |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 78% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Propane, 90% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.9 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 2100 - 4000 | 3100 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 78% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Propane, 92% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.92 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 2300 - 4500 | 3400 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 78% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Propane, 94% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.94 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 2500 - 4900 | 3800 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 78% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Propane, 95% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.95 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 680 - 1500 | 1100 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 78% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Propane, 96% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.96 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 2800 - 5300 | 4100 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 80% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
Lifetime:
|
Electric, 100% AFUE
Properties:
- Fuel Type: electric
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 1.0 Btu/Btu
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1000 - 2100 | 1600 |
$/kBtuh Input | 35 - 65 | 50 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 80% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
Lifetime:
|
Gas, 78% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
$/unit | 1200 - 2400 | 1800 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 80% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
Lifetime:
|
Gas, 80% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Meets Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
$/unit | 1200 - 2400 | 1900 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 80% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
Lifetime:
|
Gas, 90% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.9 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 1300 - 2700 | 2100 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 80% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
Lifetime:
|
Gas, 92.5% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.925 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1500 - 3000 | 2300 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 80% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
Lifetime:
|
Gas, 95% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.95 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 1700 - 3300 | 2500 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 80% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
Lifetime:
|
Gas, 96% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.96 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 1700 - 3400 | 2600 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 80% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
Lifetime:
|
Gas, 98% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.98 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 1900 - 3600 | 2800 |
|
Remove Furnace:
Before-Component |
After-Component |
Cost |
Oil, 80% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
Lifetime:
|
None
Properties:
- Fuel Type:
- Max Supply Temp: degrees F
- Rated AFUE: Btu/Btu
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 140 - 300 | 230 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 80% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
Lifetime:
|
Oil, 80% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1100 - 2300 | 1800 |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 80% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
Lifetime:
|
Oil, 85% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.85 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1600 - 3200 | 2500 |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 80% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
Lifetime:
|
Oil, 90% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.9 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 2100 - 4000 | 3100 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 80% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
Lifetime:
|
Oil, 94% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.94 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 2600 - 5100 | 3900 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 80% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
Lifetime:
|
Oil, 95% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.95 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 2800 - 5300 | 4100 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 80% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
Lifetime:
|
Oil, 96% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.96 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.3 - 5 | 3.9 |
$/unit | 2600 - 5600 | 4300 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 80% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
Lifetime:
|
Propane, 78% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
$/unit | 970 - 2000 | 1500 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 80% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
Lifetime:
|
Propane, 80% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Meets Federal Standard 2015
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1100 - 2300 | 1800 |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 80% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
Lifetime:
|
Propane, 82% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.82 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
$/unit | 1300 - 2700 | 2100 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 80% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
Lifetime:
|
Propane, 90% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.9 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 2100 - 4000 | 3100 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 80% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
Lifetime:
|
Propane, 92% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.92 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 2300 - 4500 | 3400 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 80% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
Lifetime:
|
Propane, 94% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.94 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 2500 - 4900 | 3800 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 80% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
Lifetime:
|
Propane, 95% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.95 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 680 - 1500 | 1100 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 80% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
Lifetime:
|
Propane, 96% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.96 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 2800 - 5300 | 4100 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 85% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.85 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Electric, 100% AFUE
Properties:
- Fuel Type: electric
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 1.0 Btu/Btu
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 35 - 65 | 50 |
$/unit | 1000 - 2100 | 1600 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 85% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.85 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Gas, 78% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
$/unit | 1200 - 2400 | 1800 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 85% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.85 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Gas, 80% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Meets Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
$/unit | 1200 - 2400 | 1900 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 85% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.85 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Gas, 90% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.9 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1300 - 2700 | 2100 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 85% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.85 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Gas, 92.5% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.925 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1500 - 3000 | 2300 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 85% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.85 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Gas, 95% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.95 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 1700 - 3300 | 2500 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 85% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.85 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Gas, 96% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.96 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 1700 - 3400 | 2600 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 85% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.85 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Gas, 98% AFUE
Properties:
- Fuel Type: gas
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.98 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1900 - 3600 | 2800 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Remove Furnace:
Before-Component |
After-Component |
Cost |
Oil, 85% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.85 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
None
Properties:
- Fuel Type:
- Max Supply Temp: degrees F
- Rated AFUE: Btu/Btu
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 140 - 300 | 230 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 85% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.85 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Oil, 85% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.85 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1600 - 3200 | 2500 |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 85% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.85 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Oil, 90% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.9 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 2100 - 4000 | 3100 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 85% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.85 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Oil, 94% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.94 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/kBtuh Input | 2.7 - 5 | 3.9 |
$/unit | 2600 - 5100 | 3900 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 85% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.85 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Oil, 95% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.95 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Exceeds Energy Star 2006
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 2800 - 5300 | 4100 |
$/kBtuh Input | 2.7 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 85% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.85 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Oil, 96% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.96 Btu/Btu
Performance Standards:
- Exceeds Energy Star 2006
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 2600 - 5600 | 4300 |
$/kBtuh Input | 2.3 - 5 | 3.9 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 85% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.85 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Propane, 78% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.78 Btu/Btu
Performance Standards:
- Meets Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 970 - 2000 | 1500 |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 85% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.85 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Propane, 80% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.8 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Meets Federal Standard 2015
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1100 - 2300 | 1800 |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 85% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.85 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Propane, 82% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.82 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 2015
- Exceeds Federal Standard 1992
Lifetime:
|
Measure Cost
Units | Range | Average |
$/unit | 1300 - 2700 | 2100 |
$/kBtuh Input | 1.9 - 3.5 | 2.7 |
|
Replace Furnace:
Before-Component |
After-Component |
Cost |
Oil, 85% AFUE
Properties:
- Fuel Type: oil
- Max Supply Temp: 120.0 degrees F
- Rated AFUE: 0.85 Btu/Btu
Performance Standards:
- Exceeds Federal Standard 1992
- Exceeds Federal Standard 2015
- Meets Energy Star 2006
Lifetime:
|
Propane, 90% AFUE
Properties:
- Fuel Type: propane
- Max Supply Temp: 120.0 degrees F