Here you will find the data for Windows measures available in the National Residential Efficiency Measures Database. Each measure consists of a before-component, an after-component, and the estimated cost to implement the measure. The measures are listed alphabetically based upon the name of the before-component. Where multiple costs are indicated they must be combined to obtain total measure cost (e.g., fixed ($) and normalized ($/sf) costs).

Cost Drivers

There are many factors that influence the ultimate cost of Windows measures. The application of the average measure costs displayed below to any particular home is discouraged. Examples of the kinds of issues that can influence the cost of Windows measures include:
  • Prevailing local wages
  • Drive time
  • Local code requirements
  • Access
  • Existing construction and materials
  • Moisture issues present
  • Presence of hazardous materials
  • Extent of preparation

Viewing 516 Windows Measure(s) of 516

Replace Window:

Before-Component After-Component Cost

Clear, Double, Metal, Air

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • Storm Sash:
  • U-Value: 0.76 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Clear, Double, Metal, Air

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • Storm Sash:
  • U-Value: 0.76 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window21 - 4233

Replace Window:

Before-Component After-Component Cost

Clear, Double, Metal, Air

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • Storm Sash:
  • U-Value: 0.76 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Clear, Double, Non-metal, Air

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.49 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window21 - 4333

Replace Window:

Before-Component After-Component Cost

Clear, Double, Metal, Air

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • Storm Sash:
  • U-Value: 0.76 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Clear, Double, Thermal-Break, Air

Properties:

  • Film:
  • Frame Material: metal with thermal breaks
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.62
  • Storm Sash:
  • U-Value: 0.63 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window21 - 4233

Replace Window:

Before-Component After-Component Cost

Clear, Double, Metal, Air

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • Storm Sash:
  • U-Value: 0.76 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Air, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.32 Btu/h-ft^2-R

Performance Standards:

  • Meets IECC 2012 (5C, 6B, 7, 5B, 5A, 4C, 6A, 6C, 8)
  • Exceeds IECC 2009 (5C, 4B, 7, 5B, 4A, 5A, 4C, 6A, 6C, 8, 6B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window28 - 5744

Replace Window:

Before-Component After-Component Cost

Clear, Double, Metal, Air

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • Storm Sash:
  • U-Value: 0.76 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Air, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (8, 6B, 7, 6A, 6C, 5A, 4C, 4A, 5B, 4B, 5C)
  • Exceeds IECC 2009 (8, 6B, 7, 6A, 6C, 5A, 4C, 5B, 4A, 5C, 4B)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window30 - 6046

Replace Window:

Before-Component After-Component Cost

Clear, Double, Metal, Air

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • Storm Sash:
  • U-Value: 0.76 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Air, M-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (5B, 5C, 8, 6B, 7, 6A, 6C, 5A, 4C)
  • Exceeds IECC 2009 (8, 6B, 7, 6A, 6C, 5A, 4C, 5B, 4A, 5C, 4B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window29 - 5845

Replace Window:

Before-Component After-Component Cost

Clear, Double, Metal, Air

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • Storm Sash:
  • U-Value: 0.76 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (5C, 4B, 7, 5B, 4A, 5A, 4C, 6A, 6C, 8, 6B)
  • Exceeds IECC 2012 (5C, 6B, 7, 5B, 5A, 4C, 6A, 6C, 8)
  • Exceeds Energy Star 2010 (Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window30 - 6046

Replace Window:

Before-Component After-Component Cost

Clear, Double, Metal, Air

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • Storm Sash:
  • U-Value: 0.76 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.26 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2009 (6A, 4C, 5B, 4A, 5C, 8, 4B, 6B, 7, 6C, 5A)
  • Exceeds IECC 2012 (6A, 4C, 4A, 5B, 4B, 5C, 8, 6B, 7, 6C, 5A)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window32 - 6349

Replace Window:

Before-Component After-Component Cost

Clear, Double, Metal, Air

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • Storm Sash:
  • U-Value: 0.76 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Arg, M-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (4C, 6A, 6C, 5C, 8, 6B, 7, 5B, 5A)
  • Exceeds IECC 2009 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)
  • Exceeds Energy Star 2010 (Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window31 - 6248

Replace Window:

Before-Component After-Component Cost

Clear, Double, Metal, Air

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • Storm Sash:
  • U-Value: 0.76 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Non-metal, Air, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.39 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window21 - 4434

Replace Window:

Before-Component After-Component Cost

Clear, Double, Metal, Air

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • Storm Sash:
  • U-Value: 0.76 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Non-metal, Air, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (3B, 2C, 3A, 1B, 1A, 3C, 2B, 1C, 2A)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window23 - 4736

Replace Window:

Before-Component After-Component Cost

Clear, Double, Metal, Air

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • Storm Sash:
  • U-Value: 0.76 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Non-metal, Air, M-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.38 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window22 - 4535

Replace Window:

Before-Component After-Component Cost

Clear, Double, Metal, Air

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • Storm Sash:
  • U-Value: 0.76 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Non-metal, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window23 - 4736

Replace Window:

Before-Component After-Component Cost

Clear, Double, Metal, Air

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • Storm Sash:
  • U-Value: 0.76 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Non-metal, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.34 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (South-Central)
  • Exceeds IECC 2012 (4A, 4B)
  • Exceeds IECC 2009 (8, 6A, 4C, 2A, 3B, 5B, 4A, 2B, 1C, 7, 1B, 5C, 4B, 1A, 3C, 6C, 2C, 3A, 5A, 6B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window25 - 5039

Replace Window:

Before-Component After-Component Cost

Clear, Double, Metal, Air

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • Storm Sash:
  • U-Value: 0.76 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Non-metal, Arg, M-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.35 Btu/h-ft^2-R

Performance Standards:

  • Meets IECC 2009 (5C, 4B, 7, 5B, 4A, 5A, 4C, 6A, 6C, 8, 6B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window24 - 4938

Replace Window:

Before-Component After-Component Cost

Clear, Double, Metal, Air

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • Storm Sash:
  • U-Value: 0.76 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Air, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.21 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2009 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)
  • Exceeds IECC 2012 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window36 - 7255

Replace Window:

Before-Component After-Component Cost

Clear, Double, Metal, Air

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • Storm Sash:
  • U-Value: 0.76 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Air, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.19 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (North-Central, Southern, Northern, South-Central)
  • Exceeds IECC 2009 (6B, 6A, 3B, 2A, 4C, 1C, 2B, 5B, 4A, 1A, 3C, 5C, 4B, 1B, 7, 2C, 3A, 6C, 5A, 8)
  • Exceeds IECC 2012 (8, 6B, 7, 6A, 6C, 5A, 4C, 4A, 5B, 4B, 5C)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window37 - 7256

Replace Window:

Before-Component After-Component Cost

Clear, Double, Metal, Air

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • Storm Sash:
  • U-Value: 0.76 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.18 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (8, 6B, 5B, 4A, 5A, 4C, 6A, 6C, 5C, 4B, 7)
  • Exceeds IECC 2009 (8, 6B, 5B, 4A, 5A, 4C, 6A, 6C, 5C, 4B, 7)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window38 - 7457

Replace Window:

Before-Component After-Component Cost

Clear, Double, Metal, Air

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • Storm Sash:
  • U-Value: 0.76 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.17 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (Northern, North-Central, Southern, South-Central)
  • Exceeds IECC 2009 (6C, 5A, 2B, 5B, 4A, 1C, 1B, 7, 1A, 3C, 5C, 4B, 6A, 2A, 4C, 3B, 6B, 8, 2C, 3A)
  • Exceeds IECC 2012 (6C, 5A, 4A, 5B, 6B, 7, 4B, 5C, 8, 6A, 4C)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window38 - 7557

Replace Window:

Before-Component After-Component Cost

Clear, Double, Metal, Air

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • Storm Sash:
  • U-Value: 0.76 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Triple, Non-metal, Air, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (4C, 6A, 6C, 4B, 5C, 8, 6B, 7, 4A, 5B, 5A)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2009 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)
  • Exceeds Energy Star 2010 (North-Central)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window29 - 5945

Replace Window:

Before-Component After-Component Cost

Clear, Double, Metal, Air

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • Storm Sash:
  • U-Value: 0.76 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Triple, Non-metal, Air, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (South-Central, North-Central, Southern, Northern)
  • Exceeds IECC 2012 (4B, 5C, 7, 4A, 5B, 5A, 4C, 6A, 6C, 8, 6B)
  • Exceeds IECC 2009 (1A, 3C, 7, 4A, 5A, 2C, 3A, 6C, 8, 6B, 3B, 2A, 4C, 6A, 5C, 4B, 1B, 1C, 2B, 5B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window30 - 6046

Replace Window:

Before-Component After-Component Cost

Clear, Double, Metal, Air

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • Storm Sash:
  • U-Value: 0.76 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Triple, Non-metal, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (5B, 4A, 5C, 4B, 6B, 7, 6A, 6C, 5A, 4C, 8)
  • Exceeds IECC 2012 (4A, 5B, 4B, 5C, 6B, 7, 6A, 6C, 5A, 4C, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window31 - 6147

Replace Window:

Before-Component After-Component Cost

Clear, Double, Metal, Air

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • Storm Sash:
  • U-Value: 0.76 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Triple, Non-metal, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (6B, 3B, 2A, 4C, 6A, 1A, 3C, 5C, 4B, 1B, 7, 1C, 2B, 5B, 4A, 5A, 2C, 3A, 6C, 8)
  • Exceeds IECC 2012 (8, 6B, 4A, 5B, 5A, 4C, 6A, 6C, 4B, 5C, 7)
  • Exceeds Energy Star 2010 (South-Central, North-Central, Southern, Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window31 - 6247

Replace Window:

Before-Component After-Component Cost

Clear, Double, Non-metal, Air

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.49 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Clear, Double, Non-metal, Air

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.49 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window21 - 4333

Replace Window:

Before-Component After-Component Cost

Clear, Double, Non-metal, Air

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.49 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Air, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.32 Btu/h-ft^2-R

Performance Standards:

  • Meets IECC 2012 (5C, 6B, 7, 5B, 5A, 4C, 6A, 6C, 8)
  • Exceeds IECC 2009 (5C, 4B, 7, 5B, 4A, 5A, 4C, 6A, 6C, 8, 6B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window28 - 5744

Replace Window:

Before-Component After-Component Cost

Clear, Double, Non-metal, Air

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.49 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Air, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (8, 6B, 7, 6A, 6C, 5A, 4C, 4A, 5B, 4B, 5C)
  • Exceeds IECC 2009 (8, 6B, 7, 6A, 6C, 5A, 4C, 5B, 4A, 5C, 4B)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window30 - 6046

Replace Window:

Before-Component After-Component Cost

Clear, Double, Non-metal, Air

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.49 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Air, M-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (5B, 5C, 8, 6B, 7, 6A, 6C, 5A, 4C)
  • Exceeds IECC 2009 (8, 6B, 7, 6A, 6C, 5A, 4C, 5B, 4A, 5C, 4B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window29 - 5845

Replace Window:

Before-Component After-Component Cost

Clear, Double, Non-metal, Air

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.49 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (5C, 4B, 7, 5B, 4A, 5A, 4C, 6A, 6C, 8, 6B)
  • Exceeds IECC 2012 (5C, 6B, 7, 5B, 5A, 4C, 6A, 6C, 8)
  • Exceeds Energy Star 2010 (Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window30 - 6046

Replace Window:

Before-Component After-Component Cost

Clear, Double, Non-metal, Air

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.49 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.26 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2009 (6A, 4C, 5B, 4A, 5C, 8, 4B, 6B, 7, 6C, 5A)
  • Exceeds IECC 2012 (6A, 4C, 4A, 5B, 4B, 5C, 8, 6B, 7, 6C, 5A)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window32 - 6349

Replace Window:

Before-Component After-Component Cost

Clear, Double, Non-metal, Air

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.49 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Arg, M-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (4C, 6A, 6C, 5C, 8, 6B, 7, 5B, 5A)
  • Exceeds IECC 2009 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)
  • Exceeds Energy Star 2010 (Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window31 - 6248

Replace Window:

Before-Component After-Component Cost

Clear, Double, Non-metal, Air

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.49 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Non-metal, Air, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.39 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window21 - 4434

Replace Window:

Before-Component After-Component Cost

Clear, Double, Non-metal, Air

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.49 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Non-metal, Air, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (3B, 2C, 3A, 1B, 1A, 3C, 2B, 1C, 2A)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window23 - 4736

Replace Window:

Before-Component After-Component Cost

Clear, Double, Non-metal, Air

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.49 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Non-metal, Air, M-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.38 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window22 - 4535

Replace Window:

Before-Component After-Component Cost

Clear, Double, Non-metal, Air

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.49 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Non-metal, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window23 - 4736

Replace Window:

Before-Component After-Component Cost

Clear, Double, Non-metal, Air

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.49 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Non-metal, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.34 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (South-Central)
  • Exceeds IECC 2012 (4A, 4B)
  • Exceeds IECC 2009 (8, 6A, 4C, 2A, 3B, 5B, 4A, 2B, 1C, 7, 1B, 5C, 4B, 1A, 3C, 6C, 2C, 3A, 5A, 6B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window25 - 5039

Replace Window:

Before-Component After-Component Cost

Clear, Double, Non-metal, Air

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.49 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Non-metal, Arg, M-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.35 Btu/h-ft^2-R

Performance Standards:

  • Meets IECC 2009 (5C, 4B, 7, 5B, 4A, 5A, 4C, 6A, 6C, 8, 6B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window24 - 4938

Replace Window:

Before-Component After-Component Cost

Clear, Double, Non-metal, Air

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.49 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Air, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.21 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2009 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)
  • Exceeds IECC 2012 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window36 - 7255

Replace Window:

Before-Component After-Component Cost

Clear, Double, Non-metal, Air

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.49 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Air, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.19 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (North-Central, Southern, Northern, South-Central)
  • Exceeds IECC 2009 (6B, 6A, 3B, 2A, 4C, 1C, 2B, 5B, 4A, 1A, 3C, 5C, 4B, 1B, 7, 2C, 3A, 6C, 5A, 8)
  • Exceeds IECC 2012 (8, 6B, 7, 6A, 6C, 5A, 4C, 4A, 5B, 4B, 5C)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window37 - 7256

Replace Window:

Before-Component After-Component Cost

Clear, Double, Non-metal, Air

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.49 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.18 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (8, 6B, 5B, 4A, 5A, 4C, 6A, 6C, 5C, 4B, 7)
  • Exceeds IECC 2009 (8, 6B, 5B, 4A, 5A, 4C, 6A, 6C, 5C, 4B, 7)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window38 - 7457

Replace Window:

Before-Component After-Component Cost

Clear, Double, Non-metal, Air

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.49 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.17 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (Northern, North-Central, Southern, South-Central)
  • Exceeds IECC 2009 (6C, 5A, 2B, 5B, 4A, 1C, 1B, 7, 1A, 3C, 5C, 4B, 6A, 2A, 4C, 3B, 6B, 8, 2C, 3A)
  • Exceeds IECC 2012 (6C, 5A, 4A, 5B, 6B, 7, 4B, 5C, 8, 6A, 4C)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window38 - 7557

Replace Window:

Before-Component After-Component Cost

Clear, Double, Non-metal, Air

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.49 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Triple, Non-metal, Air, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (4C, 6A, 6C, 4B, 5C, 8, 6B, 7, 4A, 5B, 5A)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2009 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)
  • Exceeds Energy Star 2010 (North-Central)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window29 - 5945

Replace Window:

Before-Component After-Component Cost

Clear, Double, Non-metal, Air

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.49 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Triple, Non-metal, Air, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (South-Central, North-Central, Southern, Northern)
  • Exceeds IECC 2012 (4B, 5C, 7, 4A, 5B, 5A, 4C, 6A, 6C, 8, 6B)
  • Exceeds IECC 2009 (1A, 3C, 7, 4A, 5A, 2C, 3A, 6C, 8, 6B, 3B, 2A, 4C, 6A, 5C, 4B, 1B, 1C, 2B, 5B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window30 - 6046

Replace Window:

Before-Component After-Component Cost

Clear, Double, Non-metal, Air

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.49 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Triple, Non-metal, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (5B, 4A, 5C, 4B, 6B, 7, 6A, 6C, 5A, 4C, 8)
  • Exceeds IECC 2012 (4A, 5B, 4B, 5C, 6B, 7, 6A, 6C, 5A, 4C, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window31 - 6147

Replace Window:

Before-Component After-Component Cost

Clear, Double, Non-metal, Air

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.49 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Triple, Non-metal, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (6B, 3B, 2A, 4C, 6A, 1A, 3C, 5C, 4B, 1B, 7, 1C, 2B, 5B, 4A, 5A, 2C, 3A, 6C, 8)
  • Exceeds IECC 2012 (8, 6B, 4A, 5B, 5A, 4C, 6A, 6C, 4B, 5C, 7)
  • Exceeds Energy Star 2010 (South-Central, North-Central, Southern, Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window31 - 6247

Replace Window:

Before-Component After-Component Cost

Clear, Double, Thermal-Break, Air

Properties:

  • Film:
  • Frame Material: metal with thermal breaks
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.62
  • Storm Sash:
  • U-Value: 0.63 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Clear, Double, Non-metal, Air

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.49 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window21 - 4333

Replace Window:

Before-Component After-Component Cost

Clear, Double, Thermal-Break, Air

Properties:

  • Film:
  • Frame Material: metal with thermal breaks
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.62
  • Storm Sash:
  • U-Value: 0.63 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Clear, Double, Thermal-Break, Air

Properties:

  • Film:
  • Frame Material: metal with thermal breaks
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.62
  • Storm Sash:
  • U-Value: 0.63 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window21 - 4233

Replace Window:

Before-Component After-Component Cost

Clear, Double, Thermal-Break, Air

Properties:

  • Film:
  • Frame Material: metal with thermal breaks
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.62
  • Storm Sash:
  • U-Value: 0.63 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Air, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.32 Btu/h-ft^2-R

Performance Standards:

  • Meets IECC 2012 (5C, 6B, 7, 5B, 5A, 4C, 6A, 6C, 8)
  • Exceeds IECC 2009 (5C, 4B, 7, 5B, 4A, 5A, 4C, 6A, 6C, 8, 6B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window28 - 5744

Replace Window:

Before-Component After-Component Cost

Clear, Double, Thermal-Break, Air

Properties:

  • Film:
  • Frame Material: metal with thermal breaks
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.62
  • Storm Sash:
  • U-Value: 0.63 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Air, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (8, 6B, 7, 6A, 6C, 5A, 4C, 4A, 5B, 4B, 5C)
  • Exceeds IECC 2009 (8, 6B, 7, 6A, 6C, 5A, 4C, 5B, 4A, 5C, 4B)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window30 - 6046

Replace Window:

Before-Component After-Component Cost

Clear, Double, Thermal-Break, Air

Properties:

  • Film:
  • Frame Material: metal with thermal breaks
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.62
  • Storm Sash:
  • U-Value: 0.63 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Air, M-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (5B, 5C, 8, 6B, 7, 6A, 6C, 5A, 4C)
  • Exceeds IECC 2009 (8, 6B, 7, 6A, 6C, 5A, 4C, 5B, 4A, 5C, 4B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window29 - 5845

Replace Window:

Before-Component After-Component Cost

Clear, Double, Thermal-Break, Air

Properties:

  • Film:
  • Frame Material: metal with thermal breaks
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.62
  • Storm Sash:
  • U-Value: 0.63 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (5C, 4B, 7, 5B, 4A, 5A, 4C, 6A, 6C, 8, 6B)
  • Exceeds IECC 2012 (5C, 6B, 7, 5B, 5A, 4C, 6A, 6C, 8)
  • Exceeds Energy Star 2010 (Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window30 - 6046

Replace Window:

Before-Component After-Component Cost

Clear, Double, Thermal-Break, Air

Properties:

  • Film:
  • Frame Material: metal with thermal breaks
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.62
  • Storm Sash:
  • U-Value: 0.63 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.26 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2009 (6A, 4C, 5B, 4A, 5C, 8, 4B, 6B, 7, 6C, 5A)
  • Exceeds IECC 2012 (6A, 4C, 4A, 5B, 4B, 5C, 8, 6B, 7, 6C, 5A)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window32 - 6349

Replace Window:

Before-Component After-Component Cost

Clear, Double, Thermal-Break, Air

Properties:

  • Film:
  • Frame Material: metal with thermal breaks
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.62
  • Storm Sash:
  • U-Value: 0.63 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Arg, M-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (4C, 6A, 6C, 5C, 8, 6B, 7, 5B, 5A)
  • Exceeds IECC 2009 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)
  • Exceeds Energy Star 2010 (Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window31 - 6248

Replace Window:

Before-Component After-Component Cost

Clear, Double, Thermal-Break, Air

Properties:

  • Film:
  • Frame Material: metal with thermal breaks
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.62
  • Storm Sash:
  • U-Value: 0.63 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Non-metal, Air, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.39 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window21 - 4434

Replace Window:

Before-Component After-Component Cost

Clear, Double, Thermal-Break, Air

Properties:

  • Film:
  • Frame Material: metal with thermal breaks
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.62
  • Storm Sash:
  • U-Value: 0.63 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Non-metal, Air, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (3B, 2C, 3A, 1B, 1A, 3C, 2B, 1C, 2A)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window23 - 4736

Replace Window:

Before-Component After-Component Cost

Clear, Double, Thermal-Break, Air

Properties:

  • Film:
  • Frame Material: metal with thermal breaks
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.62
  • Storm Sash:
  • U-Value: 0.63 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Non-metal, Air, M-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.38 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window22 - 4535

Replace Window:

Before-Component After-Component Cost

Clear, Double, Thermal-Break, Air

Properties:

  • Film:
  • Frame Material: metal with thermal breaks
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.62
  • Storm Sash:
  • U-Value: 0.63 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Non-metal, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window23 - 4736

Replace Window:

Before-Component After-Component Cost

Clear, Double, Thermal-Break, Air

Properties:

  • Film:
  • Frame Material: metal with thermal breaks
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.62
  • Storm Sash:
  • U-Value: 0.63 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Non-metal, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.34 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (South-Central)
  • Exceeds IECC 2012 (4A, 4B)
  • Exceeds IECC 2009 (8, 6A, 4C, 2A, 3B, 5B, 4A, 2B, 1C, 7, 1B, 5C, 4B, 1A, 3C, 6C, 2C, 3A, 5A, 6B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window25 - 5039

Replace Window:

Before-Component After-Component Cost

Clear, Double, Thermal-Break, Air

Properties:

  • Film:
  • Frame Material: metal with thermal breaks
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.62
  • Storm Sash:
  • U-Value: 0.63 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Non-metal, Arg, M-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.35 Btu/h-ft^2-R

Performance Standards:

  • Meets IECC 2009 (5C, 4B, 7, 5B, 4A, 5A, 4C, 6A, 6C, 8, 6B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window24 - 4938

Replace Window:

Before-Component After-Component Cost

Clear, Double, Thermal-Break, Air

Properties:

  • Film:
  • Frame Material: metal with thermal breaks
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.62
  • Storm Sash:
  • U-Value: 0.63 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Air, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.21 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2009 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)
  • Exceeds IECC 2012 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window36 - 7255

Replace Window:

Before-Component After-Component Cost

Clear, Double, Thermal-Break, Air

Properties:

  • Film:
  • Frame Material: metal with thermal breaks
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.62
  • Storm Sash:
  • U-Value: 0.63 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Air, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.19 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (North-Central, Southern, Northern, South-Central)
  • Exceeds IECC 2009 (6B, 6A, 3B, 2A, 4C, 1C, 2B, 5B, 4A, 1A, 3C, 5C, 4B, 1B, 7, 2C, 3A, 6C, 5A, 8)
  • Exceeds IECC 2012 (8, 6B, 7, 6A, 6C, 5A, 4C, 4A, 5B, 4B, 5C)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window37 - 7256

Replace Window:

Before-Component After-Component Cost

Clear, Double, Thermal-Break, Air

Properties:

  • Film:
  • Frame Material: metal with thermal breaks
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.62
  • Storm Sash:
  • U-Value: 0.63 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.18 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (8, 6B, 5B, 4A, 5A, 4C, 6A, 6C, 5C, 4B, 7)
  • Exceeds IECC 2009 (8, 6B, 5B, 4A, 5A, 4C, 6A, 6C, 5C, 4B, 7)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window38 - 7457

Replace Window:

Before-Component After-Component Cost

Clear, Double, Thermal-Break, Air

Properties:

  • Film:
  • Frame Material: metal with thermal breaks
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.62
  • Storm Sash:
  • U-Value: 0.63 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.17 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (Northern, North-Central, Southern, South-Central)
  • Exceeds IECC 2009 (6C, 5A, 2B, 5B, 4A, 1C, 1B, 7, 1A, 3C, 5C, 4B, 6A, 2A, 4C, 3B, 6B, 8, 2C, 3A)
  • Exceeds IECC 2012 (6C, 5A, 4A, 5B, 6B, 7, 4B, 5C, 8, 6A, 4C)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window38 - 7557

Replace Window:

Before-Component After-Component Cost

Clear, Double, Thermal-Break, Air

Properties:

  • Film:
  • Frame Material: metal with thermal breaks
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.62
  • Storm Sash:
  • U-Value: 0.63 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Triple, Non-metal, Air, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (4C, 6A, 6C, 4B, 5C, 8, 6B, 7, 4A, 5B, 5A)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2009 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)
  • Exceeds Energy Star 2010 (North-Central)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window29 - 5945

Replace Window:

Before-Component After-Component Cost

Clear, Double, Thermal-Break, Air

Properties:

  • Film:
  • Frame Material: metal with thermal breaks
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.62
  • Storm Sash:
  • U-Value: 0.63 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Triple, Non-metal, Air, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (South-Central, North-Central, Southern, Northern)
  • Exceeds IECC 2012 (4B, 5C, 7, 4A, 5B, 5A, 4C, 6A, 6C, 8, 6B)
  • Exceeds IECC 2009 (1A, 3C, 7, 4A, 5A, 2C, 3A, 6C, 8, 6B, 3B, 2A, 4C, 6A, 5C, 4B, 1B, 1C, 2B, 5B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window30 - 6046

Replace Window:

Before-Component After-Component Cost

Clear, Double, Thermal-Break, Air

Properties:

  • Film:
  • Frame Material: metal with thermal breaks
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.62
  • Storm Sash:
  • U-Value: 0.63 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Triple, Non-metal, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (5B, 4A, 5C, 4B, 6B, 7, 6A, 6C, 5A, 4C, 8)
  • Exceeds IECC 2012 (4A, 5B, 4B, 5C, 6B, 7, 6A, 6C, 5A, 4C, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window31 - 6147

Replace Window:

Before-Component After-Component Cost

Clear, Double, Thermal-Break, Air

Properties:

  • Film:
  • Frame Material: metal with thermal breaks
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.62
  • Storm Sash:
  • U-Value: 0.63 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Triple, Non-metal, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (6B, 3B, 2A, 4C, 6A, 1A, 3C, 5C, 4B, 1B, 7, 1C, 2B, 5B, 4A, 5A, 2C, 3A, 6C, 8)
  • Exceeds IECC 2012 (8, 6B, 4A, 5B, 5A, 4C, 6A, 6C, 4B, 5C, 7)
  • Exceeds Energy Star 2010 (South-Central, North-Central, Southern, Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window31 - 6247

Replace Window:

Before-Component After-Component Cost

Clear, Single, Metal

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.76
  • Storm Sash:
  • U-Value: 1.16 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Clear, Double, Metal, Air

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • Storm Sash:
  • U-Value: 0.76 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window21 - 4233

Replace Window:

Before-Component After-Component Cost

Clear, Single, Metal

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.76
  • Storm Sash:
  • U-Value: 1.16 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Clear, Double, Non-metal, Air

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.49 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window21 - 4333

Replace Window:

Before-Component After-Component Cost

Clear, Single, Metal

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.76
  • Storm Sash:
  • U-Value: 1.16 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Clear, Double, Thermal-Break, Air

Properties:

  • Film:
  • Frame Material: metal with thermal breaks
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.62
  • Storm Sash:
  • U-Value: 0.63 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window21 - 4233

Replace Window:

Before-Component After-Component Cost

Clear, Single, Metal

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.76
  • Storm Sash:
  • U-Value: 1.16 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Air, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.32 Btu/h-ft^2-R

Performance Standards:

  • Meets IECC 2012 (5C, 6B, 7, 5B, 5A, 4C, 6A, 6C, 8)
  • Exceeds IECC 2009 (5C, 4B, 7, 5B, 4A, 5A, 4C, 6A, 6C, 8, 6B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window28 - 5744

Replace Window:

Before-Component After-Component Cost

Clear, Single, Metal

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.76
  • Storm Sash:
  • U-Value: 1.16 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Air, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (8, 6B, 7, 6A, 6C, 5A, 4C, 4A, 5B, 4B, 5C)
  • Exceeds IECC 2009 (8, 6B, 7, 6A, 6C, 5A, 4C, 5B, 4A, 5C, 4B)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window30 - 6046

Replace Window:

Before-Component After-Component Cost

Clear, Single, Metal

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.76
  • Storm Sash:
  • U-Value: 1.16 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Air, M-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (5B, 5C, 8, 6B, 7, 6A, 6C, 5A, 4C)
  • Exceeds IECC 2009 (8, 6B, 7, 6A, 6C, 5A, 4C, 5B, 4A, 5C, 4B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window29 - 5845

Replace Window:

Before-Component After-Component Cost

Clear, Single, Metal

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.76
  • Storm Sash:
  • U-Value: 1.16 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (5C, 4B, 7, 5B, 4A, 5A, 4C, 6A, 6C, 8, 6B)
  • Exceeds IECC 2012 (5C, 6B, 7, 5B, 5A, 4C, 6A, 6C, 8)
  • Exceeds Energy Star 2010 (Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window30 - 6046

Replace Window:

Before-Component After-Component Cost

Clear, Single, Metal

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.76
  • Storm Sash:
  • U-Value: 1.16 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.26 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2009 (6A, 4C, 5B, 4A, 5C, 8, 4B, 6B, 7, 6C, 5A)
  • Exceeds IECC 2012 (6A, 4C, 4A, 5B, 4B, 5C, 8, 6B, 7, 6C, 5A)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window32 - 6349

Replace Window:

Before-Component After-Component Cost

Clear, Single, Metal

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.76
  • Storm Sash:
  • U-Value: 1.16 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Arg, M-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (4C, 6A, 6C, 5C, 8, 6B, 7, 5B, 5A)
  • Exceeds IECC 2009 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)
  • Exceeds Energy Star 2010 (Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window31 - 6248

Replace Window:

Before-Component After-Component Cost

Clear, Single, Metal

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.76
  • Storm Sash:
  • U-Value: 1.16 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Non-metal, Air, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.39 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window21 - 4434

Replace Window:

Before-Component After-Component Cost

Clear, Single, Metal

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.76
  • Storm Sash:
  • U-Value: 1.16 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Non-metal, Air, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (3B, 2C, 3A, 1B, 1A, 3C, 2B, 1C, 2A)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window23 - 4736

Replace Window:

Before-Component After-Component Cost

Clear, Single, Metal

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.76
  • Storm Sash:
  • U-Value: 1.16 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Non-metal, Air, M-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.38 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window22 - 4535

Replace Window:

Before-Component After-Component Cost

Clear, Single, Metal

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.76
  • Storm Sash:
  • U-Value: 1.16 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Non-metal, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window23 - 4736

Replace Window:

Before-Component After-Component Cost

Clear, Single, Metal

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.76
  • Storm Sash:
  • U-Value: 1.16 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Non-metal, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.34 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (South-Central)
  • Exceeds IECC 2012 (4A, 4B)
  • Exceeds IECC 2009 (8, 6A, 4C, 2A, 3B, 5B, 4A, 2B, 1C, 7, 1B, 5C, 4B, 1A, 3C, 6C, 2C, 3A, 5A, 6B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window25 - 5039

Replace Window:

Before-Component After-Component Cost

Clear, Single, Metal

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.76
  • Storm Sash:
  • U-Value: 1.16 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Non-metal, Arg, M-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.35 Btu/h-ft^2-R

Performance Standards:

  • Meets IECC 2009 (5C, 4B, 7, 5B, 4A, 5A, 4C, 6A, 6C, 8, 6B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window24 - 4938

Replace Window:

Before-Component After-Component Cost

Clear, Single, Metal

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.76
  • Storm Sash:
  • U-Value: 1.16 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Air, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.21 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2009 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)
  • Exceeds IECC 2012 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window36 - 7255

Replace Window:

Before-Component After-Component Cost

Clear, Single, Metal

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.76
  • Storm Sash:
  • U-Value: 1.16 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Air, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.19 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (North-Central, Southern, Northern, South-Central)
  • Exceeds IECC 2009 (6B, 6A, 3B, 2A, 4C, 1C, 2B, 5B, 4A, 1A, 3C, 5C, 4B, 1B, 7, 2C, 3A, 6C, 5A, 8)
  • Exceeds IECC 2012 (8, 6B, 7, 6A, 6C, 5A, 4C, 4A, 5B, 4B, 5C)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window37 - 7256

Replace Window:

Before-Component After-Component Cost

Clear, Single, Metal

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.76
  • Storm Sash:
  • U-Value: 1.16 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.18 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (8, 6B, 5B, 4A, 5A, 4C, 6A, 6C, 5C, 4B, 7)
  • Exceeds IECC 2009 (8, 6B, 5B, 4A, 5A, 4C, 6A, 6C, 5C, 4B, 7)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window38 - 7457

Replace Window:

Before-Component After-Component Cost

Clear, Single, Metal

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.76
  • Storm Sash:
  • U-Value: 1.16 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.17 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (Northern, North-Central, Southern, South-Central)
  • Exceeds IECC 2009 (6C, 5A, 2B, 5B, 4A, 1C, 1B, 7, 1A, 3C, 5C, 4B, 6A, 2A, 4C, 3B, 6B, 8, 2C, 3A)
  • Exceeds IECC 2012 (6C, 5A, 4A, 5B, 6B, 7, 4B, 5C, 8, 6A, 4C)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window38 - 7557

Replace Window:

Before-Component After-Component Cost

Clear, Single, Metal

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.76
  • Storm Sash:
  • U-Value: 1.16 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Triple, Non-metal, Air, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (4C, 6A, 6C, 4B, 5C, 8, 6B, 7, 4A, 5B, 5A)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2009 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)
  • Exceeds Energy Star 2010 (North-Central)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window29 - 5945

Replace Window:

Before-Component After-Component Cost

Clear, Single, Metal

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.76
  • Storm Sash:
  • U-Value: 1.16 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Triple, Non-metal, Air, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (South-Central, North-Central, Southern, Northern)
  • Exceeds IECC 2012 (4B, 5C, 7, 4A, 5B, 5A, 4C, 6A, 6C, 8, 6B)
  • Exceeds IECC 2009 (1A, 3C, 7, 4A, 5A, 2C, 3A, 6C, 8, 6B, 3B, 2A, 4C, 6A, 5C, 4B, 1B, 1C, 2B, 5B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window30 - 6046

Replace Window:

Before-Component After-Component Cost

Clear, Single, Metal

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.76
  • Storm Sash:
  • U-Value: 1.16 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Triple, Non-metal, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (5B, 4A, 5C, 4B, 6B, 7, 6A, 6C, 5A, 4C, 8)
  • Exceeds IECC 2012 (4A, 5B, 4B, 5C, 6B, 7, 6A, 6C, 5A, 4C, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window31 - 6147

Replace Window:

Before-Component After-Component Cost

Clear, Single, Metal

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.76
  • Storm Sash:
  • U-Value: 1.16 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Triple, Non-metal, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (6B, 3B, 2A, 4C, 6A, 1A, 3C, 5C, 4B, 1B, 7, 1C, 2B, 5B, 4A, 5A, 2C, 3A, 6C, 8)
  • Exceeds IECC 2012 (8, 6B, 4A, 5B, 5A, 4C, 6A, 6C, 4B, 5C, 7)
  • Exceeds Energy Star 2010 (South-Central, North-Central, Southern, Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window31 - 6247

Add Storm Sash:

Before-Component After-Component Cost

Clear, Single, Metal

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.76
  • Storm Sash:
  • U-Value: 1.16 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Single-Pane, Clear, Metal Frame, with Clear Storm

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.676
  • Storm Sash: clear
  • U-Value: 0.781 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window7.2 - 1411

Add Window Film:

Before-Component After-Component Cost

Clear, Single, Metal

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.76
  • Storm Sash:
  • U-Value: 1.16 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Single-Pane, Clear, Metal Frame, with High-Tvis Film

Properties:

  • Film: high t-vis
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.43
  • Storm Sash:
  • U-Value: 1.09 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window5.7 - 108.1

Add Storm Sash:

Before-Component After-Component Cost

Clear, Single, Metal

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.76
  • Storm Sash:
  • U-Value: 1.16 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Single-Pane, Clear, Metal Frame, with Low-E Storm

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.586
  • Storm Sash: low-e
  • U-Value: 0.693 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window13 - 2319

Add Window Film:

Before-Component After-Component Cost

Clear, Single, Metal

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.76
  • Storm Sash:
  • U-Value: 1.16 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Single-Pane, Clear, Metal Frame, with Low-Tvis Film

Properties:

  • Film: low t-vis
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.37
  • Storm Sash:
  • U-Value: 1.14 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window2.1 - 3.93.1

Replace Window:

Before-Component After-Component Cost

Clear, Single, Non-metal

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.63
  • Storm Sash:
  • U-Value: 0.84 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Clear, Double, Metal, Air

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • Storm Sash:
  • U-Value: 0.76 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window21 - 4233

Replace Window:

Before-Component After-Component Cost

Clear, Single, Non-metal

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.63
  • Storm Sash:
  • U-Value: 0.84 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Clear, Double, Non-metal, Air

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.49 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window21 - 4333

Replace Window:

Before-Component After-Component Cost

Clear, Single, Non-metal

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.63
  • Storm Sash:
  • U-Value: 0.84 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Clear, Double, Thermal-Break, Air

Properties:

  • Film:
  • Frame Material: metal with thermal breaks
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.62
  • Storm Sash:
  • U-Value: 0.63 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window21 - 4233

Replace Window:

Before-Component After-Component Cost

Clear, Single, Non-metal

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.63
  • Storm Sash:
  • U-Value: 0.84 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Air, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.32 Btu/h-ft^2-R

Performance Standards:

  • Meets IECC 2012 (5C, 6B, 7, 5B, 5A, 4C, 6A, 6C, 8)
  • Exceeds IECC 2009 (5C, 4B, 7, 5B, 4A, 5A, 4C, 6A, 6C, 8, 6B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window28 - 5744

Replace Window:

Before-Component After-Component Cost

Clear, Single, Non-metal

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.63
  • Storm Sash:
  • U-Value: 0.84 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Air, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (8, 6B, 7, 6A, 6C, 5A, 4C, 4A, 5B, 4B, 5C)
  • Exceeds IECC 2009 (8, 6B, 7, 6A, 6C, 5A, 4C, 5B, 4A, 5C, 4B)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window30 - 6046

Replace Window:

Before-Component After-Component Cost

Clear, Single, Non-metal

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.63
  • Storm Sash:
  • U-Value: 0.84 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Air, M-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (5B, 5C, 8, 6B, 7, 6A, 6C, 5A, 4C)
  • Exceeds IECC 2009 (8, 6B, 7, 6A, 6C, 5A, 4C, 5B, 4A, 5C, 4B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window29 - 5845

Replace Window:

Before-Component After-Component Cost

Clear, Single, Non-metal

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.63
  • Storm Sash:
  • U-Value: 0.84 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (5C, 4B, 7, 5B, 4A, 5A, 4C, 6A, 6C, 8, 6B)
  • Exceeds IECC 2012 (5C, 6B, 7, 5B, 5A, 4C, 6A, 6C, 8)
  • Exceeds Energy Star 2010 (Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window30 - 6046

Replace Window:

Before-Component After-Component Cost

Clear, Single, Non-metal

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.63
  • Storm Sash:
  • U-Value: 0.84 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.26 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2009 (6A, 4C, 5B, 4A, 5C, 8, 4B, 6B, 7, 6C, 5A)
  • Exceeds IECC 2012 (6A, 4C, 4A, 5B, 4B, 5C, 8, 6B, 7, 6C, 5A)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window32 - 6349

Replace Window:

Before-Component After-Component Cost

Clear, Single, Non-metal

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.63
  • Storm Sash:
  • U-Value: 0.84 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Arg, M-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (4C, 6A, 6C, 5C, 8, 6B, 7, 5B, 5A)
  • Exceeds IECC 2009 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)
  • Exceeds Energy Star 2010 (Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window31 - 6248

Replace Window:

Before-Component After-Component Cost

Clear, Single, Non-metal

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.63
  • Storm Sash:
  • U-Value: 0.84 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Non-metal, Air, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.39 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window21 - 4434

Replace Window:

Before-Component After-Component Cost

Clear, Single, Non-metal

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.63
  • Storm Sash:
  • U-Value: 0.84 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Non-metal, Air, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (3B, 2C, 3A, 1B, 1A, 3C, 2B, 1C, 2A)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window23 - 4736

Replace Window:

Before-Component After-Component Cost

Clear, Single, Non-metal

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.63
  • Storm Sash:
  • U-Value: 0.84 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Non-metal, Air, M-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.38 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window22 - 4535

Replace Window:

Before-Component After-Component Cost

Clear, Single, Non-metal

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.63
  • Storm Sash:
  • U-Value: 0.84 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Non-metal, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window23 - 4736

Replace Window:

Before-Component After-Component Cost

Clear, Single, Non-metal

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.63
  • Storm Sash:
  • U-Value: 0.84 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Non-metal, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.34 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (South-Central)
  • Exceeds IECC 2012 (4A, 4B)
  • Exceeds IECC 2009 (8, 6A, 4C, 2A, 3B, 5B, 4A, 2B, 1C, 7, 1B, 5C, 4B, 1A, 3C, 6C, 2C, 3A, 5A, 6B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window25 - 5039

Replace Window:

Before-Component After-Component Cost

Clear, Single, Non-metal

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.63
  • Storm Sash:
  • U-Value: 0.84 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Non-metal, Arg, M-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.35 Btu/h-ft^2-R

Performance Standards:

  • Meets IECC 2009 (5C, 4B, 7, 5B, 4A, 5A, 4C, 6A, 6C, 8, 6B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window24 - 4938

Replace Window:

Before-Component After-Component Cost

Clear, Single, Non-metal

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.63
  • Storm Sash:
  • U-Value: 0.84 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Air, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.21 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2009 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)
  • Exceeds IECC 2012 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window36 - 7255

Replace Window:

Before-Component After-Component Cost

Clear, Single, Non-metal

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.63
  • Storm Sash:
  • U-Value: 0.84 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Air, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.19 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (North-Central, Southern, Northern, South-Central)
  • Exceeds IECC 2009 (6B, 6A, 3B, 2A, 4C, 1C, 2B, 5B, 4A, 1A, 3C, 5C, 4B, 1B, 7, 2C, 3A, 6C, 5A, 8)
  • Exceeds IECC 2012 (8, 6B, 7, 6A, 6C, 5A, 4C, 4A, 5B, 4B, 5C)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window37 - 7256

Replace Window:

Before-Component After-Component Cost

Clear, Single, Non-metal

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.63
  • Storm Sash:
  • U-Value: 0.84 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.18 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (8, 6B, 5B, 4A, 5A, 4C, 6A, 6C, 5C, 4B, 7)
  • Exceeds IECC 2009 (8, 6B, 5B, 4A, 5A, 4C, 6A, 6C, 5C, 4B, 7)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window38 - 7457

Replace Window:

Before-Component After-Component Cost

Clear, Single, Non-metal

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.63
  • Storm Sash:
  • U-Value: 0.84 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.17 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (Northern, North-Central, Southern, South-Central)
  • Exceeds IECC 2009 (6C, 5A, 2B, 5B, 4A, 1C, 1B, 7, 1A, 3C, 5C, 4B, 6A, 2A, 4C, 3B, 6B, 8, 2C, 3A)
  • Exceeds IECC 2012 (6C, 5A, 4A, 5B, 6B, 7, 4B, 5C, 8, 6A, 4C)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window38 - 7557

Replace Window:

Before-Component After-Component Cost

Clear, Single, Non-metal

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.63
  • Storm Sash:
  • U-Value: 0.84 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Triple, Non-metal, Air, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (4C, 6A, 6C, 4B, 5C, 8, 6B, 7, 4A, 5B, 5A)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2009 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)
  • Exceeds Energy Star 2010 (North-Central)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window29 - 5945

Replace Window:

Before-Component After-Component Cost

Clear, Single, Non-metal

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.63
  • Storm Sash:
  • U-Value: 0.84 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Triple, Non-metal, Air, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (South-Central, North-Central, Southern, Northern)
  • Exceeds IECC 2012 (4B, 5C, 7, 4A, 5B, 5A, 4C, 6A, 6C, 8, 6B)
  • Exceeds IECC 2009 (1A, 3C, 7, 4A, 5A, 2C, 3A, 6C, 8, 6B, 3B, 2A, 4C, 6A, 5C, 4B, 1B, 1C, 2B, 5B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window30 - 6046

Replace Window:

Before-Component After-Component Cost

Clear, Single, Non-metal

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.63
  • Storm Sash:
  • U-Value: 0.84 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Triple, Non-metal, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (5B, 4A, 5C, 4B, 6B, 7, 6A, 6C, 5A, 4C, 8)
  • Exceeds IECC 2012 (4A, 5B, 4B, 5C, 6B, 7, 6A, 6C, 5A, 4C, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window31 - 6147

Replace Window:

Before-Component After-Component Cost

Clear, Single, Non-metal

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.63
  • Storm Sash:
  • U-Value: 0.84 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Triple, Non-metal, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (6B, 3B, 2A, 4C, 6A, 1A, 3C, 5C, 4B, 1B, 7, 1C, 2B, 5B, 4A, 5A, 2C, 3A, 6C, 8)
  • Exceeds IECC 2012 (8, 6B, 4A, 5B, 5A, 4C, 6A, 6C, 4B, 5C, 7)
  • Exceeds Energy Star 2010 (South-Central, North-Central, Southern, Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window31 - 6247

Add Storm Sash:

Before-Component After-Component Cost

Clear, Single, Non-metal

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.63
  • Storm Sash:
  • U-Value: 0.84 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Single-Pane, Clear, Non-metal Frame, with Clear Storm

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.555
  • Storm Sash: clear
  • U-Value: 0.482 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window7.2 - 1411

Add Window Film:

Before-Component After-Component Cost

Clear, Single, Non-metal

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.63
  • Storm Sash:
  • U-Value: 0.84 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Single-Pane, Clear, Non-metal Frame, with High-Tvis Film

Properties:

  • Film: high t-vis
  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.35
  • Storm Sash:
  • U-Value: 0.78 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window5.7 - 108.1

Add Storm Sash:

Before-Component After-Component Cost

Clear, Single, Non-metal

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.63
  • Storm Sash:
  • U-Value: 0.84 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Single-Pane, Clear, Non-metal Frame, with Low-E Storm

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.475
  • Storm Sash: low-e
  • U-Value: 0.395 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window13 - 2319

Add Window Film:

Before-Component After-Component Cost

Clear, Single, Non-metal

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.63
  • Storm Sash:
  • U-Value: 0.84 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Single-Pane, Clear, Non-metal Frame, with Low-Tvis Film

Properties:

  • Film: low t-vis
  • Frame Material: non-metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.82 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window2.1 - 3.93.1

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Insulated, Air, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.32 Btu/h-ft^2-R

Performance Standards:

  • Meets IECC 2012 (5C, 6B, 7, 5B, 5A, 4C, 6A, 6C, 8)
  • Exceeds IECC 2009 (5C, 4B, 7, 5B, 4A, 5A, 4C, 6A, 6C, 8, 6B)

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Air, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.32 Btu/h-ft^2-R

Performance Standards:

  • Meets IECC 2012 (5C, 6B, 7, 5B, 5A, 4C, 6A, 6C, 8)
  • Exceeds IECC 2009 (5C, 4B, 7, 5B, 4A, 5A, 4C, 6A, 6C, 8, 6B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window28 - 5744

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Insulated, Air, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.32 Btu/h-ft^2-R

Performance Standards:

  • Meets IECC 2012 (5C, 6B, 7, 5B, 5A, 4C, 6A, 6C, 8)
  • Exceeds IECC 2009 (5C, 4B, 7, 5B, 4A, 5A, 4C, 6A, 6C, 8, 6B)

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Air, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (8, 6B, 7, 6A, 6C, 5A, 4C, 4A, 5B, 4B, 5C)
  • Exceeds IECC 2009 (8, 6B, 7, 6A, 6C, 5A, 4C, 5B, 4A, 5C, 4B)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window30 - 6046

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Insulated, Air, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.32 Btu/h-ft^2-R

Performance Standards:

  • Meets IECC 2012 (5C, 6B, 7, 5B, 5A, 4C, 6A, 6C, 8)
  • Exceeds IECC 2009 (5C, 4B, 7, 5B, 4A, 5A, 4C, 6A, 6C, 8, 6B)

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Air, M-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (5B, 5C, 8, 6B, 7, 6A, 6C, 5A, 4C)
  • Exceeds IECC 2009 (8, 6B, 7, 6A, 6C, 5A, 4C, 5B, 4A, 5C, 4B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window29 - 5845

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Insulated, Air, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.32 Btu/h-ft^2-R

Performance Standards:

  • Meets IECC 2012 (5C, 6B, 7, 5B, 5A, 4C, 6A, 6C, 8)
  • Exceeds IECC 2009 (5C, 4B, 7, 5B, 4A, 5A, 4C, 6A, 6C, 8, 6B)

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (5C, 4B, 7, 5B, 4A, 5A, 4C, 6A, 6C, 8, 6B)
  • Exceeds IECC 2012 (5C, 6B, 7, 5B, 5A, 4C, 6A, 6C, 8)
  • Exceeds Energy Star 2010 (Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window30 - 6046

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Insulated, Air, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.32 Btu/h-ft^2-R

Performance Standards:

  • Meets IECC 2012 (5C, 6B, 7, 5B, 5A, 4C, 6A, 6C, 8)
  • Exceeds IECC 2009 (5C, 4B, 7, 5B, 4A, 5A, 4C, 6A, 6C, 8, 6B)

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.26 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2009 (6A, 4C, 5B, 4A, 5C, 8, 4B, 6B, 7, 6C, 5A)
  • Exceeds IECC 2012 (6A, 4C, 4A, 5B, 4B, 5C, 8, 6B, 7, 6C, 5A)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window32 - 6349

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Insulated, Air, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.32 Btu/h-ft^2-R

Performance Standards:

  • Meets IECC 2012 (5C, 6B, 7, 5B, 5A, 4C, 6A, 6C, 8)
  • Exceeds IECC 2009 (5C, 4B, 7, 5B, 4A, 5A, 4C, 6A, 6C, 8, 6B)

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Arg, M-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (4C, 6A, 6C, 5C, 8, 6B, 7, 5B, 5A)
  • Exceeds IECC 2009 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)
  • Exceeds Energy Star 2010 (Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window31 - 6248

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Insulated, Air, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.32 Btu/h-ft^2-R

Performance Standards:

  • Meets IECC 2012 (5C, 6B, 7, 5B, 5A, 4C, 6A, 6C, 8)
  • Exceeds IECC 2009 (5C, 4B, 7, 5B, 4A, 5A, 4C, 6A, 6C, 8, 6B)

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Air, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.21 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2009 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)
  • Exceeds IECC 2012 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window36 - 7255

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Insulated, Air, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.32 Btu/h-ft^2-R

Performance Standards:

  • Meets IECC 2012 (5C, 6B, 7, 5B, 5A, 4C, 6A, 6C, 8)
  • Exceeds IECC 2009 (5C, 4B, 7, 5B, 4A, 5A, 4C, 6A, 6C, 8, 6B)

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Air, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.19 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (North-Central, Southern, Northern, South-Central)
  • Exceeds IECC 2009 (6B, 6A, 3B, 2A, 4C, 1C, 2B, 5B, 4A, 1A, 3C, 5C, 4B, 1B, 7, 2C, 3A, 6C, 5A, 8)
  • Exceeds IECC 2012 (8, 6B, 7, 6A, 6C, 5A, 4C, 4A, 5B, 4B, 5C)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window37 - 7256

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Insulated, Air, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.32 Btu/h-ft^2-R

Performance Standards:

  • Meets IECC 2012 (5C, 6B, 7, 5B, 5A, 4C, 6A, 6C, 8)
  • Exceeds IECC 2009 (5C, 4B, 7, 5B, 4A, 5A, 4C, 6A, 6C, 8, 6B)

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.18 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (8, 6B, 5B, 4A, 5A, 4C, 6A, 6C, 5C, 4B, 7)
  • Exceeds IECC 2009 (8, 6B, 5B, 4A, 5A, 4C, 6A, 6C, 5C, 4B, 7)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window38 - 7457

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Insulated, Air, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.32 Btu/h-ft^2-R

Performance Standards:

  • Meets IECC 2012 (5C, 6B, 7, 5B, 5A, 4C, 6A, 6C, 8)
  • Exceeds IECC 2009 (5C, 4B, 7, 5B, 4A, 5A, 4C, 6A, 6C, 8, 6B)

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.17 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (Northern, North-Central, Southern, South-Central)
  • Exceeds IECC 2009 (6C, 5A, 2B, 5B, 4A, 1C, 1B, 7, 1A, 3C, 5C, 4B, 6A, 2A, 4C, 3B, 6B, 8, 2C, 3A)
  • Exceeds IECC 2012 (6C, 5A, 4A, 5B, 6B, 7, 4B, 5C, 8, 6A, 4C)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window38 - 7557

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Insulated, Air, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.32 Btu/h-ft^2-R

Performance Standards:

  • Meets IECC 2012 (5C, 6B, 7, 5B, 5A, 4C, 6A, 6C, 8)
  • Exceeds IECC 2009 (5C, 4B, 7, 5B, 4A, 5A, 4C, 6A, 6C, 8, 6B)

Lifetime:

  • 30 Years
 

Low-E, Triple, Non-metal, Air, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (4C, 6A, 6C, 4B, 5C, 8, 6B, 7, 4A, 5B, 5A)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2009 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)
  • Exceeds Energy Star 2010 (North-Central)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window29 - 5945

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Insulated, Air, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.32 Btu/h-ft^2-R

Performance Standards:

  • Meets IECC 2012 (5C, 6B, 7, 5B, 5A, 4C, 6A, 6C, 8)
  • Exceeds IECC 2009 (5C, 4B, 7, 5B, 4A, 5A, 4C, 6A, 6C, 8, 6B)

Lifetime:

  • 30 Years
 

Low-E, Triple, Non-metal, Air, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (South-Central, North-Central, Southern, Northern)
  • Exceeds IECC 2012 (4B, 5C, 7, 4A, 5B, 5A, 4C, 6A, 6C, 8, 6B)
  • Exceeds IECC 2009 (1A, 3C, 7, 4A, 5A, 2C, 3A, 6C, 8, 6B, 3B, 2A, 4C, 6A, 5C, 4B, 1B, 1C, 2B, 5B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window30 - 6046

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Insulated, Air, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.32 Btu/h-ft^2-R

Performance Standards:

  • Meets IECC 2012 (5C, 6B, 7, 5B, 5A, 4C, 6A, 6C, 8)
  • Exceeds IECC 2009 (5C, 4B, 7, 5B, 4A, 5A, 4C, 6A, 6C, 8, 6B)

Lifetime:

  • 30 Years
 

Low-E, Triple, Non-metal, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (5B, 4A, 5C, 4B, 6B, 7, 6A, 6C, 5A, 4C, 8)
  • Exceeds IECC 2012 (4A, 5B, 4B, 5C, 6B, 7, 6A, 6C, 5A, 4C, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window31 - 6147

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Insulated, Air, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.32 Btu/h-ft^2-R

Performance Standards:

  • Meets IECC 2012 (5C, 6B, 7, 5B, 5A, 4C, 6A, 6C, 8)
  • Exceeds IECC 2009 (5C, 4B, 7, 5B, 4A, 5A, 4C, 6A, 6C, 8, 6B)

Lifetime:

  • 30 Years
 

Low-E, Triple, Non-metal, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (6B, 3B, 2A, 4C, 6A, 1A, 3C, 5C, 4B, 1B, 7, 1C, 2B, 5B, 4A, 5A, 2C, 3A, 6C, 8)
  • Exceeds IECC 2012 (8, 6B, 4A, 5B, 5A, 4C, 6A, 6C, 4B, 5C, 7)
  • Exceeds Energy Star 2010 (South-Central, North-Central, Southern, Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window31 - 6247

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Insulated, Air, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (8, 6B, 7, 6A, 6C, 5A, 4C, 4A, 5B, 4B, 5C)
  • Exceeds IECC 2009 (8, 6B, 7, 6A, 6C, 5A, 4C, 5B, 4A, 5C, 4B)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Air, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (8, 6B, 7, 6A, 6C, 5A, 4C, 4A, 5B, 4B, 5C)
  • Exceeds IECC 2009 (8, 6B, 7, 6A, 6C, 5A, 4C, 5B, 4A, 5C, 4B)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window30 - 6046

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Insulated, Air, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (8, 6B, 7, 6A, 6C, 5A, 4C, 4A, 5B, 4B, 5C)
  • Exceeds IECC 2009 (8, 6B, 7, 6A, 6C, 5A, 4C, 5B, 4A, 5C, 4B)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (5C, 4B, 7, 5B, 4A, 5A, 4C, 6A, 6C, 8, 6B)
  • Exceeds IECC 2012 (5C, 6B, 7, 5B, 5A, 4C, 6A, 6C, 8)
  • Exceeds Energy Star 2010 (Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window30 - 6046

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Insulated, Air, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (8, 6B, 7, 6A, 6C, 5A, 4C, 4A, 5B, 4B, 5C)
  • Exceeds IECC 2009 (8, 6B, 7, 6A, 6C, 5A, 4C, 5B, 4A, 5C, 4B)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.26 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2009 (6A, 4C, 5B, 4A, 5C, 8, 4B, 6B, 7, 6C, 5A)
  • Exceeds IECC 2012 (6A, 4C, 4A, 5B, 4B, 5C, 8, 6B, 7, 6C, 5A)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window32 - 6349

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Insulated, Air, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (8, 6B, 7, 6A, 6C, 5A, 4C, 4A, 5B, 4B, 5C)
  • Exceeds IECC 2009 (8, 6B, 7, 6A, 6C, 5A, 4C, 5B, 4A, 5C, 4B)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Arg, M-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (4C, 6A, 6C, 5C, 8, 6B, 7, 5B, 5A)
  • Exceeds IECC 2009 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)
  • Exceeds Energy Star 2010 (Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window31 - 6248

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Insulated, Air, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (8, 6B, 7, 6A, 6C, 5A, 4C, 4A, 5B, 4B, 5C)
  • Exceeds IECC 2009 (8, 6B, 7, 6A, 6C, 5A, 4C, 5B, 4A, 5C, 4B)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Air, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.21 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2009 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)
  • Exceeds IECC 2012 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window36 - 7255

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Insulated, Air, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (8, 6B, 7, 6A, 6C, 5A, 4C, 4A, 5B, 4B, 5C)
  • Exceeds IECC 2009 (8, 6B, 7, 6A, 6C, 5A, 4C, 5B, 4A, 5C, 4B)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Air, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.19 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (North-Central, Southern, Northern, South-Central)
  • Exceeds IECC 2009 (6B, 6A, 3B, 2A, 4C, 1C, 2B, 5B, 4A, 1A, 3C, 5C, 4B, 1B, 7, 2C, 3A, 6C, 5A, 8)
  • Exceeds IECC 2012 (8, 6B, 7, 6A, 6C, 5A, 4C, 4A, 5B, 4B, 5C)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window37 - 7256

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Insulated, Air, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (8, 6B, 7, 6A, 6C, 5A, 4C, 4A, 5B, 4B, 5C)
  • Exceeds IECC 2009 (8, 6B, 7, 6A, 6C, 5A, 4C, 5B, 4A, 5C, 4B)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.18 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (8, 6B, 5B, 4A, 5A, 4C, 6A, 6C, 5C, 4B, 7)
  • Exceeds IECC 2009 (8, 6B, 5B, 4A, 5A, 4C, 6A, 6C, 5C, 4B, 7)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window38 - 7457

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Insulated, Air, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (8, 6B, 7, 6A, 6C, 5A, 4C, 4A, 5B, 4B, 5C)
  • Exceeds IECC 2009 (8, 6B, 7, 6A, 6C, 5A, 4C, 5B, 4A, 5C, 4B)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.17 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (Northern, North-Central, Southern, South-Central)
  • Exceeds IECC 2009 (6C, 5A, 2B, 5B, 4A, 1C, 1B, 7, 1A, 3C, 5C, 4B, 6A, 2A, 4C, 3B, 6B, 8, 2C, 3A)
  • Exceeds IECC 2012 (6C, 5A, 4A, 5B, 6B, 7, 4B, 5C, 8, 6A, 4C)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window38 - 7557

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Insulated, Air, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (8, 6B, 7, 6A, 6C, 5A, 4C, 4A, 5B, 4B, 5C)
  • Exceeds IECC 2009 (8, 6B, 7, 6A, 6C, 5A, 4C, 5B, 4A, 5C, 4B)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Low-E, Triple, Non-metal, Air, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (South-Central, North-Central, Southern, Northern)
  • Exceeds IECC 2012 (4B, 5C, 7, 4A, 5B, 5A, 4C, 6A, 6C, 8, 6B)
  • Exceeds IECC 2009 (1A, 3C, 7, 4A, 5A, 2C, 3A, 6C, 8, 6B, 3B, 2A, 4C, 6A, 5C, 4B, 1B, 1C, 2B, 5B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window30 - 6046

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Insulated, Air, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (8, 6B, 7, 6A, 6C, 5A, 4C, 4A, 5B, 4B, 5C)
  • Exceeds IECC 2009 (8, 6B, 7, 6A, 6C, 5A, 4C, 5B, 4A, 5C, 4B)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Low-E, Triple, Non-metal, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (5B, 4A, 5C, 4B, 6B, 7, 6A, 6C, 5A, 4C, 8)
  • Exceeds IECC 2012 (4A, 5B, 4B, 5C, 6B, 7, 6A, 6C, 5A, 4C, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window31 - 6147

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Insulated, Air, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (8, 6B, 7, 6A, 6C, 5A, 4C, 4A, 5B, 4B, 5C)
  • Exceeds IECC 2009 (8, 6B, 7, 6A, 6C, 5A, 4C, 5B, 4A, 5C, 4B)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Low-E, Triple, Non-metal, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (6B, 3B, 2A, 4C, 6A, 1A, 3C, 5C, 4B, 1B, 7, 1C, 2B, 5B, 4A, 5A, 2C, 3A, 6C, 8)
  • Exceeds IECC 2012 (8, 6B, 4A, 5B, 5A, 4C, 6A, 6C, 4B, 5C, 7)
  • Exceeds Energy Star 2010 (South-Central, North-Central, Southern, Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window31 - 6247

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Insulated, Air, M-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (5B, 5C, 8, 6B, 7, 6A, 6C, 5A, 4C)
  • Exceeds IECC 2009 (8, 6B, 7, 6A, 6C, 5A, 4C, 5B, 4A, 5C, 4B)

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Air, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (8, 6B, 7, 6A, 6C, 5A, 4C, 4A, 5B, 4B, 5C)
  • Exceeds IECC 2009 (8, 6B, 7, 6A, 6C, 5A, 4C, 5B, 4A, 5C, 4B)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window30 - 6046

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Insulated, Air, M-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (5B, 5C, 8, 6B, 7, 6A, 6C, 5A, 4C)
  • Exceeds IECC 2009 (8, 6B, 7, 6A, 6C, 5A, 4C, 5B, 4A, 5C, 4B)

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Air, M-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (5B, 5C, 8, 6B, 7, 6A, 6C, 5A, 4C)
  • Exceeds IECC 2009 (8, 6B, 7, 6A, 6C, 5A, 4C, 5B, 4A, 5C, 4B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window29 - 5845

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Insulated, Air, M-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (5B, 5C, 8, 6B, 7, 6A, 6C, 5A, 4C)
  • Exceeds IECC 2009 (8, 6B, 7, 6A, 6C, 5A, 4C, 5B, 4A, 5C, 4B)

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (5C, 4B, 7, 5B, 4A, 5A, 4C, 6A, 6C, 8, 6B)
  • Exceeds IECC 2012 (5C, 6B, 7, 5B, 5A, 4C, 6A, 6C, 8)
  • Exceeds Energy Star 2010 (Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window30 - 6046

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Insulated, Air, M-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (5B, 5C, 8, 6B, 7, 6A, 6C, 5A, 4C)
  • Exceeds IECC 2009 (8, 6B, 7, 6A, 6C, 5A, 4C, 5B, 4A, 5C, 4B)

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.26 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2009 (6A, 4C, 5B, 4A, 5C, 8, 4B, 6B, 7, 6C, 5A)
  • Exceeds IECC 2012 (6A, 4C, 4A, 5B, 4B, 5C, 8, 6B, 7, 6C, 5A)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window32 - 6349

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Insulated, Air, M-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (5B, 5C, 8, 6B, 7, 6A, 6C, 5A, 4C)
  • Exceeds IECC 2009 (8, 6B, 7, 6A, 6C, 5A, 4C, 5B, 4A, 5C, 4B)

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Arg, M-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (4C, 6A, 6C, 5C, 8, 6B, 7, 5B, 5A)
  • Exceeds IECC 2009 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)
  • Exceeds Energy Star 2010 (Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window31 - 6248

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Insulated, Air, M-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (5B, 5C, 8, 6B, 7, 6A, 6C, 5A, 4C)
  • Exceeds IECC 2009 (8, 6B, 7, 6A, 6C, 5A, 4C, 5B, 4A, 5C, 4B)

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Air, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.21 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2009 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)
  • Exceeds IECC 2012 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window36 - 7255

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Insulated, Air, M-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (5B, 5C, 8, 6B, 7, 6A, 6C, 5A, 4C)
  • Exceeds IECC 2009 (8, 6B, 7, 6A, 6C, 5A, 4C, 5B, 4A, 5C, 4B)

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Air, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.19 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (North-Central, Southern, Northern, South-Central)
  • Exceeds IECC 2009 (6B, 6A, 3B, 2A, 4C, 1C, 2B, 5B, 4A, 1A, 3C, 5C, 4B, 1B, 7, 2C, 3A, 6C, 5A, 8)
  • Exceeds IECC 2012 (8, 6B, 7, 6A, 6C, 5A, 4C, 4A, 5B, 4B, 5C)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window37 - 7256

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Insulated, Air, M-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (5B, 5C, 8, 6B, 7, 6A, 6C, 5A, 4C)
  • Exceeds IECC 2009 (8, 6B, 7, 6A, 6C, 5A, 4C, 5B, 4A, 5C, 4B)

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.18 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (8, 6B, 5B, 4A, 5A, 4C, 6A, 6C, 5C, 4B, 7)
  • Exceeds IECC 2009 (8, 6B, 5B, 4A, 5A, 4C, 6A, 6C, 5C, 4B, 7)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window38 - 7457

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Insulated, Air, M-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (5B, 5C, 8, 6B, 7, 6A, 6C, 5A, 4C)
  • Exceeds IECC 2009 (8, 6B, 7, 6A, 6C, 5A, 4C, 5B, 4A, 5C, 4B)

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.17 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (Northern, North-Central, Southern, South-Central)
  • Exceeds IECC 2009 (6C, 5A, 2B, 5B, 4A, 1C, 1B, 7, 1A, 3C, 5C, 4B, 6A, 2A, 4C, 3B, 6B, 8, 2C, 3A)
  • Exceeds IECC 2012 (6C, 5A, 4A, 5B, 6B, 7, 4B, 5C, 8, 6A, 4C)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window38 - 7557

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Insulated, Air, M-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (5B, 5C, 8, 6B, 7, 6A, 6C, 5A, 4C)
  • Exceeds IECC 2009 (8, 6B, 7, 6A, 6C, 5A, 4C, 5B, 4A, 5C, 4B)

Lifetime:

  • 30 Years
 

Low-E, Triple, Non-metal, Air, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (4C, 6A, 6C, 4B, 5C, 8, 6B, 7, 4A, 5B, 5A)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2009 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)
  • Exceeds Energy Star 2010 (North-Central)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window29 - 5945

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Insulated, Air, M-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (5B, 5C, 8, 6B, 7, 6A, 6C, 5A, 4C)
  • Exceeds IECC 2009 (8, 6B, 7, 6A, 6C, 5A, 4C, 5B, 4A, 5C, 4B)

Lifetime:

  • 30 Years
 

Low-E, Triple, Non-metal, Air, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (South-Central, North-Central, Southern, Northern)
  • Exceeds IECC 2012 (4B, 5C, 7, 4A, 5B, 5A, 4C, 6A, 6C, 8, 6B)
  • Exceeds IECC 2009 (1A, 3C, 7, 4A, 5A, 2C, 3A, 6C, 8, 6B, 3B, 2A, 4C, 6A, 5C, 4B, 1B, 1C, 2B, 5B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window30 - 6046

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Insulated, Air, M-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (5B, 5C, 8, 6B, 7, 6A, 6C, 5A, 4C)
  • Exceeds IECC 2009 (8, 6B, 7, 6A, 6C, 5A, 4C, 5B, 4A, 5C, 4B)

Lifetime:

  • 30 Years
 

Low-E, Triple, Non-metal, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (5B, 4A, 5C, 4B, 6B, 7, 6A, 6C, 5A, 4C, 8)
  • Exceeds IECC 2012 (4A, 5B, 4B, 5C, 6B, 7, 6A, 6C, 5A, 4C, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window31 - 6147

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Insulated, Air, M-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (5B, 5C, 8, 6B, 7, 6A, 6C, 5A, 4C)
  • Exceeds IECC 2009 (8, 6B, 7, 6A, 6C, 5A, 4C, 5B, 4A, 5C, 4B)

Lifetime:

  • 30 Years
 

Low-E, Triple, Non-metal, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (6B, 3B, 2A, 4C, 6A, 1A, 3C, 5C, 4B, 1B, 7, 1C, 2B, 5B, 4A, 5A, 2C, 3A, 6C, 8)
  • Exceeds IECC 2012 (8, 6B, 4A, 5B, 5A, 4C, 6A, 6C, 4B, 5C, 7)
  • Exceeds Energy Star 2010 (South-Central, North-Central, Southern, Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window31 - 6247

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Insulated, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (5C, 4B, 7, 5B, 4A, 5A, 4C, 6A, 6C, 8, 6B)
  • Exceeds IECC 2012 (5C, 6B, 7, 5B, 5A, 4C, 6A, 6C, 8)
  • Exceeds Energy Star 2010 (Northern)

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Air, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (8, 6B, 7, 6A, 6C, 5A, 4C, 4A, 5B, 4B, 5C)
  • Exceeds IECC 2009 (8, 6B, 7, 6A, 6C, 5A, 4C, 5B, 4A, 5C, 4B)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window30 - 6046

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Insulated, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (5C, 4B, 7, 5B, 4A, 5A, 4C, 6A, 6C, 8, 6B)
  • Exceeds IECC 2012 (5C, 6B, 7, 5B, 5A, 4C, 6A, 6C, 8)
  • Exceeds Energy Star 2010 (Northern)

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (5C, 4B, 7, 5B, 4A, 5A, 4C, 6A, 6C, 8, 6B)
  • Exceeds IECC 2012 (5C, 6B, 7, 5B, 5A, 4C, 6A, 6C, 8)
  • Exceeds Energy Star 2010 (Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window30 - 6046

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Insulated, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (5C, 4B, 7, 5B, 4A, 5A, 4C, 6A, 6C, 8, 6B)
  • Exceeds IECC 2012 (5C, 6B, 7, 5B, 5A, 4C, 6A, 6C, 8)
  • Exceeds Energy Star 2010 (Northern)

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.26 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2009 (6A, 4C, 5B, 4A, 5C, 8, 4B, 6B, 7, 6C, 5A)
  • Exceeds IECC 2012 (6A, 4C, 4A, 5B, 4B, 5C, 8, 6B, 7, 6C, 5A)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window32 - 6349

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Insulated, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (5C, 4B, 7, 5B, 4A, 5A, 4C, 6A, 6C, 8, 6B)
  • Exceeds IECC 2012 (5C, 6B, 7, 5B, 5A, 4C, 6A, 6C, 8)
  • Exceeds Energy Star 2010 (Northern)

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Arg, M-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (4C, 6A, 6C, 5C, 8, 6B, 7, 5B, 5A)
  • Exceeds IECC 2009 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)
  • Exceeds Energy Star 2010 (Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window31 - 6248

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Insulated, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (5C, 4B, 7, 5B, 4A, 5A, 4C, 6A, 6C, 8, 6B)
  • Exceeds IECC 2012 (5C, 6B, 7, 5B, 5A, 4C, 6A, 6C, 8)
  • Exceeds Energy Star 2010 (Northern)

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Air, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.21 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2009 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)
  • Exceeds IECC 2012 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window36 - 7255

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Insulated, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (5C, 4B, 7, 5B, 4A, 5A, 4C, 6A, 6C, 8, 6B)
  • Exceeds IECC 2012 (5C, 6B, 7, 5B, 5A, 4C, 6A, 6C, 8)
  • Exceeds Energy Star 2010 (Northern)

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Air, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.19 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (North-Central, Southern, Northern, South-Central)
  • Exceeds IECC 2009 (6B, 6A, 3B, 2A, 4C, 1C, 2B, 5B, 4A, 1A, 3C, 5C, 4B, 1B, 7, 2C, 3A, 6C, 5A, 8)
  • Exceeds IECC 2012 (8, 6B, 7, 6A, 6C, 5A, 4C, 4A, 5B, 4B, 5C)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window37 - 7256

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Insulated, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (5C, 4B, 7, 5B, 4A, 5A, 4C, 6A, 6C, 8, 6B)
  • Exceeds IECC 2012 (5C, 6B, 7, 5B, 5A, 4C, 6A, 6C, 8)
  • Exceeds Energy Star 2010 (Northern)

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.18 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (8, 6B, 5B, 4A, 5A, 4C, 6A, 6C, 5C, 4B, 7)
  • Exceeds IECC 2009 (8, 6B, 5B, 4A, 5A, 4C, 6A, 6C, 5C, 4B, 7)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window38 - 7457

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Insulated, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (5C, 4B, 7, 5B, 4A, 5A, 4C, 6A, 6C, 8, 6B)
  • Exceeds IECC 2012 (5C, 6B, 7, 5B, 5A, 4C, 6A, 6C, 8)
  • Exceeds Energy Star 2010 (Northern)

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.17 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (Northern, North-Central, Southern, South-Central)
  • Exceeds IECC 2009 (6C, 5A, 2B, 5B, 4A, 1C, 1B, 7, 1A, 3C, 5C, 4B, 6A, 2A, 4C, 3B, 6B, 8, 2C, 3A)
  • Exceeds IECC 2012 (6C, 5A, 4A, 5B, 6B, 7, 4B, 5C, 8, 6A, 4C)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window38 - 7557

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Insulated, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (5C, 4B, 7, 5B, 4A, 5A, 4C, 6A, 6C, 8, 6B)
  • Exceeds IECC 2012 (5C, 6B, 7, 5B, 5A, 4C, 6A, 6C, 8)
  • Exceeds Energy Star 2010 (Northern)

Lifetime:

  • 30 Years
 

Low-E, Triple, Non-metal, Air, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (South-Central, North-Central, Southern, Northern)
  • Exceeds IECC 2012 (4B, 5C, 7, 4A, 5B, 5A, 4C, 6A, 6C, 8, 6B)
  • Exceeds IECC 2009 (1A, 3C, 7, 4A, 5A, 2C, 3A, 6C, 8, 6B, 3B, 2A, 4C, 6A, 5C, 4B, 1B, 1C, 2B, 5B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window30 - 6046

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Insulated, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (5C, 4B, 7, 5B, 4A, 5A, 4C, 6A, 6C, 8, 6B)
  • Exceeds IECC 2012 (5C, 6B, 7, 5B, 5A, 4C, 6A, 6C, 8)
  • Exceeds Energy Star 2010 (Northern)

Lifetime:

  • 30 Years
 

Low-E, Triple, Non-metal, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (5B, 4A, 5C, 4B, 6B, 7, 6A, 6C, 5A, 4C, 8)
  • Exceeds IECC 2012 (4A, 5B, 4B, 5C, 6B, 7, 6A, 6C, 5A, 4C, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window31 - 6147

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Insulated, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (5C, 4B, 7, 5B, 4A, 5A, 4C, 6A, 6C, 8, 6B)
  • Exceeds IECC 2012 (5C, 6B, 7, 5B, 5A, 4C, 6A, 6C, 8)
  • Exceeds Energy Star 2010 (Northern)

Lifetime:

  • 30 Years
 

Low-E, Triple, Non-metal, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (6B, 3B, 2A, 4C, 6A, 1A, 3C, 5C, 4B, 1B, 7, 1C, 2B, 5B, 4A, 5A, 2C, 3A, 6C, 8)
  • Exceeds IECC 2012 (8, 6B, 4A, 5B, 5A, 4C, 6A, 6C, 4B, 5C, 7)
  • Exceeds Energy Star 2010 (South-Central, North-Central, Southern, Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window31 - 6247

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Insulated, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.26 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2009 (6A, 4C, 5B, 4A, 5C, 8, 4B, 6B, 7, 6C, 5A)
  • Exceeds IECC 2012 (6A, 4C, 4A, 5B, 4B, 5C, 8, 6B, 7, 6C, 5A)

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.26 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2009 (6A, 4C, 5B, 4A, 5C, 8, 4B, 6B, 7, 6C, 5A)
  • Exceeds IECC 2012 (6A, 4C, 4A, 5B, 4B, 5C, 8, 6B, 7, 6C, 5A)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window32 - 6349

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Insulated, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.26 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2009 (6A, 4C, 5B, 4A, 5C, 8, 4B, 6B, 7, 6C, 5A)
  • Exceeds IECC 2012 (6A, 4C, 4A, 5B, 4B, 5C, 8, 6B, 7, 6C, 5A)

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Air, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.21 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2009 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)
  • Exceeds IECC 2012 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window36 - 7255

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Insulated, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.26 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2009 (6A, 4C, 5B, 4A, 5C, 8, 4B, 6B, 7, 6C, 5A)
  • Exceeds IECC 2012 (6A, 4C, 4A, 5B, 4B, 5C, 8, 6B, 7, 6C, 5A)

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Air, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.19 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (North-Central, Southern, Northern, South-Central)
  • Exceeds IECC 2009 (6B, 6A, 3B, 2A, 4C, 1C, 2B, 5B, 4A, 1A, 3C, 5C, 4B, 1B, 7, 2C, 3A, 6C, 5A, 8)
  • Exceeds IECC 2012 (8, 6B, 7, 6A, 6C, 5A, 4C, 4A, 5B, 4B, 5C)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window37 - 7256

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Insulated, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.26 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2009 (6A, 4C, 5B, 4A, 5C, 8, 4B, 6B, 7, 6C, 5A)
  • Exceeds IECC 2012 (6A, 4C, 4A, 5B, 4B, 5C, 8, 6B, 7, 6C, 5A)

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.18 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (8, 6B, 5B, 4A, 5A, 4C, 6A, 6C, 5C, 4B, 7)
  • Exceeds IECC 2009 (8, 6B, 5B, 4A, 5A, 4C, 6A, 6C, 5C, 4B, 7)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window38 - 7457

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Insulated, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.26 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2009 (6A, 4C, 5B, 4A, 5C, 8, 4B, 6B, 7, 6C, 5A)
  • Exceeds IECC 2012 (6A, 4C, 4A, 5B, 4B, 5C, 8, 6B, 7, 6C, 5A)

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.17 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (Northern, North-Central, Southern, South-Central)
  • Exceeds IECC 2009 (6C, 5A, 2B, 5B, 4A, 1C, 1B, 7, 1A, 3C, 5C, 4B, 6A, 2A, 4C, 3B, 6B, 8, 2C, 3A)
  • Exceeds IECC 2012 (6C, 5A, 4A, 5B, 6B, 7, 4B, 5C, 8, 6A, 4C)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window38 - 7557

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Insulated, Arg, M-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (4C, 6A, 6C, 5C, 8, 6B, 7, 5B, 5A)
  • Exceeds IECC 2009 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)
  • Exceeds Energy Star 2010 (Northern)

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.26 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2009 (6A, 4C, 5B, 4A, 5C, 8, 4B, 6B, 7, 6C, 5A)
  • Exceeds IECC 2012 (6A, 4C, 4A, 5B, 4B, 5C, 8, 6B, 7, 6C, 5A)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window32 - 6349

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Insulated, Arg, M-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (4C, 6A, 6C, 5C, 8, 6B, 7, 5B, 5A)
  • Exceeds IECC 2009 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)
  • Exceeds Energy Star 2010 (Northern)

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Arg, M-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (4C, 6A, 6C, 5C, 8, 6B, 7, 5B, 5A)
  • Exceeds IECC 2009 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)
  • Exceeds Energy Star 2010 (Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window31 - 6248

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Insulated, Arg, M-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (4C, 6A, 6C, 5C, 8, 6B, 7, 5B, 5A)
  • Exceeds IECC 2009 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)
  • Exceeds Energy Star 2010 (Northern)

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Air, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.21 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2009 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)
  • Exceeds IECC 2012 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window36 - 7255

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Insulated, Arg, M-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (4C, 6A, 6C, 5C, 8, 6B, 7, 5B, 5A)
  • Exceeds IECC 2009 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)
  • Exceeds Energy Star 2010 (Northern)

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Air, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.19 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (North-Central, Southern, Northern, South-Central)
  • Exceeds IECC 2009 (6B, 6A, 3B, 2A, 4C, 1C, 2B, 5B, 4A, 1A, 3C, 5C, 4B, 1B, 7, 2C, 3A, 6C, 5A, 8)
  • Exceeds IECC 2012 (8, 6B, 7, 6A, 6C, 5A, 4C, 4A, 5B, 4B, 5C)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window37 - 7256

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Insulated, Arg, M-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (4C, 6A, 6C, 5C, 8, 6B, 7, 5B, 5A)
  • Exceeds IECC 2009 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)
  • Exceeds Energy Star 2010 (Northern)

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.18 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (8, 6B, 5B, 4A, 5A, 4C, 6A, 6C, 5C, 4B, 7)
  • Exceeds IECC 2009 (8, 6B, 5B, 4A, 5A, 4C, 6A, 6C, 5C, 4B, 7)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window38 - 7457

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Insulated, Arg, M-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (4C, 6A, 6C, 5C, 8, 6B, 7, 5B, 5A)
  • Exceeds IECC 2009 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)
  • Exceeds Energy Star 2010 (Northern)

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.17 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (Northern, North-Central, Southern, South-Central)
  • Exceeds IECC 2009 (6C, 5A, 2B, 5B, 4A, 1C, 1B, 7, 1A, 3C, 5C, 4B, 6A, 2A, 4C, 3B, 6B, 8, 2C, 3A)
  • Exceeds IECC 2012 (6C, 5A, 4A, 5B, 6B, 7, 4B, 5C, 8, 6A, 4C)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window38 - 7557

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Insulated, Arg, M-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (4C, 6A, 6C, 5C, 8, 6B, 7, 5B, 5A)
  • Exceeds IECC 2009 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)
  • Exceeds Energy Star 2010 (Northern)

Lifetime:

  • 30 Years
 

Low-E, Triple, Non-metal, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (6B, 3B, 2A, 4C, 6A, 1A, 3C, 5C, 4B, 1B, 7, 1C, 2B, 5B, 4A, 5A, 2C, 3A, 6C, 8)
  • Exceeds IECC 2012 (8, 6B, 4A, 5B, 5A, 4C, 6A, 6C, 4B, 5C, 7)
  • Exceeds Energy Star 2010 (South-Central, North-Central, Southern, Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window31 - 6247

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Air, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.39 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Air, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.32 Btu/h-ft^2-R

Performance Standards:

  • Meets IECC 2012 (5C, 6B, 7, 5B, 5A, 4C, 6A, 6C, 8)
  • Exceeds IECC 2009 (5C, 4B, 7, 5B, 4A, 5A, 4C, 6A, 6C, 8, 6B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window28 - 5744

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Air, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.39 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Air, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (8, 6B, 7, 6A, 6C, 5A, 4C, 4A, 5B, 4B, 5C)
  • Exceeds IECC 2009 (8, 6B, 7, 6A, 6C, 5A, 4C, 5B, 4A, 5C, 4B)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window30 - 6046

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Air, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.39 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Air, M-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (5B, 5C, 8, 6B, 7, 6A, 6C, 5A, 4C)
  • Exceeds IECC 2009 (8, 6B, 7, 6A, 6C, 5A, 4C, 5B, 4A, 5C, 4B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window29 - 5845

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Air, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.39 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (5C, 4B, 7, 5B, 4A, 5A, 4C, 6A, 6C, 8, 6B)
  • Exceeds IECC 2012 (5C, 6B, 7, 5B, 5A, 4C, 6A, 6C, 8)
  • Exceeds Energy Star 2010 (Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window30 - 6046

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Air, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.39 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.26 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2009 (6A, 4C, 5B, 4A, 5C, 8, 4B, 6B, 7, 6C, 5A)
  • Exceeds IECC 2012 (6A, 4C, 4A, 5B, 4B, 5C, 8, 6B, 7, 6C, 5A)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window32 - 6349

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Air, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.39 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Arg, M-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (4C, 6A, 6C, 5C, 8, 6B, 7, 5B, 5A)
  • Exceeds IECC 2009 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)
  • Exceeds Energy Star 2010 (Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window31 - 6248

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Air, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.39 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Non-metal, Air, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.39 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window21 - 4434

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Air, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.39 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Non-metal, Air, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (3B, 2C, 3A, 1B, 1A, 3C, 2B, 1C, 2A)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window23 - 4736

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Air, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.39 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Non-metal, Air, M-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.38 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window22 - 4535

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Air, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.39 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Non-metal, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window23 - 4736

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Air, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.39 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Non-metal, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.34 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (South-Central)
  • Exceeds IECC 2012 (4A, 4B)
  • Exceeds IECC 2009 (8, 6A, 4C, 2A, 3B, 5B, 4A, 2B, 1C, 7, 1B, 5C, 4B, 1A, 3C, 6C, 2C, 3A, 5A, 6B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window25 - 5039

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Air, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.39 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Non-metal, Arg, M-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.35 Btu/h-ft^2-R

Performance Standards:

  • Meets IECC 2009 (5C, 4B, 7, 5B, 4A, 5A, 4C, 6A, 6C, 8, 6B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window24 - 4938

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Air, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.39 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Air, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.21 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2009 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)
  • Exceeds IECC 2012 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window36 - 7255

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Air, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.39 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Air, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.19 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (North-Central, Southern, Northern, South-Central)
  • Exceeds IECC 2009 (6B, 6A, 3B, 2A, 4C, 1C, 2B, 5B, 4A, 1A, 3C, 5C, 4B, 1B, 7, 2C, 3A, 6C, 5A, 8)
  • Exceeds IECC 2012 (8, 6B, 7, 6A, 6C, 5A, 4C, 4A, 5B, 4B, 5C)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window37 - 7256

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Air, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.39 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.18 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (8, 6B, 5B, 4A, 5A, 4C, 6A, 6C, 5C, 4B, 7)
  • Exceeds IECC 2009 (8, 6B, 5B, 4A, 5A, 4C, 6A, 6C, 5C, 4B, 7)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window38 - 7457

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Air, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.39 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.17 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (Northern, North-Central, Southern, South-Central)
  • Exceeds IECC 2009 (6C, 5A, 2B, 5B, 4A, 1C, 1B, 7, 1A, 3C, 5C, 4B, 6A, 2A, 4C, 3B, 6B, 8, 2C, 3A)
  • Exceeds IECC 2012 (6C, 5A, 4A, 5B, 6B, 7, 4B, 5C, 8, 6A, 4C)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window38 - 7557

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Air, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.39 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Triple, Non-metal, Air, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (4C, 6A, 6C, 4B, 5C, 8, 6B, 7, 4A, 5B, 5A)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2009 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)
  • Exceeds Energy Star 2010 (North-Central)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window29 - 5945

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Air, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.39 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Triple, Non-metal, Air, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (South-Central, North-Central, Southern, Northern)
  • Exceeds IECC 2012 (4B, 5C, 7, 4A, 5B, 5A, 4C, 6A, 6C, 8, 6B)
  • Exceeds IECC 2009 (1A, 3C, 7, 4A, 5A, 2C, 3A, 6C, 8, 6B, 3B, 2A, 4C, 6A, 5C, 4B, 1B, 1C, 2B, 5B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window30 - 6046

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Air, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.39 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Triple, Non-metal, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (5B, 4A, 5C, 4B, 6B, 7, 6A, 6C, 5A, 4C, 8)
  • Exceeds IECC 2012 (4A, 5B, 4B, 5C, 6B, 7, 6A, 6C, 5A, 4C, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window31 - 6147

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Air, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.39 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Triple, Non-metal, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (6B, 3B, 2A, 4C, 6A, 1A, 3C, 5C, 4B, 1B, 7, 1C, 2B, 5B, 4A, 5A, 2C, 3A, 6C, 8)
  • Exceeds IECC 2012 (8, 6B, 4A, 5B, 5A, 4C, 6A, 6C, 4B, 5C, 7)
  • Exceeds Energy Star 2010 (South-Central, North-Central, Southern, Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window31 - 6247

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Air, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (3B, 2C, 3A, 1B, 1A, 3C, 2B, 1C, 2A)

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Air, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.32 Btu/h-ft^2-R

Performance Standards:

  • Meets IECC 2012 (5C, 6B, 7, 5B, 5A, 4C, 6A, 6C, 8)
  • Exceeds IECC 2009 (5C, 4B, 7, 5B, 4A, 5A, 4C, 6A, 6C, 8, 6B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window28 - 5744

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Air, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (3B, 2C, 3A, 1B, 1A, 3C, 2B, 1C, 2A)

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Air, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (8, 6B, 7, 6A, 6C, 5A, 4C, 4A, 5B, 4B, 5C)
  • Exceeds IECC 2009 (8, 6B, 7, 6A, 6C, 5A, 4C, 5B, 4A, 5C, 4B)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window30 - 6046

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Air, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (3B, 2C, 3A, 1B, 1A, 3C, 2B, 1C, 2A)

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Air, M-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (5B, 5C, 8, 6B, 7, 6A, 6C, 5A, 4C)
  • Exceeds IECC 2009 (8, 6B, 7, 6A, 6C, 5A, 4C, 5B, 4A, 5C, 4B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window29 - 5845

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Air, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (3B, 2C, 3A, 1B, 1A, 3C, 2B, 1C, 2A)

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (5C, 4B, 7, 5B, 4A, 5A, 4C, 6A, 6C, 8, 6B)
  • Exceeds IECC 2012 (5C, 6B, 7, 5B, 5A, 4C, 6A, 6C, 8)
  • Exceeds Energy Star 2010 (Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window30 - 6046

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Air, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (3B, 2C, 3A, 1B, 1A, 3C, 2B, 1C, 2A)

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.26 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2009 (6A, 4C, 5B, 4A, 5C, 8, 4B, 6B, 7, 6C, 5A)
  • Exceeds IECC 2012 (6A, 4C, 4A, 5B, 4B, 5C, 8, 6B, 7, 6C, 5A)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window32 - 6349

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Air, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (3B, 2C, 3A, 1B, 1A, 3C, 2B, 1C, 2A)

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Arg, M-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (4C, 6A, 6C, 5C, 8, 6B, 7, 5B, 5A)
  • Exceeds IECC 2009 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)
  • Exceeds Energy Star 2010 (Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window31 - 6248

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Air, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (3B, 2C, 3A, 1B, 1A, 3C, 2B, 1C, 2A)

Lifetime:

  • 30 Years
 

Low-E, Double, Non-metal, Air, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (3B, 2C, 3A, 1B, 1A, 3C, 2B, 1C, 2A)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window23 - 4736

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Air, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (3B, 2C, 3A, 1B, 1A, 3C, 2B, 1C, 2A)

Lifetime:

  • 30 Years
 

Low-E, Double, Non-metal, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window23 - 4736

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Air, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (3B, 2C, 3A, 1B, 1A, 3C, 2B, 1C, 2A)

Lifetime:

  • 30 Years
 

Low-E, Double, Non-metal, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.34 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (South-Central)
  • Exceeds IECC 2012 (4A, 4B)
  • Exceeds IECC 2009 (8, 6A, 4C, 2A, 3B, 5B, 4A, 2B, 1C, 7, 1B, 5C, 4B, 1A, 3C, 6C, 2C, 3A, 5A, 6B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window25 - 5039

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Air, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (3B, 2C, 3A, 1B, 1A, 3C, 2B, 1C, 2A)

Lifetime:

  • 30 Years
 

Low-E, Double, Non-metal, Arg, M-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.35 Btu/h-ft^2-R

Performance Standards:

  • Meets IECC 2009 (5C, 4B, 7, 5B, 4A, 5A, 4C, 6A, 6C, 8, 6B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window24 - 4938

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Air, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (3B, 2C, 3A, 1B, 1A, 3C, 2B, 1C, 2A)

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Air, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.21 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2009 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)
  • Exceeds IECC 2012 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window36 - 7255

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Air, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (3B, 2C, 3A, 1B, 1A, 3C, 2B, 1C, 2A)

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Air, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.19 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (North-Central, Southern, Northern, South-Central)
  • Exceeds IECC 2009 (6B, 6A, 3B, 2A, 4C, 1C, 2B, 5B, 4A, 1A, 3C, 5C, 4B, 1B, 7, 2C, 3A, 6C, 5A, 8)
  • Exceeds IECC 2012 (8, 6B, 7, 6A, 6C, 5A, 4C, 4A, 5B, 4B, 5C)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window37 - 7256

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Air, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (3B, 2C, 3A, 1B, 1A, 3C, 2B, 1C, 2A)

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.18 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (8, 6B, 5B, 4A, 5A, 4C, 6A, 6C, 5C, 4B, 7)
  • Exceeds IECC 2009 (8, 6B, 5B, 4A, 5A, 4C, 6A, 6C, 5C, 4B, 7)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window38 - 7457

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Air, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (3B, 2C, 3A, 1B, 1A, 3C, 2B, 1C, 2A)

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.17 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (Northern, North-Central, Southern, South-Central)
  • Exceeds IECC 2009 (6C, 5A, 2B, 5B, 4A, 1C, 1B, 7, 1A, 3C, 5C, 4B, 6A, 2A, 4C, 3B, 6B, 8, 2C, 3A)
  • Exceeds IECC 2012 (6C, 5A, 4A, 5B, 6B, 7, 4B, 5C, 8, 6A, 4C)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window38 - 7557

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Air, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (3B, 2C, 3A, 1B, 1A, 3C, 2B, 1C, 2A)

Lifetime:

  • 30 Years
 

Low-E, Triple, Non-metal, Air, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (4C, 6A, 6C, 4B, 5C, 8, 6B, 7, 4A, 5B, 5A)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2009 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)
  • Exceeds Energy Star 2010 (North-Central)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window29 - 5945

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Air, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (3B, 2C, 3A, 1B, 1A, 3C, 2B, 1C, 2A)

Lifetime:

  • 30 Years
 

Low-E, Triple, Non-metal, Air, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (South-Central, North-Central, Southern, Northern)
  • Exceeds IECC 2012 (4B, 5C, 7, 4A, 5B, 5A, 4C, 6A, 6C, 8, 6B)
  • Exceeds IECC 2009 (1A, 3C, 7, 4A, 5A, 2C, 3A, 6C, 8, 6B, 3B, 2A, 4C, 6A, 5C, 4B, 1B, 1C, 2B, 5B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window30 - 6046

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Air, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (3B, 2C, 3A, 1B, 1A, 3C, 2B, 1C, 2A)

Lifetime:

  • 30 Years
 

Low-E, Triple, Non-metal, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (5B, 4A, 5C, 4B, 6B, 7, 6A, 6C, 5A, 4C, 8)
  • Exceeds IECC 2012 (4A, 5B, 4B, 5C, 6B, 7, 6A, 6C, 5A, 4C, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window31 - 6147

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Air, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (3B, 2C, 3A, 1B, 1A, 3C, 2B, 1C, 2A)

Lifetime:

  • 30 Years
 

Low-E, Triple, Non-metal, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (6B, 3B, 2A, 4C, 6A, 1A, 3C, 5C, 4B, 1B, 7, 1C, 2B, 5B, 4A, 5A, 2C, 3A, 6C, 8)
  • Exceeds IECC 2012 (8, 6B, 4A, 5B, 5A, 4C, 6A, 6C, 4B, 5C, 7)
  • Exceeds Energy Star 2010 (South-Central, North-Central, Southern, Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window31 - 6247

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Air, M-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.38 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Air, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.32 Btu/h-ft^2-R

Performance Standards:

  • Meets IECC 2012 (5C, 6B, 7, 5B, 5A, 4C, 6A, 6C, 8)
  • Exceeds IECC 2009 (5C, 4B, 7, 5B, 4A, 5A, 4C, 6A, 6C, 8, 6B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window28 - 5744

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Air, M-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.38 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Air, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (8, 6B, 7, 6A, 6C, 5A, 4C, 4A, 5B, 4B, 5C)
  • Exceeds IECC 2009 (8, 6B, 7, 6A, 6C, 5A, 4C, 5B, 4A, 5C, 4B)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window30 - 6046

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Air, M-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.38 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Air, M-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (5B, 5C, 8, 6B, 7, 6A, 6C, 5A, 4C)
  • Exceeds IECC 2009 (8, 6B, 7, 6A, 6C, 5A, 4C, 5B, 4A, 5C, 4B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window29 - 5845

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Air, M-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.38 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (5C, 4B, 7, 5B, 4A, 5A, 4C, 6A, 6C, 8, 6B)
  • Exceeds IECC 2012 (5C, 6B, 7, 5B, 5A, 4C, 6A, 6C, 8)
  • Exceeds Energy Star 2010 (Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window30 - 6046

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Air, M-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.38 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.26 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2009 (6A, 4C, 5B, 4A, 5C, 8, 4B, 6B, 7, 6C, 5A)
  • Exceeds IECC 2012 (6A, 4C, 4A, 5B, 4B, 5C, 8, 6B, 7, 6C, 5A)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window32 - 6349

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Air, M-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.38 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Arg, M-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (4C, 6A, 6C, 5C, 8, 6B, 7, 5B, 5A)
  • Exceeds IECC 2009 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)
  • Exceeds Energy Star 2010 (Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window31 - 6248

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Air, M-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.38 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Non-metal, Air, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (3B, 2C, 3A, 1B, 1A, 3C, 2B, 1C, 2A)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window23 - 4736

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Air, M-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.38 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Non-metal, Air, M-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.38 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window22 - 4535

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Air, M-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.38 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Non-metal, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window23 - 4736

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Air, M-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.38 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Non-metal, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.34 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (South-Central)
  • Exceeds IECC 2012 (4A, 4B)
  • Exceeds IECC 2009 (8, 6A, 4C, 2A, 3B, 5B, 4A, 2B, 1C, 7, 1B, 5C, 4B, 1A, 3C, 6C, 2C, 3A, 5A, 6B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window25 - 5039

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Air, M-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.38 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Non-metal, Arg, M-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.35 Btu/h-ft^2-R

Performance Standards:

  • Meets IECC 2009 (5C, 4B, 7, 5B, 4A, 5A, 4C, 6A, 6C, 8, 6B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window24 - 4938

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Air, M-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.38 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Air, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.21 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2009 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)
  • Exceeds IECC 2012 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window36 - 7255

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Air, M-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.38 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Air, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.19 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (North-Central, Southern, Northern, South-Central)
  • Exceeds IECC 2009 (6B, 6A, 3B, 2A, 4C, 1C, 2B, 5B, 4A, 1A, 3C, 5C, 4B, 1B, 7, 2C, 3A, 6C, 5A, 8)
  • Exceeds IECC 2012 (8, 6B, 7, 6A, 6C, 5A, 4C, 4A, 5B, 4B, 5C)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window37 - 7256

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Air, M-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.38 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.18 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (8, 6B, 5B, 4A, 5A, 4C, 6A, 6C, 5C, 4B, 7)
  • Exceeds IECC 2009 (8, 6B, 5B, 4A, 5A, 4C, 6A, 6C, 5C, 4B, 7)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window38 - 7457

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Air, M-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.38 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.17 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (Northern, North-Central, Southern, South-Central)
  • Exceeds IECC 2009 (6C, 5A, 2B, 5B, 4A, 1C, 1B, 7, 1A, 3C, 5C, 4B, 6A, 2A, 4C, 3B, 6B, 8, 2C, 3A)
  • Exceeds IECC 2012 (6C, 5A, 4A, 5B, 6B, 7, 4B, 5C, 8, 6A, 4C)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window38 - 7557

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Air, M-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.38 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Triple, Non-metal, Air, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (4C, 6A, 6C, 4B, 5C, 8, 6B, 7, 4A, 5B, 5A)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2009 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)
  • Exceeds Energy Star 2010 (North-Central)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window29 - 5945

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Air, M-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.38 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Triple, Non-metal, Air, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (South-Central, North-Central, Southern, Northern)
  • Exceeds IECC 2012 (4B, 5C, 7, 4A, 5B, 5A, 4C, 6A, 6C, 8, 6B)
  • Exceeds IECC 2009 (1A, 3C, 7, 4A, 5A, 2C, 3A, 6C, 8, 6B, 3B, 2A, 4C, 6A, 5C, 4B, 1B, 1C, 2B, 5B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window30 - 6046

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Air, M-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.38 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Triple, Non-metal, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (5B, 4A, 5C, 4B, 6B, 7, 6A, 6C, 5A, 4C, 8)
  • Exceeds IECC 2012 (4A, 5B, 4B, 5C, 6B, 7, 6A, 6C, 5A, 4C, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window31 - 6147

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Air, M-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.38 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Triple, Non-metal, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (6B, 3B, 2A, 4C, 6A, 1A, 3C, 5C, 4B, 1B, 7, 1C, 2B, 5B, 4A, 5A, 2C, 3A, 6C, 8)
  • Exceeds IECC 2012 (8, 6B, 4A, 5B, 5A, 4C, 6A, 6C, 4B, 5C, 7)
  • Exceeds Energy Star 2010 (South-Central, North-Central, Southern, Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window31 - 6247

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Air, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.32 Btu/h-ft^2-R

Performance Standards:

  • Meets IECC 2012 (5C, 6B, 7, 5B, 5A, 4C, 6A, 6C, 8)
  • Exceeds IECC 2009 (5C, 4B, 7, 5B, 4A, 5A, 4C, 6A, 6C, 8, 6B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window28 - 5744

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Air, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (8, 6B, 7, 6A, 6C, 5A, 4C, 4A, 5B, 4B, 5C)
  • Exceeds IECC 2009 (8, 6B, 7, 6A, 6C, 5A, 4C, 5B, 4A, 5C, 4B)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window30 - 6046

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Air, M-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (5B, 5C, 8, 6B, 7, 6A, 6C, 5A, 4C)
  • Exceeds IECC 2009 (8, 6B, 7, 6A, 6C, 5A, 4C, 5B, 4A, 5C, 4B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window29 - 5845

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (5C, 4B, 7, 5B, 4A, 5A, 4C, 6A, 6C, 8, 6B)
  • Exceeds IECC 2012 (5C, 6B, 7, 5B, 5A, 4C, 6A, 6C, 8)
  • Exceeds Energy Star 2010 (Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window30 - 6046

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.26 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2009 (6A, 4C, 5B, 4A, 5C, 8, 4B, 6B, 7, 6C, 5A)
  • Exceeds IECC 2012 (6A, 4C, 4A, 5B, 4B, 5C, 8, 6B, 7, 6C, 5A)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window32 - 6349

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Arg, M-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (4C, 6A, 6C, 5C, 8, 6B, 7, 5B, 5A)
  • Exceeds IECC 2009 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)
  • Exceeds Energy Star 2010 (Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window31 - 6248

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Non-metal, Air, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (3B, 2C, 3A, 1B, 1A, 3C, 2B, 1C, 2A)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window23 - 4736

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Non-metal, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window23 - 4736

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Non-metal, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.34 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (South-Central)
  • Exceeds IECC 2012 (4A, 4B)
  • Exceeds IECC 2009 (8, 6A, 4C, 2A, 3B, 5B, 4A, 2B, 1C, 7, 1B, 5C, 4B, 1A, 3C, 6C, 2C, 3A, 5A, 6B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window25 - 5039

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Non-metal, Arg, M-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.35 Btu/h-ft^2-R

Performance Standards:

  • Meets IECC 2009 (5C, 4B, 7, 5B, 4A, 5A, 4C, 6A, 6C, 8, 6B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window24 - 4938

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Air, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.21 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2009 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)
  • Exceeds IECC 2012 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window36 - 7255

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Air, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.19 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (North-Central, Southern, Northern, South-Central)
  • Exceeds IECC 2009 (6B, 6A, 3B, 2A, 4C, 1C, 2B, 5B, 4A, 1A, 3C, 5C, 4B, 1B, 7, 2C, 3A, 6C, 5A, 8)
  • Exceeds IECC 2012 (8, 6B, 7, 6A, 6C, 5A, 4C, 4A, 5B, 4B, 5C)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window37 - 7256

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.18 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (8, 6B, 5B, 4A, 5A, 4C, 6A, 6C, 5C, 4B, 7)
  • Exceeds IECC 2009 (8, 6B, 5B, 4A, 5A, 4C, 6A, 6C, 5C, 4B, 7)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window38 - 7457

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.17 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (Northern, North-Central, Southern, South-Central)
  • Exceeds IECC 2009 (6C, 5A, 2B, 5B, 4A, 1C, 1B, 7, 1A, 3C, 5C, 4B, 6A, 2A, 4C, 3B, 6B, 8, 2C, 3A)
  • Exceeds IECC 2012 (6C, 5A, 4A, 5B, 6B, 7, 4B, 5C, 8, 6A, 4C)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window38 - 7557

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Triple, Non-metal, Air, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (4C, 6A, 6C, 4B, 5C, 8, 6B, 7, 4A, 5B, 5A)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2009 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)
  • Exceeds Energy Star 2010 (North-Central)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window29 - 5945

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Triple, Non-metal, Air, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (South-Central, North-Central, Southern, Northern)
  • Exceeds IECC 2012 (4B, 5C, 7, 4A, 5B, 5A, 4C, 6A, 6C, 8, 6B)
  • Exceeds IECC 2009 (1A, 3C, 7, 4A, 5A, 2C, 3A, 6C, 8, 6B, 3B, 2A, 4C, 6A, 5C, 4B, 1B, 1C, 2B, 5B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window30 - 6046

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Triple, Non-metal, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (5B, 4A, 5C, 4B, 6B, 7, 6A, 6C, 5A, 4C, 8)
  • Exceeds IECC 2012 (4A, 5B, 4B, 5C, 6B, 7, 6A, 6C, 5A, 4C, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window31 - 6147

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Triple, Non-metal, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (6B, 3B, 2A, 4C, 6A, 1A, 3C, 5C, 4B, 1B, 7, 1C, 2B, 5B, 4A, 5A, 2C, 3A, 6C, 8)
  • Exceeds IECC 2012 (8, 6B, 4A, 5B, 5A, 4C, 6A, 6C, 4B, 5C, 7)
  • Exceeds Energy Star 2010 (South-Central, North-Central, Southern, Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window31 - 6247

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.34 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (South-Central)
  • Exceeds IECC 2012 (4A, 4B)
  • Exceeds IECC 2009 (8, 6A, 4C, 2A, 3B, 5B, 4A, 2B, 1C, 7, 1B, 5C, 4B, 1A, 3C, 6C, 2C, 3A, 5A, 6B)

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Air, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.32 Btu/h-ft^2-R

Performance Standards:

  • Meets IECC 2012 (5C, 6B, 7, 5B, 5A, 4C, 6A, 6C, 8)
  • Exceeds IECC 2009 (5C, 4B, 7, 5B, 4A, 5A, 4C, 6A, 6C, 8, 6B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window28 - 5744

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.34 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (South-Central)
  • Exceeds IECC 2012 (4A, 4B)
  • Exceeds IECC 2009 (8, 6A, 4C, 2A, 3B, 5B, 4A, 2B, 1C, 7, 1B, 5C, 4B, 1A, 3C, 6C, 2C, 3A, 5A, 6B)

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Air, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (8, 6B, 7, 6A, 6C, 5A, 4C, 4A, 5B, 4B, 5C)
  • Exceeds IECC 2009 (8, 6B, 7, 6A, 6C, 5A, 4C, 5B, 4A, 5C, 4B)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window30 - 6046

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.34 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (South-Central)
  • Exceeds IECC 2012 (4A, 4B)
  • Exceeds IECC 2009 (8, 6A, 4C, 2A, 3B, 5B, 4A, 2B, 1C, 7, 1B, 5C, 4B, 1A, 3C, 6C, 2C, 3A, 5A, 6B)

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Air, M-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (5B, 5C, 8, 6B, 7, 6A, 6C, 5A, 4C)
  • Exceeds IECC 2009 (8, 6B, 7, 6A, 6C, 5A, 4C, 5B, 4A, 5C, 4B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window29 - 5845

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.34 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (South-Central)
  • Exceeds IECC 2012 (4A, 4B)
  • Exceeds IECC 2009 (8, 6A, 4C, 2A, 3B, 5B, 4A, 2B, 1C, 7, 1B, 5C, 4B, 1A, 3C, 6C, 2C, 3A, 5A, 6B)

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (5C, 4B, 7, 5B, 4A, 5A, 4C, 6A, 6C, 8, 6B)
  • Exceeds IECC 2012 (5C, 6B, 7, 5B, 5A, 4C, 6A, 6C, 8)
  • Exceeds Energy Star 2010 (Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window30 - 6046

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.34 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (South-Central)
  • Exceeds IECC 2012 (4A, 4B)
  • Exceeds IECC 2009 (8, 6A, 4C, 2A, 3B, 5B, 4A, 2B, 1C, 7, 1B, 5C, 4B, 1A, 3C, 6C, 2C, 3A, 5A, 6B)

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.26 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2009 (6A, 4C, 5B, 4A, 5C, 8, 4B, 6B, 7, 6C, 5A)
  • Exceeds IECC 2012 (6A, 4C, 4A, 5B, 4B, 5C, 8, 6B, 7, 6C, 5A)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window32 - 6349

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.34 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (South-Central)
  • Exceeds IECC 2012 (4A, 4B)
  • Exceeds IECC 2009 (8, 6A, 4C, 2A, 3B, 5B, 4A, 2B, 1C, 7, 1B, 5C, 4B, 1A, 3C, 6C, 2C, 3A, 5A, 6B)

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Arg, M-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (4C, 6A, 6C, 5C, 8, 6B, 7, 5B, 5A)
  • Exceeds IECC 2009 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)
  • Exceeds Energy Star 2010 (Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window31 - 6248

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.34 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (South-Central)
  • Exceeds IECC 2012 (4A, 4B)
  • Exceeds IECC 2009 (8, 6A, 4C, 2A, 3B, 5B, 4A, 2B, 1C, 7, 1B, 5C, 4B, 1A, 3C, 6C, 2C, 3A, 5A, 6B)

Lifetime:

  • 30 Years
 

Low-E, Double, Non-metal, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.34 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (South-Central)
  • Exceeds IECC 2012 (4A, 4B)
  • Exceeds IECC 2009 (8, 6A, 4C, 2A, 3B, 5B, 4A, 2B, 1C, 7, 1B, 5C, 4B, 1A, 3C, 6C, 2C, 3A, 5A, 6B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window25 - 5039

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.34 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (South-Central)
  • Exceeds IECC 2012 (4A, 4B)
  • Exceeds IECC 2009 (8, 6A, 4C, 2A, 3B, 5B, 4A, 2B, 1C, 7, 1B, 5C, 4B, 1A, 3C, 6C, 2C, 3A, 5A, 6B)

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Air, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.21 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2009 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)
  • Exceeds IECC 2012 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window36 - 7255

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.34 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (South-Central)
  • Exceeds IECC 2012 (4A, 4B)
  • Exceeds IECC 2009 (8, 6A, 4C, 2A, 3B, 5B, 4A, 2B, 1C, 7, 1B, 5C, 4B, 1A, 3C, 6C, 2C, 3A, 5A, 6B)

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Air, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.19 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (North-Central, Southern, Northern, South-Central)
  • Exceeds IECC 2009 (6B, 6A, 3B, 2A, 4C, 1C, 2B, 5B, 4A, 1A, 3C, 5C, 4B, 1B, 7, 2C, 3A, 6C, 5A, 8)
  • Exceeds IECC 2012 (8, 6B, 7, 6A, 6C, 5A, 4C, 4A, 5B, 4B, 5C)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window37 - 7256

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.34 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (South-Central)
  • Exceeds IECC 2012 (4A, 4B)
  • Exceeds IECC 2009 (8, 6A, 4C, 2A, 3B, 5B, 4A, 2B, 1C, 7, 1B, 5C, 4B, 1A, 3C, 6C, 2C, 3A, 5A, 6B)

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.18 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (8, 6B, 5B, 4A, 5A, 4C, 6A, 6C, 5C, 4B, 7)
  • Exceeds IECC 2009 (8, 6B, 5B, 4A, 5A, 4C, 6A, 6C, 5C, 4B, 7)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window38 - 7457

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.34 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (South-Central)
  • Exceeds IECC 2012 (4A, 4B)
  • Exceeds IECC 2009 (8, 6A, 4C, 2A, 3B, 5B, 4A, 2B, 1C, 7, 1B, 5C, 4B, 1A, 3C, 6C, 2C, 3A, 5A, 6B)

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.17 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (Northern, North-Central, Southern, South-Central)
  • Exceeds IECC 2009 (6C, 5A, 2B, 5B, 4A, 1C, 1B, 7, 1A, 3C, 5C, 4B, 6A, 2A, 4C, 3B, 6B, 8, 2C, 3A)
  • Exceeds IECC 2012 (6C, 5A, 4A, 5B, 6B, 7, 4B, 5C, 8, 6A, 4C)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window38 - 7557

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.34 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (South-Central)
  • Exceeds IECC 2012 (4A, 4B)
  • Exceeds IECC 2009 (8, 6A, 4C, 2A, 3B, 5B, 4A, 2B, 1C, 7, 1B, 5C, 4B, 1A, 3C, 6C, 2C, 3A, 5A, 6B)

Lifetime:

  • 30 Years
 

Low-E, Triple, Non-metal, Air, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (4C, 6A, 6C, 4B, 5C, 8, 6B, 7, 4A, 5B, 5A)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2009 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)
  • Exceeds Energy Star 2010 (North-Central)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window29 - 5945

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.34 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (South-Central)
  • Exceeds IECC 2012 (4A, 4B)
  • Exceeds IECC 2009 (8, 6A, 4C, 2A, 3B, 5B, 4A, 2B, 1C, 7, 1B, 5C, 4B, 1A, 3C, 6C, 2C, 3A, 5A, 6B)

Lifetime:

  • 30 Years
 

Low-E, Triple, Non-metal, Air, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (South-Central, North-Central, Southern, Northern)
  • Exceeds IECC 2012 (4B, 5C, 7, 4A, 5B, 5A, 4C, 6A, 6C, 8, 6B)
  • Exceeds IECC 2009 (1A, 3C, 7, 4A, 5A, 2C, 3A, 6C, 8, 6B, 3B, 2A, 4C, 6A, 5C, 4B, 1B, 1C, 2B, 5B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window30 - 6046

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.34 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (South-Central)
  • Exceeds IECC 2012 (4A, 4B)
  • Exceeds IECC 2009 (8, 6A, 4C, 2A, 3B, 5B, 4A, 2B, 1C, 7, 1B, 5C, 4B, 1A, 3C, 6C, 2C, 3A, 5A, 6B)

Lifetime:

  • 30 Years
 

Low-E, Triple, Non-metal, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (5B, 4A, 5C, 4B, 6B, 7, 6A, 6C, 5A, 4C, 8)
  • Exceeds IECC 2012 (4A, 5B, 4B, 5C, 6B, 7, 6A, 6C, 5A, 4C, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window31 - 6147

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.34 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (South-Central)
  • Exceeds IECC 2012 (4A, 4B)
  • Exceeds IECC 2009 (8, 6A, 4C, 2A, 3B, 5B, 4A, 2B, 1C, 7, 1B, 5C, 4B, 1A, 3C, 6C, 2C, 3A, 5A, 6B)

Lifetime:

  • 30 Years
 

Low-E, Triple, Non-metal, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (6B, 3B, 2A, 4C, 6A, 1A, 3C, 5C, 4B, 1B, 7, 1C, 2B, 5B, 4A, 5A, 2C, 3A, 6C, 8)
  • Exceeds IECC 2012 (8, 6B, 4A, 5B, 5A, 4C, 6A, 6C, 4B, 5C, 7)
  • Exceeds Energy Star 2010 (South-Central, North-Central, Southern, Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window31 - 6247

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Arg, M-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.35 Btu/h-ft^2-R

Performance Standards:

  • Meets IECC 2009 (5C, 4B, 7, 5B, 4A, 5A, 4C, 6A, 6C, 8, 6B)

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Air, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.32 Btu/h-ft^2-R

Performance Standards:

  • Meets IECC 2012 (5C, 6B, 7, 5B, 5A, 4C, 6A, 6C, 8)
  • Exceeds IECC 2009 (5C, 4B, 7, 5B, 4A, 5A, 4C, 6A, 6C, 8, 6B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window28 - 5744

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Arg, M-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.35 Btu/h-ft^2-R

Performance Standards:

  • Meets IECC 2009 (5C, 4B, 7, 5B, 4A, 5A, 4C, 6A, 6C, 8, 6B)

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Air, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (8, 6B, 7, 6A, 6C, 5A, 4C, 4A, 5B, 4B, 5C)
  • Exceeds IECC 2009 (8, 6B, 7, 6A, 6C, 5A, 4C, 5B, 4A, 5C, 4B)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window30 - 6046

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Arg, M-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.35 Btu/h-ft^2-R

Performance Standards:

  • Meets IECC 2009 (5C, 4B, 7, 5B, 4A, 5A, 4C, 6A, 6C, 8, 6B)

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Air, M-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (5B, 5C, 8, 6B, 7, 6A, 6C, 5A, 4C)
  • Exceeds IECC 2009 (8, 6B, 7, 6A, 6C, 5A, 4C, 5B, 4A, 5C, 4B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window29 - 5845

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Arg, M-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.35 Btu/h-ft^2-R

Performance Standards:

  • Meets IECC 2009 (5C, 4B, 7, 5B, 4A, 5A, 4C, 6A, 6C, 8, 6B)

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (5C, 4B, 7, 5B, 4A, 5A, 4C, 6A, 6C, 8, 6B)
  • Exceeds IECC 2012 (5C, 6B, 7, 5B, 5A, 4C, 6A, 6C, 8)
  • Exceeds Energy Star 2010 (Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window30 - 6046

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Arg, M-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.35 Btu/h-ft^2-R

Performance Standards:

  • Meets IECC 2009 (5C, 4B, 7, 5B, 4A, 5A, 4C, 6A, 6C, 8, 6B)

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.26 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2009 (6A, 4C, 5B, 4A, 5C, 8, 4B, 6B, 7, 6C, 5A)
  • Exceeds IECC 2012 (6A, 4C, 4A, 5B, 4B, 5C, 8, 6B, 7, 6C, 5A)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window32 - 6349

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Arg, M-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.35 Btu/h-ft^2-R

Performance Standards:

  • Meets IECC 2009 (5C, 4B, 7, 5B, 4A, 5A, 4C, 6A, 6C, 8, 6B)

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Arg, M-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (4C, 6A, 6C, 5C, 8, 6B, 7, 5B, 5A)
  • Exceeds IECC 2009 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)
  • Exceeds Energy Star 2010 (Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window31 - 6248

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Arg, M-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.35 Btu/h-ft^2-R

Performance Standards:

  • Meets IECC 2009 (5C, 4B, 7, 5B, 4A, 5A, 4C, 6A, 6C, 8, 6B)

Lifetime:

  • 30 Years
 

Low-E, Double, Non-metal, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.34 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (South-Central)
  • Exceeds IECC 2012 (4A, 4B)
  • Exceeds IECC 2009 (8, 6A, 4C, 2A, 3B, 5B, 4A, 2B, 1C, 7, 1B, 5C, 4B, 1A, 3C, 6C, 2C, 3A, 5A, 6B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window25 - 5039

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Arg, M-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.35 Btu/h-ft^2-R

Performance Standards:

  • Meets IECC 2009 (5C, 4B, 7, 5B, 4A, 5A, 4C, 6A, 6C, 8, 6B)

Lifetime:

  • 30 Years
 

Low-E, Double, Non-metal, Arg, M-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.35 Btu/h-ft^2-R

Performance Standards:

  • Meets IECC 2009 (5C, 4B, 7, 5B, 4A, 5A, 4C, 6A, 6C, 8, 6B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window24 - 4938

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Arg, M-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.35 Btu/h-ft^2-R

Performance Standards:

  • Meets IECC 2009 (5C, 4B, 7, 5B, 4A, 5A, 4C, 6A, 6C, 8, 6B)

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Air, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.21 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2009 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)
  • Exceeds IECC 2012 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window36 - 7255

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Arg, M-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.35 Btu/h-ft^2-R

Performance Standards:

  • Meets IECC 2009 (5C, 4B, 7, 5B, 4A, 5A, 4C, 6A, 6C, 8, 6B)

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Air, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.19 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (North-Central, Southern, Northern, South-Central)
  • Exceeds IECC 2009 (6B, 6A, 3B, 2A, 4C, 1C, 2B, 5B, 4A, 1A, 3C, 5C, 4B, 1B, 7, 2C, 3A, 6C, 5A, 8)
  • Exceeds IECC 2012 (8, 6B, 7, 6A, 6C, 5A, 4C, 4A, 5B, 4B, 5C)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window37 - 7256

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Arg, M-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.35 Btu/h-ft^2-R

Performance Standards:

  • Meets IECC 2009 (5C, 4B, 7, 5B, 4A, 5A, 4C, 6A, 6C, 8, 6B)

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.18 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (8, 6B, 5B, 4A, 5A, 4C, 6A, 6C, 5C, 4B, 7)
  • Exceeds IECC 2009 (8, 6B, 5B, 4A, 5A, 4C, 6A, 6C, 5C, 4B, 7)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window38 - 7457

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Arg, M-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.35 Btu/h-ft^2-R

Performance Standards:

  • Meets IECC 2009 (5C, 4B, 7, 5B, 4A, 5A, 4C, 6A, 6C, 8, 6B)

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.17 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (Northern, North-Central, Southern, South-Central)
  • Exceeds IECC 2009 (6C, 5A, 2B, 5B, 4A, 1C, 1B, 7, 1A, 3C, 5C, 4B, 6A, 2A, 4C, 3B, 6B, 8, 2C, 3A)
  • Exceeds IECC 2012 (6C, 5A, 4A, 5B, 6B, 7, 4B, 5C, 8, 6A, 4C)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window38 - 7557

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Arg, M-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.35 Btu/h-ft^2-R

Performance Standards:

  • Meets IECC 2009 (5C, 4B, 7, 5B, 4A, 5A, 4C, 6A, 6C, 8, 6B)

Lifetime:

  • 30 Years
 

Low-E, Triple, Non-metal, Air, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (4C, 6A, 6C, 4B, 5C, 8, 6B, 7, 4A, 5B, 5A)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2009 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)
  • Exceeds Energy Star 2010 (North-Central)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window29 - 5945

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Arg, M-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.35 Btu/h-ft^2-R

Performance Standards:

  • Meets IECC 2009 (5C, 4B, 7, 5B, 4A, 5A, 4C, 6A, 6C, 8, 6B)

Lifetime:

  • 30 Years
 

Low-E, Triple, Non-metal, Air, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (South-Central, North-Central, Southern, Northern)
  • Exceeds IECC 2012 (4B, 5C, 7, 4A, 5B, 5A, 4C, 6A, 6C, 8, 6B)
  • Exceeds IECC 2009 (1A, 3C, 7, 4A, 5A, 2C, 3A, 6C, 8, 6B, 3B, 2A, 4C, 6A, 5C, 4B, 1B, 1C, 2B, 5B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window30 - 6046

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Arg, M-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.35 Btu/h-ft^2-R

Performance Standards:

  • Meets IECC 2009 (5C, 4B, 7, 5B, 4A, 5A, 4C, 6A, 6C, 8, 6B)

Lifetime:

  • 30 Years
 

Low-E, Triple, Non-metal, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (5B, 4A, 5C, 4B, 6B, 7, 6A, 6C, 5A, 4C, 8)
  • Exceeds IECC 2012 (4A, 5B, 4B, 5C, 6B, 7, 6A, 6C, 5A, 4C, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window31 - 6147

Replace Window:

Before-Component After-Component Cost

Low-E, Double, Non-metal, Arg, M-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.35 Btu/h-ft^2-R

Performance Standards:

  • Meets IECC 2009 (5C, 4B, 7, 5B, 4A, 5A, 4C, 6A, 6C, 8, 6B)

Lifetime:

  • 30 Years
 

Low-E, Triple, Non-metal, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (6B, 3B, 2A, 4C, 6A, 1A, 3C, 5C, 4B, 1B, 7, 1C, 2B, 5B, 4A, 5A, 2C, 3A, 6C, 8)
  • Exceeds IECC 2012 (8, 6B, 4A, 5B, 5A, 4C, 6A, 6C, 4B, 5C, 7)
  • Exceeds Energy Star 2010 (South-Central, North-Central, Southern, Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window31 - 6247

Replace Window:

Before-Component After-Component Cost

Low-E, Triple, Insulated, Air, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.21 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2009 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)
  • Exceeds IECC 2012 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Air, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.21 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2009 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)
  • Exceeds IECC 2012 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window36 - 7255

Replace Window:

Before-Component After-Component Cost

Low-E, Triple, Insulated, Air, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.21 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2009 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)
  • Exceeds IECC 2012 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Air, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.19 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (North-Central, Southern, Northern, South-Central)
  • Exceeds IECC 2009 (6B, 6A, 3B, 2A, 4C, 1C, 2B, 5B, 4A, 1A, 3C, 5C, 4B, 1B, 7, 2C, 3A, 6C, 5A, 8)
  • Exceeds IECC 2012 (8, 6B, 7, 6A, 6C, 5A, 4C, 4A, 5B, 4B, 5C)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window37 - 7256

Replace Window:

Before-Component After-Component Cost

Low-E, Triple, Insulated, Air, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.21 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2009 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)
  • Exceeds IECC 2012 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.18 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (8, 6B, 5B, 4A, 5A, 4C, 6A, 6C, 5C, 4B, 7)
  • Exceeds IECC 2009 (8, 6B, 5B, 4A, 5A, 4C, 6A, 6C, 5C, 4B, 7)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window38 - 7457

Replace Window:

Before-Component After-Component Cost

Low-E, Triple, Insulated, Air, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.21 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2009 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)
  • Exceeds IECC 2012 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.17 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (Northern, North-Central, Southern, South-Central)
  • Exceeds IECC 2009 (6C, 5A, 2B, 5B, 4A, 1C, 1B, 7, 1A, 3C, 5C, 4B, 6A, 2A, 4C, 3B, 6B, 8, 2C, 3A)
  • Exceeds IECC 2012 (6C, 5A, 4A, 5B, 6B, 7, 4B, 5C, 8, 6A, 4C)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window38 - 7557

Replace Window:

Before-Component After-Component Cost

Low-E, Triple, Insulated, Air, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.19 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (North-Central, Southern, Northern, South-Central)
  • Exceeds IECC 2009 (6B, 6A, 3B, 2A, 4C, 1C, 2B, 5B, 4A, 1A, 3C, 5C, 4B, 1B, 7, 2C, 3A, 6C, 5A, 8)
  • Exceeds IECC 2012 (8, 6B, 7, 6A, 6C, 5A, 4C, 4A, 5B, 4B, 5C)

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Air, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.19 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (North-Central, Southern, Northern, South-Central)
  • Exceeds IECC 2009 (6B, 6A, 3B, 2A, 4C, 1C, 2B, 5B, 4A, 1A, 3C, 5C, 4B, 1B, 7, 2C, 3A, 6C, 5A, 8)
  • Exceeds IECC 2012 (8, 6B, 7, 6A, 6C, 5A, 4C, 4A, 5B, 4B, 5C)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window37 - 7256

Replace Window:

Before-Component After-Component Cost

Low-E, Triple, Insulated, Air, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.19 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (North-Central, Southern, Northern, South-Central)
  • Exceeds IECC 2009 (6B, 6A, 3B, 2A, 4C, 1C, 2B, 5B, 4A, 1A, 3C, 5C, 4B, 1B, 7, 2C, 3A, 6C, 5A, 8)
  • Exceeds IECC 2012 (8, 6B, 7, 6A, 6C, 5A, 4C, 4A, 5B, 4B, 5C)

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.18 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (8, 6B, 5B, 4A, 5A, 4C, 6A, 6C, 5C, 4B, 7)
  • Exceeds IECC 2009 (8, 6B, 5B, 4A, 5A, 4C, 6A, 6C, 5C, 4B, 7)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window38 - 7457

Replace Window:

Before-Component After-Component Cost

Low-E, Triple, Insulated, Air, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.19 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (North-Central, Southern, Northern, South-Central)
  • Exceeds IECC 2009 (6B, 6A, 3B, 2A, 4C, 1C, 2B, 5B, 4A, 1A, 3C, 5C, 4B, 1B, 7, 2C, 3A, 6C, 5A, 8)
  • Exceeds IECC 2012 (8, 6B, 7, 6A, 6C, 5A, 4C, 4A, 5B, 4B, 5C)

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.17 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (Northern, North-Central, Southern, South-Central)
  • Exceeds IECC 2009 (6C, 5A, 2B, 5B, 4A, 1C, 1B, 7, 1A, 3C, 5C, 4B, 6A, 2A, 4C, 3B, 6B, 8, 2C, 3A)
  • Exceeds IECC 2012 (6C, 5A, 4A, 5B, 6B, 7, 4B, 5C, 8, 6A, 4C)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window38 - 7557

Replace Window:

Before-Component After-Component Cost

Low-E, Triple, Insulated, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.18 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (8, 6B, 5B, 4A, 5A, 4C, 6A, 6C, 5C, 4B, 7)
  • Exceeds IECC 2009 (8, 6B, 5B, 4A, 5A, 4C, 6A, 6C, 5C, 4B, 7)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.18 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (8, 6B, 5B, 4A, 5A, 4C, 6A, 6C, 5C, 4B, 7)
  • Exceeds IECC 2009 (8, 6B, 5B, 4A, 5A, 4C, 6A, 6C, 5C, 4B, 7)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window38 - 7457

Replace Window:

Before-Component After-Component Cost

Low-E, Triple, Insulated, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.18 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (8, 6B, 5B, 4A, 5A, 4C, 6A, 6C, 5C, 4B, 7)
  • Exceeds IECC 2009 (8, 6B, 5B, 4A, 5A, 4C, 6A, 6C, 5C, 4B, 7)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.17 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (Northern, North-Central, Southern, South-Central)
  • Exceeds IECC 2009 (6C, 5A, 2B, 5B, 4A, 1C, 1B, 7, 1A, 3C, 5C, 4B, 6A, 2A, 4C, 3B, 6B, 8, 2C, 3A)
  • Exceeds IECC 2012 (6C, 5A, 4A, 5B, 6B, 7, 4B, 5C, 8, 6A, 4C)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window38 - 7557

Replace Window:

Before-Component After-Component Cost

Low-E, Triple, Insulated, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.17 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (Northern, North-Central, Southern, South-Central)
  • Exceeds IECC 2009 (6C, 5A, 2B, 5B, 4A, 1C, 1B, 7, 1A, 3C, 5C, 4B, 6A, 2A, 4C, 3B, 6B, 8, 2C, 3A)
  • Exceeds IECC 2012 (6C, 5A, 4A, 5B, 6B, 7, 4B, 5C, 8, 6A, 4C)

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.17 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (Northern, North-Central, Southern, South-Central)
  • Exceeds IECC 2009 (6C, 5A, 2B, 5B, 4A, 1C, 1B, 7, 1A, 3C, 5C, 4B, 6A, 2A, 4C, 3B, 6B, 8, 2C, 3A)
  • Exceeds IECC 2012 (6C, 5A, 4A, 5B, 6B, 7, 4B, 5C, 8, 6A, 4C)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window38 - 7557

Replace Window:

Before-Component After-Component Cost

Low-E, Triple, Non-metal, Air, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (4C, 6A, 6C, 4B, 5C, 8, 6B, 7, 4A, 5B, 5A)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2009 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)
  • Exceeds Energy Star 2010 (North-Central)

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Air, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (8, 6B, 7, 6A, 6C, 5A, 4C, 4A, 5B, 4B, 5C)
  • Exceeds IECC 2009 (8, 6B, 7, 6A, 6C, 5A, 4C, 5B, 4A, 5C, 4B)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window30 - 6046

Replace Window:

Before-Component After-Component Cost

Low-E, Triple, Non-metal, Air, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (4C, 6A, 6C, 4B, 5C, 8, 6B, 7, 4A, 5B, 5A)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2009 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)
  • Exceeds Energy Star 2010 (North-Central)

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Air, M-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (5B, 5C, 8, 6B, 7, 6A, 6C, 5A, 4C)
  • Exceeds IECC 2009 (8, 6B, 7, 6A, 6C, 5A, 4C, 5B, 4A, 5C, 4B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window29 - 5845

Replace Window:

Before-Component After-Component Cost

Low-E, Triple, Non-metal, Air, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (4C, 6A, 6C, 4B, 5C, 8, 6B, 7, 4A, 5B, 5A)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2009 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)
  • Exceeds Energy Star 2010 (North-Central)

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (5C, 4B, 7, 5B, 4A, 5A, 4C, 6A, 6C, 8, 6B)
  • Exceeds IECC 2012 (5C, 6B, 7, 5B, 5A, 4C, 6A, 6C, 8)
  • Exceeds Energy Star 2010 (Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window30 - 6046

Replace Window:

Before-Component After-Component Cost

Low-E, Triple, Non-metal, Air, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (4C, 6A, 6C, 4B, 5C, 8, 6B, 7, 4A, 5B, 5A)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2009 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)
  • Exceeds Energy Star 2010 (North-Central)

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.26 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2009 (6A, 4C, 5B, 4A, 5C, 8, 4B, 6B, 7, 6C, 5A)
  • Exceeds IECC 2012 (6A, 4C, 4A, 5B, 4B, 5C, 8, 6B, 7, 6C, 5A)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window32 - 6349

Replace Window:

Before-Component After-Component Cost

Low-E, Triple, Non-metal, Air, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (4C, 6A, 6C, 4B, 5C, 8, 6B, 7, 4A, 5B, 5A)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2009 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)
  • Exceeds Energy Star 2010 (North-Central)

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Arg, M-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (4C, 6A, 6C, 5C, 8, 6B, 7, 5B, 5A)
  • Exceeds IECC 2009 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)
  • Exceeds Energy Star 2010 (Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window31 - 6248

Replace Window:

Before-Component After-Component Cost

Low-E, Triple, Non-metal, Air, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (4C, 6A, 6C, 4B, 5C, 8, 6B, 7, 4A, 5B, 5A)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2009 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)
  • Exceeds Energy Star 2010 (North-Central)

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Air, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.21 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2009 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)
  • Exceeds IECC 2012 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window36 - 7255

Replace Window:

Before-Component After-Component Cost

Low-E, Triple, Non-metal, Air, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (4C, 6A, 6C, 4B, 5C, 8, 6B, 7, 4A, 5B, 5A)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2009 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)
  • Exceeds Energy Star 2010 (North-Central)

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Air, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.19 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (North-Central, Southern, Northern, South-Central)
  • Exceeds IECC 2009 (6B, 6A, 3B, 2A, 4C, 1C, 2B, 5B, 4A, 1A, 3C, 5C, 4B, 1B, 7, 2C, 3A, 6C, 5A, 8)
  • Exceeds IECC 2012 (8, 6B, 7, 6A, 6C, 5A, 4C, 4A, 5B, 4B, 5C)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window37 - 7256

Replace Window:

Before-Component After-Component Cost

Low-E, Triple, Non-metal, Air, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (4C, 6A, 6C, 4B, 5C, 8, 6B, 7, 4A, 5B, 5A)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2009 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)
  • Exceeds Energy Star 2010 (North-Central)

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.18 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (8, 6B, 5B, 4A, 5A, 4C, 6A, 6C, 5C, 4B, 7)
  • Exceeds IECC 2009 (8, 6B, 5B, 4A, 5A, 4C, 6A, 6C, 5C, 4B, 7)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window38 - 7457

Replace Window:

Before-Component After-Component Cost

Low-E, Triple, Non-metal, Air, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (4C, 6A, 6C, 4B, 5C, 8, 6B, 7, 4A, 5B, 5A)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2009 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)
  • Exceeds Energy Star 2010 (North-Central)

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.17 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (Northern, North-Central, Southern, South-Central)
  • Exceeds IECC 2009 (6C, 5A, 2B, 5B, 4A, 1C, 1B, 7, 1A, 3C, 5C, 4B, 6A, 2A, 4C, 3B, 6B, 8, 2C, 3A)
  • Exceeds IECC 2012 (6C, 5A, 4A, 5B, 6B, 7, 4B, 5C, 8, 6A, 4C)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window38 - 7557

Replace Window:

Before-Component After-Component Cost

Low-E, Triple, Non-metal, Air, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (4C, 6A, 6C, 4B, 5C, 8, 6B, 7, 4A, 5B, 5A)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2009 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)
  • Exceeds Energy Star 2010 (North-Central)

Lifetime:

  • 30 Years
 

Low-E, Triple, Non-metal, Air, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (4C, 6A, 6C, 4B, 5C, 8, 6B, 7, 4A, 5B, 5A)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2009 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)
  • Exceeds Energy Star 2010 (North-Central)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window29 - 5945

Replace Window:

Before-Component After-Component Cost

Low-E, Triple, Non-metal, Air, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (4C, 6A, 6C, 4B, 5C, 8, 6B, 7, 4A, 5B, 5A)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2009 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)
  • Exceeds Energy Star 2010 (North-Central)

Lifetime:

  • 30 Years
 

Low-E, Triple, Non-metal, Air, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (South-Central, North-Central, Southern, Northern)
  • Exceeds IECC 2012 (4B, 5C, 7, 4A, 5B, 5A, 4C, 6A, 6C, 8, 6B)
  • Exceeds IECC 2009 (1A, 3C, 7, 4A, 5A, 2C, 3A, 6C, 8, 6B, 3B, 2A, 4C, 6A, 5C, 4B, 1B, 1C, 2B, 5B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window30 - 6046

Replace Window:

Before-Component After-Component Cost

Low-E, Triple, Non-metal, Air, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (4C, 6A, 6C, 4B, 5C, 8, 6B, 7, 4A, 5B, 5A)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2009 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)
  • Exceeds Energy Star 2010 (North-Central)

Lifetime:

  • 30 Years
 

Low-E, Triple, Non-metal, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (5B, 4A, 5C, 4B, 6B, 7, 6A, 6C, 5A, 4C, 8)
  • Exceeds IECC 2012 (4A, 5B, 4B, 5C, 6B, 7, 6A, 6C, 5A, 4C, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window31 - 6147

Replace Window:

Before-Component After-Component Cost

Low-E, Triple, Non-metal, Air, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (4C, 6A, 6C, 4B, 5C, 8, 6B, 7, 4A, 5B, 5A)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2009 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)
  • Exceeds Energy Star 2010 (North-Central)

Lifetime:

  • 30 Years
 

Low-E, Triple, Non-metal, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (6B, 3B, 2A, 4C, 6A, 1A, 3C, 5C, 4B, 1B, 7, 1C, 2B, 5B, 4A, 5A, 2C, 3A, 6C, 8)
  • Exceeds IECC 2012 (8, 6B, 4A, 5B, 5A, 4C, 6A, 6C, 4B, 5C, 7)
  • Exceeds Energy Star 2010 (South-Central, North-Central, Southern, Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window31 - 6247

Replace Window:

Before-Component After-Component Cost

Low-E, Triple, Non-metal, Air, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (South-Central, North-Central, Southern, Northern)
  • Exceeds IECC 2012 (4B, 5C, 7, 4A, 5B, 5A, 4C, 6A, 6C, 8, 6B)
  • Exceeds IECC 2009 (1A, 3C, 7, 4A, 5A, 2C, 3A, 6C, 8, 6B, 3B, 2A, 4C, 6A, 5C, 4B, 1B, 1C, 2B, 5B)

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Air, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (8, 6B, 7, 6A, 6C, 5A, 4C, 4A, 5B, 4B, 5C)
  • Exceeds IECC 2009 (8, 6B, 7, 6A, 6C, 5A, 4C, 5B, 4A, 5C, 4B)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window30 - 6046

Replace Window:

Before-Component After-Component Cost

Low-E, Triple, Non-metal, Air, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (South-Central, North-Central, Southern, Northern)
  • Exceeds IECC 2012 (4B, 5C, 7, 4A, 5B, 5A, 4C, 6A, 6C, 8, 6B)
  • Exceeds IECC 2009 (1A, 3C, 7, 4A, 5A, 2C, 3A, 6C, 8, 6B, 3B, 2A, 4C, 6A, 5C, 4B, 1B, 1C, 2B, 5B)

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (5C, 4B, 7, 5B, 4A, 5A, 4C, 6A, 6C, 8, 6B)
  • Exceeds IECC 2012 (5C, 6B, 7, 5B, 5A, 4C, 6A, 6C, 8)
  • Exceeds Energy Star 2010 (Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window30 - 6046

Replace Window:

Before-Component After-Component Cost

Low-E, Triple, Non-metal, Air, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (South-Central, North-Central, Southern, Northern)
  • Exceeds IECC 2012 (4B, 5C, 7, 4A, 5B, 5A, 4C, 6A, 6C, 8, 6B)
  • Exceeds IECC 2009 (1A, 3C, 7, 4A, 5A, 2C, 3A, 6C, 8, 6B, 3B, 2A, 4C, 6A, 5C, 4B, 1B, 1C, 2B, 5B)

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.26 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2009 (6A, 4C, 5B, 4A, 5C, 8, 4B, 6B, 7, 6C, 5A)
  • Exceeds IECC 2012 (6A, 4C, 4A, 5B, 4B, 5C, 8, 6B, 7, 6C, 5A)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window32 - 6349

Replace Window:

Before-Component After-Component Cost

Low-E, Triple, Non-metal, Air, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (South-Central, North-Central, Southern, Northern)
  • Exceeds IECC 2012 (4B, 5C, 7, 4A, 5B, 5A, 4C, 6A, 6C, 8, 6B)
  • Exceeds IECC 2009 (1A, 3C, 7, 4A, 5A, 2C, 3A, 6C, 8, 6B, 3B, 2A, 4C, 6A, 5C, 4B, 1B, 1C, 2B, 5B)

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Arg, M-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (4C, 6A, 6C, 5C, 8, 6B, 7, 5B, 5A)
  • Exceeds IECC 2009 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)
  • Exceeds Energy Star 2010 (Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window31 - 6248

Replace Window:

Before-Component After-Component Cost

Low-E, Triple, Non-metal, Air, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (South-Central, North-Central, Southern, Northern)
  • Exceeds IECC 2012 (4B, 5C, 7, 4A, 5B, 5A, 4C, 6A, 6C, 8, 6B)
  • Exceeds IECC 2009 (1A, 3C, 7, 4A, 5A, 2C, 3A, 6C, 8, 6B, 3B, 2A, 4C, 6A, 5C, 4B, 1B, 1C, 2B, 5B)

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Air, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.21 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2009 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)
  • Exceeds IECC 2012 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window36 - 7255

Replace Window:

Before-Component After-Component Cost

Low-E, Triple, Non-metal, Air, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (South-Central, North-Central, Southern, Northern)
  • Exceeds IECC 2012 (4B, 5C, 7, 4A, 5B, 5A, 4C, 6A, 6C, 8, 6B)
  • Exceeds IECC 2009 (1A, 3C, 7, 4A, 5A, 2C, 3A, 6C, 8, 6B, 3B, 2A, 4C, 6A, 5C, 4B, 1B, 1C, 2B, 5B)

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Air, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.19 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (North-Central, Southern, Northern, South-Central)
  • Exceeds IECC 2009 (6B, 6A, 3B, 2A, 4C, 1C, 2B, 5B, 4A, 1A, 3C, 5C, 4B, 1B, 7, 2C, 3A, 6C, 5A, 8)
  • Exceeds IECC 2012 (8, 6B, 7, 6A, 6C, 5A, 4C, 4A, 5B, 4B, 5C)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window37 - 7256

Replace Window:

Before-Component After-Component Cost

Low-E, Triple, Non-metal, Air, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (South-Central, North-Central, Southern, Northern)
  • Exceeds IECC 2012 (4B, 5C, 7, 4A, 5B, 5A, 4C, 6A, 6C, 8, 6B)
  • Exceeds IECC 2009 (1A, 3C, 7, 4A, 5A, 2C, 3A, 6C, 8, 6B, 3B, 2A, 4C, 6A, 5C, 4B, 1B, 1C, 2B, 5B)

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.18 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (8, 6B, 5B, 4A, 5A, 4C, 6A, 6C, 5C, 4B, 7)
  • Exceeds IECC 2009 (8, 6B, 5B, 4A, 5A, 4C, 6A, 6C, 5C, 4B, 7)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window38 - 7457

Replace Window:

Before-Component After-Component Cost

Low-E, Triple, Non-metal, Air, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (South-Central, North-Central, Southern, Northern)
  • Exceeds IECC 2012 (4B, 5C, 7, 4A, 5B, 5A, 4C, 6A, 6C, 8, 6B)
  • Exceeds IECC 2009 (1A, 3C, 7, 4A, 5A, 2C, 3A, 6C, 8, 6B, 3B, 2A, 4C, 6A, 5C, 4B, 1B, 1C, 2B, 5B)

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.17 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (Northern, North-Central, Southern, South-Central)
  • Exceeds IECC 2009 (6C, 5A, 2B, 5B, 4A, 1C, 1B, 7, 1A, 3C, 5C, 4B, 6A, 2A, 4C, 3B, 6B, 8, 2C, 3A)
  • Exceeds IECC 2012 (6C, 5A, 4A, 5B, 6B, 7, 4B, 5C, 8, 6A, 4C)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window38 - 7557

Replace Window:

Before-Component After-Component Cost

Low-E, Triple, Non-metal, Air, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (South-Central, North-Central, Southern, Northern)
  • Exceeds IECC 2012 (4B, 5C, 7, 4A, 5B, 5A, 4C, 6A, 6C, 8, 6B)
  • Exceeds IECC 2009 (1A, 3C, 7, 4A, 5A, 2C, 3A, 6C, 8, 6B, 3B, 2A, 4C, 6A, 5C, 4B, 1B, 1C, 2B, 5B)

Lifetime:

  • 30 Years
 

Low-E, Triple, Non-metal, Air, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (South-Central, North-Central, Southern, Northern)
  • Exceeds IECC 2012 (4B, 5C, 7, 4A, 5B, 5A, 4C, 6A, 6C, 8, 6B)
  • Exceeds IECC 2009 (1A, 3C, 7, 4A, 5A, 2C, 3A, 6C, 8, 6B, 3B, 2A, 4C, 6A, 5C, 4B, 1B, 1C, 2B, 5B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window30 - 6046

Replace Window:

Before-Component After-Component Cost

Low-E, Triple, Non-metal, Air, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (South-Central, North-Central, Southern, Northern)
  • Exceeds IECC 2012 (4B, 5C, 7, 4A, 5B, 5A, 4C, 6A, 6C, 8, 6B)
  • Exceeds IECC 2009 (1A, 3C, 7, 4A, 5A, 2C, 3A, 6C, 8, 6B, 3B, 2A, 4C, 6A, 5C, 4B, 1B, 1C, 2B, 5B)

Lifetime:

  • 30 Years
 

Low-E, Triple, Non-metal, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (5B, 4A, 5C, 4B, 6B, 7, 6A, 6C, 5A, 4C, 8)
  • Exceeds IECC 2012 (4A, 5B, 4B, 5C, 6B, 7, 6A, 6C, 5A, 4C, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window31 - 6147

Replace Window:

Before-Component After-Component Cost

Low-E, Triple, Non-metal, Air, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (South-Central, North-Central, Southern, Northern)
  • Exceeds IECC 2012 (4B, 5C, 7, 4A, 5B, 5A, 4C, 6A, 6C, 8, 6B)
  • Exceeds IECC 2009 (1A, 3C, 7, 4A, 5A, 2C, 3A, 6C, 8, 6B, 3B, 2A, 4C, 6A, 5C, 4B, 1B, 1C, 2B, 5B)

Lifetime:

  • 30 Years
 

Low-E, Triple, Non-metal, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (6B, 3B, 2A, 4C, 6A, 1A, 3C, 5C, 4B, 1B, 7, 1C, 2B, 5B, 4A, 5A, 2C, 3A, 6C, 8)
  • Exceeds IECC 2012 (8, 6B, 4A, 5B, 5A, 4C, 6A, 6C, 4B, 5C, 7)
  • Exceeds Energy Star 2010 (South-Central, North-Central, Southern, Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window31 - 6247

Replace Window:

Before-Component After-Component Cost

Low-E, Triple, Non-metal, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (5B, 4A, 5C, 4B, 6B, 7, 6A, 6C, 5A, 4C, 8)
  • Exceeds IECC 2012 (4A, 5B, 4B, 5C, 6B, 7, 6A, 6C, 5A, 4C, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Air, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (8, 6B, 7, 6A, 6C, 5A, 4C, 4A, 5B, 4B, 5C)
  • Exceeds IECC 2009 (8, 6B, 7, 6A, 6C, 5A, 4C, 5B, 4A, 5C, 4B)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window30 - 6046

Replace Window:

Before-Component After-Component Cost

Low-E, Triple, Non-metal, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (5B, 4A, 5C, 4B, 6B, 7, 6A, 6C, 5A, 4C, 8)
  • Exceeds IECC 2012 (4A, 5B, 4B, 5C, 6B, 7, 6A, 6C, 5A, 4C, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (5C, 4B, 7, 5B, 4A, 5A, 4C, 6A, 6C, 8, 6B)
  • Exceeds IECC 2012 (5C, 6B, 7, 5B, 5A, 4C, 6A, 6C, 8)
  • Exceeds Energy Star 2010 (Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window30 - 6046

Replace Window:

Before-Component After-Component Cost

Low-E, Triple, Non-metal, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (5B, 4A, 5C, 4B, 6B, 7, 6A, 6C, 5A, 4C, 8)
  • Exceeds IECC 2012 (4A, 5B, 4B, 5C, 6B, 7, 6A, 6C, 5A, 4C, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.26 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2009 (6A, 4C, 5B, 4A, 5C, 8, 4B, 6B, 7, 6C, 5A)
  • Exceeds IECC 2012 (6A, 4C, 4A, 5B, 4B, 5C, 8, 6B, 7, 6C, 5A)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window32 - 6349

Replace Window:

Before-Component After-Component Cost

Low-E, Triple, Non-metal, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (5B, 4A, 5C, 4B, 6B, 7, 6A, 6C, 5A, 4C, 8)
  • Exceeds IECC 2012 (4A, 5B, 4B, 5C, 6B, 7, 6A, 6C, 5A, 4C, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Arg, M-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (4C, 6A, 6C, 5C, 8, 6B, 7, 5B, 5A)
  • Exceeds IECC 2009 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)
  • Exceeds Energy Star 2010 (Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window31 - 6248

Replace Window:

Before-Component After-Component Cost

Low-E, Triple, Non-metal, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (5B, 4A, 5C, 4B, 6B, 7, 6A, 6C, 5A, 4C, 8)
  • Exceeds IECC 2012 (4A, 5B, 4B, 5C, 6B, 7, 6A, 6C, 5A, 4C, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Air, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.21 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2009 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)
  • Exceeds IECC 2012 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window36 - 7255

Replace Window:

Before-Component After-Component Cost

Low-E, Triple, Non-metal, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (5B, 4A, 5C, 4B, 6B, 7, 6A, 6C, 5A, 4C, 8)
  • Exceeds IECC 2012 (4A, 5B, 4B, 5C, 6B, 7, 6A, 6C, 5A, 4C, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Air, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.19 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (North-Central, Southern, Northern, South-Central)
  • Exceeds IECC 2009 (6B, 6A, 3B, 2A, 4C, 1C, 2B, 5B, 4A, 1A, 3C, 5C, 4B, 1B, 7, 2C, 3A, 6C, 5A, 8)
  • Exceeds IECC 2012 (8, 6B, 7, 6A, 6C, 5A, 4C, 4A, 5B, 4B, 5C)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window37 - 7256

Replace Window:

Before-Component After-Component Cost

Low-E, Triple, Non-metal, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (5B, 4A, 5C, 4B, 6B, 7, 6A, 6C, 5A, 4C, 8)
  • Exceeds IECC 2012 (4A, 5B, 4B, 5C, 6B, 7, 6A, 6C, 5A, 4C, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.18 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (8, 6B, 5B, 4A, 5A, 4C, 6A, 6C, 5C, 4B, 7)
  • Exceeds IECC 2009 (8, 6B, 5B, 4A, 5A, 4C, 6A, 6C, 5C, 4B, 7)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window38 - 7457

Replace Window:

Before-Component After-Component Cost

Low-E, Triple, Non-metal, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (5B, 4A, 5C, 4B, 6B, 7, 6A, 6C, 5A, 4C, 8)
  • Exceeds IECC 2012 (4A, 5B, 4B, 5C, 6B, 7, 6A, 6C, 5A, 4C, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.17 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (Northern, North-Central, Southern, South-Central)
  • Exceeds IECC 2009 (6C, 5A, 2B, 5B, 4A, 1C, 1B, 7, 1A, 3C, 5C, 4B, 6A, 2A, 4C, 3B, 6B, 8, 2C, 3A)
  • Exceeds IECC 2012 (6C, 5A, 4A, 5B, 6B, 7, 4B, 5C, 8, 6A, 4C)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window38 - 7557

Replace Window:

Before-Component After-Component Cost

Low-E, Triple, Non-metal, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (5B, 4A, 5C, 4B, 6B, 7, 6A, 6C, 5A, 4C, 8)
  • Exceeds IECC 2012 (4A, 5B, 4B, 5C, 6B, 7, 6A, 6C, 5A, 4C, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Low-E, Triple, Non-metal, Air, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (South-Central, North-Central, Southern, Northern)
  • Exceeds IECC 2012 (4B, 5C, 7, 4A, 5B, 5A, 4C, 6A, 6C, 8, 6B)
  • Exceeds IECC 2009 (1A, 3C, 7, 4A, 5A, 2C, 3A, 6C, 8, 6B, 3B, 2A, 4C, 6A, 5C, 4B, 1B, 1C, 2B, 5B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window30 - 6046

Replace Window:

Before-Component After-Component Cost

Low-E, Triple, Non-metal, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (5B, 4A, 5C, 4B, 6B, 7, 6A, 6C, 5A, 4C, 8)
  • Exceeds IECC 2012 (4A, 5B, 4B, 5C, 6B, 7, 6A, 6C, 5A, 4C, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Low-E, Triple, Non-metal, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (5B, 4A, 5C, 4B, 6B, 7, 6A, 6C, 5A, 4C, 8)
  • Exceeds IECC 2012 (4A, 5B, 4B, 5C, 6B, 7, 6A, 6C, 5A, 4C, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window31 - 6147

Replace Window:

Before-Component After-Component Cost

Low-E, Triple, Non-metal, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (5B, 4A, 5C, 4B, 6B, 7, 6A, 6C, 5A, 4C, 8)
  • Exceeds IECC 2012 (4A, 5B, 4B, 5C, 6B, 7, 6A, 6C, 5A, 4C, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Low-E, Triple, Non-metal, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (6B, 3B, 2A, 4C, 6A, 1A, 3C, 5C, 4B, 1B, 7, 1C, 2B, 5B, 4A, 5A, 2C, 3A, 6C, 8)
  • Exceeds IECC 2012 (8, 6B, 4A, 5B, 5A, 4C, 6A, 6C, 4B, 5C, 7)
  • Exceeds Energy Star 2010 (South-Central, North-Central, Southern, Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window31 - 6247

Replace Window:

Before-Component After-Component Cost

Low-E, Triple, Non-metal, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (6B, 3B, 2A, 4C, 6A, 1A, 3C, 5C, 4B, 1B, 7, 1C, 2B, 5B, 4A, 5A, 2C, 3A, 6C, 8)
  • Exceeds IECC 2012 (8, 6B, 4A, 5B, 5A, 4C, 6A, 6C, 4B, 5C, 7)
  • Exceeds Energy Star 2010 (South-Central, North-Central, Southern, Northern)

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.26 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2009 (6A, 4C, 5B, 4A, 5C, 8, 4B, 6B, 7, 6C, 5A)
  • Exceeds IECC 2012 (6A, 4C, 4A, 5B, 4B, 5C, 8, 6B, 7, 6C, 5A)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window32 - 6349

Replace Window:

Before-Component After-Component Cost

Low-E, Triple, Non-metal, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (6B, 3B, 2A, 4C, 6A, 1A, 3C, 5C, 4B, 1B, 7, 1C, 2B, 5B, 4A, 5A, 2C, 3A, 6C, 8)
  • Exceeds IECC 2012 (8, 6B, 4A, 5B, 5A, 4C, 6A, 6C, 4B, 5C, 7)
  • Exceeds Energy Star 2010 (South-Central, North-Central, Southern, Northern)

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Arg, M-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (4C, 6A, 6C, 5C, 8, 6B, 7, 5B, 5A)
  • Exceeds IECC 2009 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)
  • Exceeds Energy Star 2010 (Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window31 - 6248

Replace Window:

Before-Component After-Component Cost

Low-E, Triple, Non-metal, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (6B, 3B, 2A, 4C, 6A, 1A, 3C, 5C, 4B, 1B, 7, 1C, 2B, 5B, 4A, 5A, 2C, 3A, 6C, 8)
  • Exceeds IECC 2012 (8, 6B, 4A, 5B, 5A, 4C, 6A, 6C, 4B, 5C, 7)
  • Exceeds Energy Star 2010 (South-Central, North-Central, Southern, Northern)

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Air, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.21 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2009 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)
  • Exceeds IECC 2012 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window36 - 7255

Replace Window:

Before-Component After-Component Cost

Low-E, Triple, Non-metal, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (6B, 3B, 2A, 4C, 6A, 1A, 3C, 5C, 4B, 1B, 7, 1C, 2B, 5B, 4A, 5A, 2C, 3A, 6C, 8)
  • Exceeds IECC 2012 (8, 6B, 4A, 5B, 5A, 4C, 6A, 6C, 4B, 5C, 7)
  • Exceeds Energy Star 2010 (South-Central, North-Central, Southern, Northern)

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Air, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.19 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (North-Central, Southern, Northern, South-Central)
  • Exceeds IECC 2009 (6B, 6A, 3B, 2A, 4C, 1C, 2B, 5B, 4A, 1A, 3C, 5C, 4B, 1B, 7, 2C, 3A, 6C, 5A, 8)
  • Exceeds IECC 2012 (8, 6B, 7, 6A, 6C, 5A, 4C, 4A, 5B, 4B, 5C)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window37 - 7256

Replace Window:

Before-Component After-Component Cost

Low-E, Triple, Non-metal, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (6B, 3B, 2A, 4C, 6A, 1A, 3C, 5C, 4B, 1B, 7, 1C, 2B, 5B, 4A, 5A, 2C, 3A, 6C, 8)
  • Exceeds IECC 2012 (8, 6B, 4A, 5B, 5A, 4C, 6A, 6C, 4B, 5C, 7)
  • Exceeds Energy Star 2010 (South-Central, North-Central, Southern, Northern)

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.18 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (8, 6B, 5B, 4A, 5A, 4C, 6A, 6C, 5C, 4B, 7)
  • Exceeds IECC 2009 (8, 6B, 5B, 4A, 5A, 4C, 6A, 6C, 5C, 4B, 7)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window38 - 7457

Replace Window:

Before-Component After-Component Cost

Low-E, Triple, Non-metal, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (6B, 3B, 2A, 4C, 6A, 1A, 3C, 5C, 4B, 1B, 7, 1C, 2B, 5B, 4A, 5A, 2C, 3A, 6C, 8)
  • Exceeds IECC 2012 (8, 6B, 4A, 5B, 5A, 4C, 6A, 6C, 4B, 5C, 7)
  • Exceeds Energy Star 2010 (South-Central, North-Central, Southern, Northern)

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.17 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (Northern, North-Central, Southern, South-Central)
  • Exceeds IECC 2009 (6C, 5A, 2B, 5B, 4A, 1C, 1B, 7, 1A, 3C, 5C, 4B, 6A, 2A, 4C, 3B, 6B, 8, 2C, 3A)
  • Exceeds IECC 2012 (6C, 5A, 4A, 5B, 6B, 7, 4B, 5C, 8, 6A, 4C)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window38 - 7557

Replace Window:

Before-Component After-Component Cost

Low-E, Triple, Non-metal, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (6B, 3B, 2A, 4C, 6A, 1A, 3C, 5C, 4B, 1B, 7, 1C, 2B, 5B, 4A, 5A, 2C, 3A, 6C, 8)
  • Exceeds IECC 2012 (8, 6B, 4A, 5B, 5A, 4C, 6A, 6C, 4B, 5C, 7)
  • Exceeds Energy Star 2010 (South-Central, North-Central, Southern, Northern)

Lifetime:

  • 30 Years
 

Low-E, Triple, Non-metal, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (6B, 3B, 2A, 4C, 6A, 1A, 3C, 5C, 4B, 1B, 7, 1C, 2B, 5B, 4A, 5A, 2C, 3A, 6C, 8)
  • Exceeds IECC 2012 (8, 6B, 4A, 5B, 5A, 4C, 6A, 6C, 4B, 5C, 7)
  • Exceeds Energy Star 2010 (South-Central, North-Central, Southern, Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window31 - 6247

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Clear Storm

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.676
  • Storm Sash: clear
  • U-Value: 0.781 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Clear, Double, Metal, Air

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • Storm Sash:
  • U-Value: 0.76 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window21 - 4233

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Clear Storm

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.676
  • Storm Sash: clear
  • U-Value: 0.781 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Clear, Double, Non-metal, Air

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.49 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window21 - 4333

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Clear Storm

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.676
  • Storm Sash: clear
  • U-Value: 0.781 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Clear, Double, Thermal-Break, Air

Properties:

  • Film:
  • Frame Material: metal with thermal breaks
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.62
  • Storm Sash:
  • U-Value: 0.63 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window21 - 4233

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Clear Storm

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.676
  • Storm Sash: clear
  • U-Value: 0.781 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Air, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.32 Btu/h-ft^2-R

Performance Standards:

  • Meets IECC 2012 (5C, 6B, 7, 5B, 5A, 4C, 6A, 6C, 8)
  • Exceeds IECC 2009 (5C, 4B, 7, 5B, 4A, 5A, 4C, 6A, 6C, 8, 6B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window28 - 5744

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Clear Storm

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.676
  • Storm Sash: clear
  • U-Value: 0.781 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Air, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (8, 6B, 7, 6A, 6C, 5A, 4C, 4A, 5B, 4B, 5C)
  • Exceeds IECC 2009 (8, 6B, 7, 6A, 6C, 5A, 4C, 5B, 4A, 5C, 4B)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window30 - 6046

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Clear Storm

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.676
  • Storm Sash: clear
  • U-Value: 0.781 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Air, M-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (5B, 5C, 8, 6B, 7, 6A, 6C, 5A, 4C)
  • Exceeds IECC 2009 (8, 6B, 7, 6A, 6C, 5A, 4C, 5B, 4A, 5C, 4B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window29 - 5845

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Clear Storm

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.676
  • Storm Sash: clear
  • U-Value: 0.781 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (5C, 4B, 7, 5B, 4A, 5A, 4C, 6A, 6C, 8, 6B)
  • Exceeds IECC 2012 (5C, 6B, 7, 5B, 5A, 4C, 6A, 6C, 8)
  • Exceeds Energy Star 2010 (Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window30 - 6046

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Clear Storm

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.676
  • Storm Sash: clear
  • U-Value: 0.781 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.26 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2009 (6A, 4C, 5B, 4A, 5C, 8, 4B, 6B, 7, 6C, 5A)
  • Exceeds IECC 2012 (6A, 4C, 4A, 5B, 4B, 5C, 8, 6B, 7, 6C, 5A)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window32 - 6349

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Clear Storm

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.676
  • Storm Sash: clear
  • U-Value: 0.781 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Arg, M-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (4C, 6A, 6C, 5C, 8, 6B, 7, 5B, 5A)
  • Exceeds IECC 2009 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)
  • Exceeds Energy Star 2010 (Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window31 - 6248

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Clear Storm

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.676
  • Storm Sash: clear
  • U-Value: 0.781 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Non-metal, Air, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.39 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window21 - 4434

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Clear Storm

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.676
  • Storm Sash: clear
  • U-Value: 0.781 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Non-metal, Air, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (3B, 2C, 3A, 1B, 1A, 3C, 2B, 1C, 2A)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window23 - 4736

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Clear Storm

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.676
  • Storm Sash: clear
  • U-Value: 0.781 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Non-metal, Air, M-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.38 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window22 - 4535

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Clear Storm

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.676
  • Storm Sash: clear
  • U-Value: 0.781 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Non-metal, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window23 - 4736

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Clear Storm

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.676
  • Storm Sash: clear
  • U-Value: 0.781 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Non-metal, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.34 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (South-Central)
  • Exceeds IECC 2012 (4A, 4B)
  • Exceeds IECC 2009 (8, 6A, 4C, 2A, 3B, 5B, 4A, 2B, 1C, 7, 1B, 5C, 4B, 1A, 3C, 6C, 2C, 3A, 5A, 6B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window25 - 5039

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Clear Storm

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.676
  • Storm Sash: clear
  • U-Value: 0.781 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Non-metal, Arg, M-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.35 Btu/h-ft^2-R

Performance Standards:

  • Meets IECC 2009 (5C, 4B, 7, 5B, 4A, 5A, 4C, 6A, 6C, 8, 6B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window24 - 4938

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Clear Storm

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.676
  • Storm Sash: clear
  • U-Value: 0.781 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Air, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.21 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2009 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)
  • Exceeds IECC 2012 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window36 - 7255

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Clear Storm

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.676
  • Storm Sash: clear
  • U-Value: 0.781 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Air, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.19 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (North-Central, Southern, Northern, South-Central)
  • Exceeds IECC 2009 (6B, 6A, 3B, 2A, 4C, 1C, 2B, 5B, 4A, 1A, 3C, 5C, 4B, 1B, 7, 2C, 3A, 6C, 5A, 8)
  • Exceeds IECC 2012 (8, 6B, 7, 6A, 6C, 5A, 4C, 4A, 5B, 4B, 5C)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window37 - 7256

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Clear Storm

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.676
  • Storm Sash: clear
  • U-Value: 0.781 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.18 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (8, 6B, 5B, 4A, 5A, 4C, 6A, 6C, 5C, 4B, 7)
  • Exceeds IECC 2009 (8, 6B, 5B, 4A, 5A, 4C, 6A, 6C, 5C, 4B, 7)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window38 - 7457

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Clear Storm

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.676
  • Storm Sash: clear
  • U-Value: 0.781 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.17 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (Northern, North-Central, Southern, South-Central)
  • Exceeds IECC 2009 (6C, 5A, 2B, 5B, 4A, 1C, 1B, 7, 1A, 3C, 5C, 4B, 6A, 2A, 4C, 3B, 6B, 8, 2C, 3A)
  • Exceeds IECC 2012 (6C, 5A, 4A, 5B, 6B, 7, 4B, 5C, 8, 6A, 4C)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window38 - 7557

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Clear Storm

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.676
  • Storm Sash: clear
  • U-Value: 0.781 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Triple, Non-metal, Air, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (4C, 6A, 6C, 4B, 5C, 8, 6B, 7, 4A, 5B, 5A)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2009 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)
  • Exceeds Energy Star 2010 (North-Central)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window29 - 5945

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Clear Storm

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.676
  • Storm Sash: clear
  • U-Value: 0.781 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Triple, Non-metal, Air, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (South-Central, North-Central, Southern, Northern)
  • Exceeds IECC 2012 (4B, 5C, 7, 4A, 5B, 5A, 4C, 6A, 6C, 8, 6B)
  • Exceeds IECC 2009 (1A, 3C, 7, 4A, 5A, 2C, 3A, 6C, 8, 6B, 3B, 2A, 4C, 6A, 5C, 4B, 1B, 1C, 2B, 5B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window30 - 6046

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Clear Storm

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.676
  • Storm Sash: clear
  • U-Value: 0.781 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Triple, Non-metal, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (5B, 4A, 5C, 4B, 6B, 7, 6A, 6C, 5A, 4C, 8)
  • Exceeds IECC 2012 (4A, 5B, 4B, 5C, 6B, 7, 6A, 6C, 5A, 4C, 8)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window31 - 6147

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with Clear Storm

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.676
  • Storm Sash: clear
  • U-Value: 0.781 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Triple, Non-metal, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (6B, 3B, 2A, 4C, 6A, 1A, 3C, 5C, 4B, 1B, 7, 1C, 2B, 5B, 4A, 5A, 2C, 3A, 6C, 8)
  • Exceeds IECC 2012 (8, 6B, 4A, 5B, 5A, 4C, 6A, 6C, 4B, 5C, 7)
  • Exceeds Energy Star 2010 (South-Central, North-Central, Southern, Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window31 - 6247

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with High-Tvis Film

Properties:

  • Film: high t-vis
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.43
  • Storm Sash:
  • U-Value: 1.09 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Clear, Double, Metal, Air

Properties:

  • Film:
  • Frame Material: metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.67
  • Storm Sash:
  • U-Value: 0.76 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window21 - 4233

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with High-Tvis Film

Properties:

  • Film: high t-vis
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.43
  • Storm Sash:
  • U-Value: 1.09 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Clear, Double, Non-metal, Air

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.49 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window21 - 4333

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with High-Tvis Film

Properties:

  • Film: high t-vis
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.43
  • Storm Sash:
  • U-Value: 1.09 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Clear, Double, Thermal-Break, Air

Properties:

  • Film:
  • Frame Material: metal with thermal breaks
  • Gas Fill: air
  • Glazing Type: clear
  • Panes: 2
  • SHGC: 0.62
  • Storm Sash:
  • U-Value: 0.63 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window21 - 4233

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with High-Tvis Film

Properties:

  • Film: high t-vis
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.43
  • Storm Sash:
  • U-Value: 1.09 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Air, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.32 Btu/h-ft^2-R

Performance Standards:

  • Meets IECC 2012 (5C, 6B, 7, 5B, 5A, 4C, 6A, 6C, 8)
  • Exceeds IECC 2009 (5C, 4B, 7, 5B, 4A, 5A, 4C, 6A, 6C, 8, 6B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window28 - 5744

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with High-Tvis Film

Properties:

  • Film: high t-vis
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.43
  • Storm Sash:
  • U-Value: 1.09 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Air, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (8, 6B, 7, 6A, 6C, 5A, 4C, 4A, 5B, 4B, 5C)
  • Exceeds IECC 2009 (8, 6B, 7, 6A, 6C, 5A, 4C, 5B, 4A, 5C, 4B)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window30 - 6046

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with High-Tvis Film

Properties:

  • Film: high t-vis
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.43
  • Storm Sash:
  • U-Value: 1.09 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Air, M-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2012 (5B, 5C, 8, 6B, 7, 6A, 6C, 5A, 4C)
  • Exceeds IECC 2009 (8, 6B, 7, 6A, 6C, 5A, 4C, 5B, 4A, 5C, 4B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window29 - 5845

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with High-Tvis Film

Properties:

  • Film: high t-vis
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.43
  • Storm Sash:
  • U-Value: 1.09 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.56
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (5C, 4B, 7, 5B, 4A, 5A, 4C, 6A, 6C, 8, 6B)
  • Exceeds IECC 2012 (5C, 6B, 7, 5B, 5A, 4C, 6A, 6C, 8)
  • Exceeds Energy Star 2010 (Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window30 - 6046

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with High-Tvis Film

Properties:

  • Film: high t-vis
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.43
  • Storm Sash:
  • U-Value: 1.09 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.31
  • Storm Sash:
  • U-Value: 0.26 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2009 (6A, 4C, 5B, 4A, 5C, 8, 4B, 6B, 7, 6C, 5A)
  • Exceeds IECC 2012 (6A, 4C, 4A, 5B, 4B, 5C, 8, 6B, 7, 6C, 5A)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window32 - 6349

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with High-Tvis Film

Properties:

  • Film: high t-vis
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.43
  • Storm Sash:
  • U-Value: 1.09 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Insulated, Arg, M-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.46
  • Storm Sash:
  • U-Value: 0.27 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (4C, 6A, 6C, 5C, 8, 6B, 7, 5B, 5A)
  • Exceeds IECC 2009 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)
  • Exceeds Energy Star 2010 (Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window31 - 6248

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with High-Tvis Film

Properties:

  • Film: high t-vis
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.43
  • Storm Sash:
  • U-Value: 1.09 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Non-metal, Air, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.39 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window21 - 4434

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with High-Tvis Film

Properties:

  • Film: high t-vis
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.43
  • Storm Sash:
  • U-Value: 1.09 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Non-metal, Air, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2009 (3B, 2C, 3A, 1B, 1A, 3C, 2B, 1C, 2A)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window23 - 4736

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with High-Tvis Film

Properties:

  • Film: high t-vis
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.43
  • Storm Sash:
  • U-Value: 1.09 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Non-metal, Air, M-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.38 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window22 - 4535

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with High-Tvis Film

Properties:

  • Film: high t-vis
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.43
  • Storm Sash:
  • U-Value: 1.09 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Non-metal, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 2
  • SHGC: 0.53
  • Storm Sash:
  • U-Value: 0.37 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window23 - 4736

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with High-Tvis Film

Properties:

  • Film: high t-vis
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.43
  • Storm Sash:
  • U-Value: 1.09 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Non-metal, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 2
  • SHGC: 0.3
  • Storm Sash:
  • U-Value: 0.34 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (South-Central)
  • Exceeds IECC 2012 (4A, 4B)
  • Exceeds IECC 2009 (8, 6A, 4C, 2A, 3B, 5B, 4A, 2B, 1C, 7, 1B, 5C, 4B, 1A, 3C, 6C, 2C, 3A, 5A, 6B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window25 - 5039

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with High-Tvis Film

Properties:

  • Film: high t-vis
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.43
  • Storm Sash:
  • U-Value: 1.09 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Double, Non-metal, Arg, M-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: argon
  • Glazing Type: medium-gain low-e
  • Panes: 2
  • SHGC: 0.44
  • Storm Sash:
  • U-Value: 0.35 Btu/h-ft^2-R

Performance Standards:

  • Meets IECC 2009 (5C, 4B, 7, 5B, 4A, 5A, 4C, 6A, 6C, 8, 6B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window24 - 4938

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with High-Tvis Film

Properties:

  • Film: high t-vis
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.43
  • Storm Sash:
  • U-Value: 1.09 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Air, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.21 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (North-Central, Northern)
  • Exceeds IECC 2009 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)
  • Exceeds IECC 2012 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window36 - 7255

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with High-Tvis Film

Properties:

  • Film: high t-vis
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.43
  • Storm Sash:
  • U-Value: 1.09 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Air, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.19 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (North-Central, Southern, Northern, South-Central)
  • Exceeds IECC 2009 (6B, 6A, 3B, 2A, 4C, 1C, 2B, 5B, 4A, 1A, 3C, 5C, 4B, 1B, 7, 2C, 3A, 6C, 5A, 8)
  • Exceeds IECC 2012 (8, 6B, 7, 6A, 6C, 5A, 4C, 4A, 5B, 4B, 5C)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window37 - 7256

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with High-Tvis Film

Properties:

  • Film: high t-vis
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.43
  • Storm Sash:
  • U-Value: 1.09 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Arg, H-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.4
  • Storm Sash:
  • U-Value: 0.18 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (8, 6B, 5B, 4A, 5A, 4C, 6A, 6C, 5C, 4B, 7)
  • Exceeds IECC 2009 (8, 6B, 5B, 4A, 5A, 4C, 6A, 6C, 5C, 4B, 7)
  • Exceeds Energy Star 2010 (North-Central, Northern)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window38 - 7457

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with High-Tvis Film

Properties:

  • Film: high t-vis
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.43
  • Storm Sash:
  • U-Value: 1.09 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Triple, Insulated, Arg, L-Gain

Properties:

  • Film:
  • Frame Material: insulated
  • Gas Fill: argon
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.27
  • Storm Sash:
  • U-Value: 0.17 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (Northern, North-Central, Southern, South-Central)
  • Exceeds IECC 2009 (6C, 5A, 2B, 5B, 4A, 1C, 1B, 7, 1A, 3C, 5C, 4B, 6A, 2A, 4C, 3B, 6B, 8, 2C, 3A)
  • Exceeds IECC 2012 (6C, 5A, 4A, 5B, 6B, 7, 4B, 5C, 8, 6A, 4C)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window38 - 7557

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with High-Tvis Film

Properties:

  • Film: high t-vis
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.43
  • Storm Sash:
  • U-Value: 1.09 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Triple, Non-metal, Air, H-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: high-gain low-e
  • Panes: 3
  • SHGC: 0.38
  • Storm Sash:
  • U-Value: 0.3 Btu/h-ft^2-R

Performance Standards:

  • Exceeds IECC 2012 (4C, 6A, 6C, 4B, 5C, 8, 6B, 7, 4A, 5B, 5A)
  • Meets Energy Star 2010 (Northern)
  • Exceeds IECC 2009 (4C, 6A, 6C, 5C, 8, 4B, 6B, 7, 5B, 4A, 5A)
  • Exceeds Energy Star 2010 (North-Central)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window29 - 5945

Replace Window:

Before-Component After-Component Cost

Single-Pane, Clear, Metal Frame, with High-Tvis Film

Properties:

  • Film: high t-vis
  • Frame Material: metal
  • Gas Fill:
  • Glazing Type: clear
  • Panes: 1
  • SHGC: 0.43
  • Storm Sash:
  • U-Value: 1.09 Btu/h-ft^2-R

Lifetime:

  • 30 Years
 

Low-E, Triple, Non-metal, Air, L-Gain

Properties:

  • Film:
  • Frame Material: non-metal
  • Gas Fill: air
  • Glazing Type: low-gain low-e
  • Panes: 3
  • SHGC: 0.26
  • Storm Sash:
  • U-Value: 0.29 Btu/h-ft^2-R

Performance Standards:

  • Exceeds Energy Star 2010 (South-Central, North-Central, Southern, Northern)
  • Exceeds IECC 2012 (4B, 5C, 7, 4A, 5B, 5A, 4C, 6A, 6C, 8, 6B)
  • Exceeds IECC 2009 (1A, 3C, 7, 4A, 5A, 2C, 3A, 6C, 8, 6B, 3B, 2A, 4C, 6A, 5C, 4B, 1B, 1C, 2B, 5B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Window30 - 6046

Replace Window:

Before-Component After-Component Cost