Skip to content National Residential Efficiency Measures Database National Renewable Energy Laboratory

Submit Questions/Comments

Retrofit Measures for Doors

Here you will find the data for Doors measures available in the National Residential Efficiency Measures Database. Each measure consists of a before-component, an after-component, and the estimated cost to implement the measure. The measures are listed alphabetically based upon the name of the before-component. Where multiple costs are indicated they must be combined to obtain total measure cost (e.g., fixed ($) and normalized ($/sf) costs).

Cost Drivers

There are many factors that influence the ultimate cost of Doors measures. The application of the average measure costs displayed below to any particular home is discouraged. Examples of the kinds of issues that can influence the cost of Doors measures include:
  • Prevailing local wages
  • Drive time
  • Local code requirements
  • Existing construction and materials
  • Presence of hazardous materials

Viewing 35 Doors Measure(s) of 35

Replace Swinging Entry Door:

Before-Component After-Component Cost

Fiberglass

Properties:

  • Door Type: opaque
  • Glazing Fraction: 0.0
  • Material: fiberglass
  • Operation: swinging
  • SHGC: 0.0
  • U-Value: 0.2 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2012 (6B, 8, 6A, 2A, 4C, 3B, 2B, 4A, 5B, 7, 3C, 4B, 5C, 2C, 3A, 6C, 5A)
  • Exceeds IECC 2009 (6B, 6A, 2A, 4C, 3B, 2B, 4A, 5B, 1C, 1B, 7, 1A, 3C, 4B, 5C, 2C, 3A, 6C, 5A, 8)

Lifetime:

  • 30 Years
 

Fiberglass

Properties:

  • Door Type: opaque
  • Glazing Fraction: 0.0
  • Material: fiberglass
  • Operation: swinging
  • SHGC: 0.0
  • U-Value: 0.2 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2012 (6B, 8, 6A, 2A, 4C, 3B, 2B, 4A, 5B, 7, 3C, 4B, 5C, 2C, 3A, 6C, 5A)
  • Exceeds IECC 2009 (6B, 6A, 2A, 4C, 3B, 2B, 4A, 5B, 1C, 1B, 7, 1A, 3C, 4B, 5C, 2C, 3A, 6C, 5A, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Door8.4 - 1814

Replace Swinging Entry Door:

Before-Component After-Component Cost

Fiberglass

Properties:

  • Door Type: opaque
  • Glazing Fraction: 0.0
  • Material: fiberglass
  • Operation: swinging
  • SHGC: 0.0
  • U-Value: 0.2 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2012 (6B, 8, 6A, 2A, 4C, 3B, 2B, 4A, 5B, 7, 3C, 4B, 5C, 2C, 3A, 6C, 5A)
  • Exceeds IECC 2009 (6B, 6A, 2A, 4C, 3B, 2B, 4A, 5B, 1C, 1B, 7, 1A, 3C, 4B, 5C, 2C, 3A, 6C, 5A, 8)

Lifetime:

  • 30 Years
 

Steel

Properties:

  • Door Type: opaque
  • Glazing Fraction: 0.0
  • Material: steel
  • Operation: swinging
  • SHGC: 0.0
  • U-Value: 0.2 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (6B, 3B, 2A, 4C, 6A, 1A, 3C, 4B, 5C, 1B, 7, 1C, 2B, 5B, 4A, 5A, 2C, 6C, 3A, 8)
  • Exceeds IECC 2012 (6B, 3B, 4C, 2A, 6A, 4B, 3C, 5C, 7, 5B, 2B, 4A, 5A, 6C, 2C, 3A, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Door5.8 - 139.7

Replace Swinging Entry Door:

Before-Component After-Component Cost

Fiberglass, <=1/2-Lite Glazing

Properties:

  • Door Type: <=1/2-lite
  • Glazing Fraction: 0.29
  • Material: fiberglass
  • Operation: swinging
  • SHGC: 0.26
  • U-Value: 0.41 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1C, 1B, 1A, 3C, 2C, 3A, 2A, 3B, 2B)

Lifetime:

  • 30 Years
 

Fiberglass

Properties:

  • Door Type: opaque
  • Glazing Fraction: 0.0
  • Material: fiberglass
  • Operation: swinging
  • SHGC: 0.0
  • U-Value: 0.2 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2012 (6B, 8, 6A, 2A, 4C, 3B, 2B, 4A, 5B, 7, 3C, 4B, 5C, 2C, 3A, 6C, 5A)
  • Exceeds IECC 2009 (6B, 6A, 2A, 4C, 3B, 2B, 4A, 5B, 1C, 1B, 7, 1A, 3C, 4B, 5C, 2C, 3A, 6C, 5A, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Door8.4 - 1814

Replace Swinging Entry Door:

Before-Component After-Component Cost

Fiberglass, <=1/2-Lite Glazing

Properties:

  • Door Type: <=1/2-lite
  • Glazing Fraction: 0.29
  • Material: fiberglass
  • Operation: swinging
  • SHGC: 0.22
  • U-Value: 0.26 Btu/h-R-ft^2

Performance Standards:

  • Exceeds Energy Star 2010
  • Exceeds IECC 2012 (8, 6B, 6A, 3B, 2A, 4C, 2B, 4A, 5B, 3C, 4B, 5C, 7, 2C, 3A, 6C, 5A)
  • Exceeds IECC 2009 (8, 6A, 3B, 2A, 4C, 1C, 2B, 4A, 5B, 1A, 3C, 4B, 5C, 1B, 7, 2C, 3A, 6C, 5A, 6B)

Lifetime:

  • 30 Years
 

Fiberglass

Properties:

  • Door Type: opaque
  • Glazing Fraction: 0.0
  • Material: fiberglass
  • Operation: swinging
  • SHGC: 0.0
  • U-Value: 0.2 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2012 (6B, 8, 6A, 2A, 4C, 3B, 2B, 4A, 5B, 7, 3C, 4B, 5C, 2C, 3A, 6C, 5A)
  • Exceeds IECC 2009 (6B, 6A, 2A, 4C, 3B, 2B, 4A, 5B, 1C, 1B, 7, 1A, 3C, 4B, 5C, 2C, 3A, 6C, 5A, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Door8.4 - 1814

Replace Swinging Entry Door:

Before-Component After-Component Cost

Fiberglass, <=1/2-Lite Glazing

Properties:

  • Door Type: <=1/2-lite
  • Glazing Fraction: 0.29
  • Material: fiberglass
  • Operation: swinging
  • SHGC: 0.26
  • U-Value: 0.41 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1C, 1B, 1A, 3C, 2C, 3A, 2A, 3B, 2B)

Lifetime:

  • 30 Years
 

Fiberglass, <=1/2-Lite Glazing

Properties:

  • Door Type: <=1/2-lite
  • Glazing Fraction: 0.29
  • Material: fiberglass
  • Operation: swinging
  • SHGC: 0.26
  • U-Value: 0.41 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1C, 1B, 1A, 3C, 2C, 3A, 2A, 3B, 2B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Door6.8 - 1511

Replace Swinging Entry Door:

Before-Component After-Component Cost

Fiberglass, <=1/2-Lite Glazing

Properties:

  • Door Type: <=1/2-lite
  • Glazing Fraction: 0.29
  • Material: fiberglass
  • Operation: swinging
  • SHGC: 0.26
  • U-Value: 0.41 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1C, 1B, 1A, 3C, 2C, 3A, 2A, 3B, 2B)

Lifetime:

  • 30 Years
 

Fiberglass, <=1/2-Lite Glazing

Properties:

  • Door Type: <=1/2-lite
  • Glazing Fraction: 0.29
  • Material: fiberglass
  • Operation: swinging
  • SHGC: 0.22
  • U-Value: 0.26 Btu/h-R-ft^2

Performance Standards:

  • Exceeds Energy Star 2010
  • Exceeds IECC 2012 (8, 6B, 6A, 3B, 2A, 4C, 2B, 4A, 5B, 3C, 4B, 5C, 7, 2C, 3A, 6C, 5A)
  • Exceeds IECC 2009 (8, 6A, 3B, 2A, 4C, 1C, 2B, 4A, 5B, 1A, 3C, 4B, 5C, 1B, 7, 2C, 3A, 6C, 5A, 6B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Door7 - 1512

Replace Swinging Entry Door:

Before-Component After-Component Cost

Fiberglass, <=1/2-Lite Glazing

Properties:

  • Door Type: <=1/2-lite
  • Glazing Fraction: 0.29
  • Material: fiberglass
  • Operation: swinging
  • SHGC: 0.22
  • U-Value: 0.26 Btu/h-R-ft^2

Performance Standards:

  • Exceeds Energy Star 2010
  • Exceeds IECC 2012 (8, 6B, 6A, 3B, 2A, 4C, 2B, 4A, 5B, 3C, 4B, 5C, 7, 2C, 3A, 6C, 5A)
  • Exceeds IECC 2009 (8, 6A, 3B, 2A, 4C, 1C, 2B, 4A, 5B, 1A, 3C, 4B, 5C, 1B, 7, 2C, 3A, 6C, 5A, 6B)

Lifetime:

  • 30 Years
 

Fiberglass, <=1/2-Lite Glazing

Properties:

  • Door Type: <=1/2-lite
  • Glazing Fraction: 0.29
  • Material: fiberglass
  • Operation: swinging
  • SHGC: 0.22
  • U-Value: 0.26 Btu/h-R-ft^2

Performance Standards:

  • Exceeds Energy Star 2010
  • Exceeds IECC 2012 (8, 6B, 6A, 3B, 2A, 4C, 2B, 4A, 5B, 3C, 4B, 5C, 7, 2C, 3A, 6C, 5A)
  • Exceeds IECC 2009 (8, 6A, 3B, 2A, 4C, 1C, 2B, 4A, 5B, 1A, 3C, 4B, 5C, 1B, 7, 2C, 3A, 6C, 5A, 6B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Door7 - 1512

Replace Swinging Entry Door:

Before-Component After-Component Cost

Fiberglass, <=1/2-Lite Glazing

Properties:

  • Door Type: <=1/2-lite
  • Glazing Fraction: 0.29
  • Material: fiberglass
  • Operation: swinging
  • SHGC: 0.26
  • U-Value: 0.41 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1C, 1B, 1A, 3C, 2C, 3A, 2A, 3B, 2B)

Lifetime:

  • 30 Years
 

Fiberglass, >1/2-Lite Glazing

Properties:

  • Door Type: >1/2-lite
  • Glazing Fraction: 0.44
  • Material: fiberglass
  • Operation: swinging
  • SHGC: 0.3
  • U-Value: 0.32 Btu/h-R-ft^2

Performance Standards:

  • Meets IECC 2012 (7, 8, 5C, 5B, 4C, 5A, 6A, 6C, 6B)
  • Meets Energy Star 2010
  • Exceeds IECC 2012 (4A, 4B)
  • Exceeds IECC 2009 (7, 4B, 5C, 4A, 5B, 4C, 5A, 6A, 6C, 6B, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Door7.1 - 1512

Replace Swinging Entry Door:

Before-Component After-Component Cost

Fiberglass, <=1/2-Lite Glazing

Properties:

  • Door Type: <=1/2-lite
  • Glazing Fraction: 0.29
  • Material: fiberglass
  • Operation: swinging
  • SHGC: 0.26
  • U-Value: 0.41 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1C, 1B, 1A, 3C, 2C, 3A, 2A, 3B, 2B)

Lifetime:

  • 30 Years
 

Steel

Properties:

  • Door Type: opaque
  • Glazing Fraction: 0.0
  • Material: steel
  • Operation: swinging
  • SHGC: 0.0
  • U-Value: 0.2 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (6B, 3B, 2A, 4C, 6A, 1A, 3C, 4B, 5C, 1B, 7, 1C, 2B, 5B, 4A, 5A, 2C, 6C, 3A, 8)
  • Exceeds IECC 2012 (6B, 3B, 4C, 2A, 6A, 4B, 3C, 5C, 7, 5B, 2B, 4A, 5A, 6C, 2C, 3A, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Door5.8 - 139.7

Replace Swinging Entry Door:

Before-Component After-Component Cost

Fiberglass, <=1/2-Lite Glazing

Properties:

  • Door Type: <=1/2-lite
  • Glazing Fraction: 0.29
  • Material: fiberglass
  • Operation: swinging
  • SHGC: 0.22
  • U-Value: 0.26 Btu/h-R-ft^2

Performance Standards:

  • Exceeds Energy Star 2010
  • Exceeds IECC 2012 (8, 6B, 6A, 3B, 2A, 4C, 2B, 4A, 5B, 3C, 4B, 5C, 7, 2C, 3A, 6C, 5A)
  • Exceeds IECC 2009 (8, 6A, 3B, 2A, 4C, 1C, 2B, 4A, 5B, 1A, 3C, 4B, 5C, 1B, 7, 2C, 3A, 6C, 5A, 6B)

Lifetime:

  • 30 Years
 

Steel

Properties:

  • Door Type: opaque
  • Glazing Fraction: 0.0
  • Material: steel
  • Operation: swinging
  • SHGC: 0.0
  • U-Value: 0.2 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (6B, 3B, 2A, 4C, 6A, 1A, 3C, 4B, 5C, 1B, 7, 1C, 2B, 5B, 4A, 5A, 2C, 6C, 3A, 8)
  • Exceeds IECC 2012 (6B, 3B, 4C, 2A, 6A, 4B, 3C, 5C, 7, 5B, 2B, 4A, 5A, 6C, 2C, 3A, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Door5.8 - 139.7

Replace Swinging Entry Door:

Before-Component After-Component Cost

Fiberglass, >1/2-Lite Glazing

Properties:

  • Door Type: >1/2-lite
  • Glazing Fraction: 0.44
  • Material: fiberglass
  • Operation: swinging
  • SHGC: 0.3
  • U-Value: 0.32 Btu/h-R-ft^2

Performance Standards:

  • Meets IECC 2012 (7, 8, 5C, 5B, 4C, 5A, 6A, 6C, 6B)
  • Meets Energy Star 2010
  • Exceeds IECC 2012 (4A, 4B)
  • Exceeds IECC 2009 (7, 4B, 5C, 4A, 5B, 4C, 5A, 6A, 6C, 6B, 8)

Lifetime:

  • 30 Years
 

Fiberglass

Properties:

  • Door Type: opaque
  • Glazing Fraction: 0.0
  • Material: fiberglass
  • Operation: swinging
  • SHGC: 0.0
  • U-Value: 0.2 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2012 (6B, 8, 6A, 2A, 4C, 3B, 2B, 4A, 5B, 7, 3C, 4B, 5C, 2C, 3A, 6C, 5A)
  • Exceeds IECC 2009 (6B, 6A, 2A, 4C, 3B, 2B, 4A, 5B, 1C, 1B, 7, 1A, 3C, 4B, 5C, 2C, 3A, 6C, 5A, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Door8.4 - 1814

Replace Swinging Entry Door:

Before-Component After-Component Cost

Fiberglass, >1/2-Lite Glazing

Properties:

  • Door Type: >1/2-lite
  • Glazing Fraction: 0.44
  • Material: fiberglass
  • Operation: swinging
  • SHGC: 0.3
  • U-Value: 0.32 Btu/h-R-ft^2

Performance Standards:

  • Meets IECC 2012 (7, 8, 5C, 5B, 4C, 5A, 6A, 6C, 6B)
  • Meets Energy Star 2010
  • Exceeds IECC 2012 (4A, 4B)
  • Exceeds IECC 2009 (7, 4B, 5C, 4A, 5B, 4C, 5A, 6A, 6C, 6B, 8)

Lifetime:

  • 30 Years
 

Fiberglass, <=1/2-Lite Glazing

Properties:

  • Door Type: <=1/2-lite
  • Glazing Fraction: 0.29
  • Material: fiberglass
  • Operation: swinging
  • SHGC: 0.22
  • U-Value: 0.26 Btu/h-R-ft^2

Performance Standards:

  • Exceeds Energy Star 2010
  • Exceeds IECC 2012 (8, 6B, 6A, 3B, 2A, 4C, 2B, 4A, 5B, 3C, 4B, 5C, 7, 2C, 3A, 6C, 5A)
  • Exceeds IECC 2009 (8, 6A, 3B, 2A, 4C, 1C, 2B, 4A, 5B, 1A, 3C, 4B, 5C, 1B, 7, 2C, 3A, 6C, 5A, 6B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Door7 - 1512

Replace Swinging Entry Door:

Before-Component After-Component Cost

Fiberglass, >1/2-Lite Glazing

Properties:

  • Door Type: >1/2-lite
  • Glazing Fraction: 0.44
  • Material: fiberglass
  • Operation: swinging
  • SHGC: 0.3
  • U-Value: 0.32 Btu/h-R-ft^2

Performance Standards:

  • Meets IECC 2012 (7, 8, 5C, 5B, 4C, 5A, 6A, 6C, 6B)
  • Meets Energy Star 2010
  • Exceeds IECC 2012 (4A, 4B)
  • Exceeds IECC 2009 (7, 4B, 5C, 4A, 5B, 4C, 5A, 6A, 6C, 6B, 8)

Lifetime:

  • 30 Years
 

Fiberglass, >1/2-Lite Glazing

Properties:

  • Door Type: >1/2-lite
  • Glazing Fraction: 0.44
  • Material: fiberglass
  • Operation: swinging
  • SHGC: 0.3
  • U-Value: 0.32 Btu/h-R-ft^2

Performance Standards:

  • Meets IECC 2012 (7, 8, 5C, 5B, 4C, 5A, 6A, 6C, 6B)
  • Meets Energy Star 2010
  • Exceeds IECC 2012 (4A, 4B)
  • Exceeds IECC 2009 (7, 4B, 5C, 4A, 5B, 4C, 5A, 6A, 6C, 6B, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Door7.1 - 1512

Replace Swinging Entry Door:

Before-Component After-Component Cost

Fiberglass, >1/2-Lite Glazing

Properties:

  • Door Type: >1/2-lite
  • Glazing Fraction: 0.44
  • Material: fiberglass
  • Operation: swinging
  • SHGC: 0.3
  • U-Value: 0.32 Btu/h-R-ft^2

Performance Standards:

  • Meets IECC 2012 (7, 8, 5C, 5B, 4C, 5A, 6A, 6C, 6B)
  • Meets Energy Star 2010
  • Exceeds IECC 2012 (4A, 4B)
  • Exceeds IECC 2009 (7, 4B, 5C, 4A, 5B, 4C, 5A, 6A, 6C, 6B, 8)

Lifetime:

  • 30 Years
 

Steel

Properties:

  • Door Type: opaque
  • Glazing Fraction: 0.0
  • Material: steel
  • Operation: swinging
  • SHGC: 0.0
  • U-Value: 0.2 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (6B, 3B, 2A, 4C, 6A, 1A, 3C, 4B, 5C, 1B, 7, 1C, 2B, 5B, 4A, 5A, 2C, 6C, 3A, 8)
  • Exceeds IECC 2012 (6B, 3B, 4C, 2A, 6A, 4B, 3C, 5C, 7, 5B, 2B, 4A, 5A, 6C, 2C, 3A, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Door5.8 - 139.7

Replace Sliding Entry Door:

Before-Component After-Component Cost

Sliding, Fiberglass, >1/2-Lite Glazing

Properties:

  • Door Type: >1/2-lite
  • Glazing Fraction: 0.7
  • Material: fiberglass
  • Operation: sliding
  • SHGC: 0.3
  • U-Value: 0.32 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (6A, 4C, 4A, 5B, 4B, 5C, 8, 6B, 7, 6C, 5A)
  • Meets Energy Star 2010
  • Exceeds IECC 2012 (4B, 4A)
  • Meets IECC 2012 (6A, 6C, 5A, 4C, 5B, 8, 5C, 6B, 7)

Lifetime:

  • 30 Years
 

Sliding, Fiberglass, >1/2-Lite Glazing

Properties:

  • Door Type: >1/2-lite
  • Glazing Fraction: 0.7
  • Material: fiberglass
  • Operation: sliding
  • SHGC: 0.3
  • U-Value: 0.32 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (6A, 4C, 4A, 5B, 4B, 5C, 8, 6B, 7, 6C, 5A)
  • Meets Energy Star 2010
  • Exceeds IECC 2012 (4B, 4A)
  • Meets IECC 2012 (6A, 6C, 5A, 4C, 5B, 8, 5C, 6B, 7)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Door11 - 2519

Replace Sliding Entry Door:

Before-Component After-Component Cost

Sliding, Vinyl, >1/2-Lite Glazing

Properties:

  • Door Type: >1/2-lite
  • Glazing Fraction: 0.7
  • Material: vinyl
  • Operation: sliding
  • SHGC: 0.53
  • U-Value: 0.5 Btu/h-R-ft^2

Lifetime:

  • 30 Years
 

Sliding, Fiberglass, >1/2-Lite Glazing

Properties:

  • Door Type: >1/2-lite
  • Glazing Fraction: 0.7
  • Material: fiberglass
  • Operation: sliding
  • SHGC: 0.3
  • U-Value: 0.32 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (6A, 4C, 4A, 5B, 4B, 5C, 8, 6B, 7, 6C, 5A)
  • Meets Energy Star 2010
  • Exceeds IECC 2012 (4B, 4A)
  • Meets IECC 2012 (6A, 6C, 5A, 4C, 5B, 8, 5C, 6B, 7)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Door11 - 2519

Replace Sliding Entry Door:

Before-Component After-Component Cost

Sliding, Vinyl, >1/2-Lite Glazing

Properties:

  • Door Type: >1/2-lite
  • Glazing Fraction: 0.7
  • Material: vinyl
  • Operation: sliding
  • SHGC: 0.53
  • U-Value: 0.5 Btu/h-R-ft^2

Lifetime:

  • 30 Years
 

Sliding, Vinyl, >1/2-Lite Glazing

Properties:

  • Door Type: >1/2-lite
  • Glazing Fraction: 0.7
  • Material: vinyl
  • Operation: sliding
  • SHGC: 0.53
  • U-Value: 0.5 Btu/h-R-ft^2

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Door10 - 2217

Replace Sliding Entry Door:

Before-Component After-Component Cost

Sliding, Wood, >1/2-Lite Glazing

Properties:

  • Door Type: >1/2-lite
  • Glazing Fraction: 0.7
  • Material: wood
  • Operation: sliding
  • SHGC: 0.86
  • U-Value: 1.08 Btu/h-R-ft^2

Lifetime:

  • 30 Years
 

Sliding, Fiberglass, >1/2-Lite Glazing

Properties:

  • Door Type: >1/2-lite
  • Glazing Fraction: 0.7
  • Material: fiberglass
  • Operation: sliding
  • SHGC: 0.3
  • U-Value: 0.32 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (6A, 4C, 4A, 5B, 4B, 5C, 8, 6B, 7, 6C, 5A)
  • Meets Energy Star 2010
  • Exceeds IECC 2012 (4B, 4A)
  • Meets IECC 2012 (6A, 6C, 5A, 4C, 5B, 8, 5C, 6B, 7)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Door11 - 2519

Replace Sliding Entry Door:

Before-Component After-Component Cost

Sliding, Wood, >1/2-Lite Glazing

Properties:

  • Door Type: >1/2-lite
  • Glazing Fraction: 0.7
  • Material: wood
  • Operation: sliding
  • SHGC: 0.86
  • U-Value: 1.08 Btu/h-R-ft^2

Lifetime:

  • 30 Years
 

Sliding, Vinyl, >1/2-Lite Glazing

Properties:

  • Door Type: >1/2-lite
  • Glazing Fraction: 0.7
  • Material: vinyl
  • Operation: sliding
  • SHGC: 0.53
  • U-Value: 0.5 Btu/h-R-ft^2

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Door10 - 2217

Replace Sliding Entry Door:

Before-Component After-Component Cost

Sliding, Wood, >1/2-Lite Glazing

Properties:

  • Door Type: >1/2-lite
  • Glazing Fraction: 0.7
  • Material: wood
  • Operation: sliding
  • SHGC: 0.86
  • U-Value: 1.08 Btu/h-R-ft^2

Lifetime:

  • 30 Years
 

Sliding, Wood, >1/2-Lite Glazing

Properties:

  • Door Type: >1/2-lite
  • Glazing Fraction: 0.7
  • Material: wood
  • Operation: sliding
  • SHGC: 0.86
  • U-Value: 1.08 Btu/h-R-ft^2

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Door8.9 - 1915

Replace Swinging Entry Door:

Before-Component After-Component Cost

Steel

Properties:

  • Door Type: opaque
  • Glazing Fraction: 0.0
  • Material: steel
  • Operation: swinging
  • SHGC: 0.0
  • U-Value: 0.2 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (6B, 3B, 2A, 4C, 6A, 1A, 3C, 4B, 5C, 1B, 7, 1C, 2B, 5B, 4A, 5A, 2C, 6C, 3A, 8)
  • Exceeds IECC 2012 (6B, 3B, 4C, 2A, 6A, 4B, 3C, 5C, 7, 5B, 2B, 4A, 5A, 6C, 2C, 3A, 8)

Lifetime:

  • 30 Years
 

Fiberglass

Properties:

  • Door Type: opaque
  • Glazing Fraction: 0.0
  • Material: fiberglass
  • Operation: swinging
  • SHGC: 0.0
  • U-Value: 0.2 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2012 (6B, 8, 6A, 2A, 4C, 3B, 2B, 4A, 5B, 7, 3C, 4B, 5C, 2C, 3A, 6C, 5A)
  • Exceeds IECC 2009 (6B, 6A, 2A, 4C, 3B, 2B, 4A, 5B, 1C, 1B, 7, 1A, 3C, 4B, 5C, 2C, 3A, 6C, 5A, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Door8.4 - 1814

Replace Swinging Entry Door:

Before-Component After-Component Cost

Steel

Properties:

  • Door Type: opaque
  • Glazing Fraction: 0.0
  • Material: steel
  • Operation: swinging
  • SHGC: 0.0
  • U-Value: 0.2 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (6B, 3B, 2A, 4C, 6A, 1A, 3C, 4B, 5C, 1B, 7, 1C, 2B, 5B, 4A, 5A, 2C, 6C, 3A, 8)
  • Exceeds IECC 2012 (6B, 3B, 4C, 2A, 6A, 4B, 3C, 5C, 7, 5B, 2B, 4A, 5A, 6C, 2C, 3A, 8)

Lifetime:

  • 30 Years
 

Steel

Properties:

  • Door Type: opaque
  • Glazing Fraction: 0.0
  • Material: steel
  • Operation: swinging
  • SHGC: 0.0
  • U-Value: 0.2 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (6B, 3B, 2A, 4C, 6A, 1A, 3C, 4B, 5C, 1B, 7, 1C, 2B, 5B, 4A, 5A, 2C, 6C, 3A, 8)
  • Exceeds IECC 2012 (6B, 3B, 4C, 2A, 6A, 4B, 3C, 5C, 7, 5B, 2B, 4A, 5A, 6C, 2C, 3A, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Door5.8 - 139.7

Replace Swinging Entry Door:

Before-Component After-Component Cost

Steel, <=1/2-Lite Glazing

Properties:

  • Door Type: <=1/2-lite
  • Glazing Fraction: 0.29
  • Material: steel
  • Operation: swinging
  • SHGC: 0.22
  • U-Value: 0.66 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C)

Lifetime:

  • 30 Years
 

Fiberglass

Properties:

  • Door Type: opaque
  • Glazing Fraction: 0.0
  • Material: fiberglass
  • Operation: swinging
  • SHGC: 0.0
  • U-Value: 0.2 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2012 (6B, 8, 6A, 2A, 4C, 3B, 2B, 4A, 5B, 7, 3C, 4B, 5C, 2C, 3A, 6C, 5A)
  • Exceeds IECC 2009 (6B, 6A, 2A, 4C, 3B, 2B, 4A, 5B, 1C, 1B, 7, 1A, 3C, 4B, 5C, 2C, 3A, 6C, 5A, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Door8.4 - 1814

Replace Swinging Entry Door:

Before-Component After-Component Cost

Steel, <=1/2-Lite Glazing

Properties:

  • Door Type: <=1/2-lite
  • Glazing Fraction: 0.29
  • Material: steel
  • Operation: swinging
  • SHGC: 0.22
  • U-Value: 0.66 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C)

Lifetime:

  • 30 Years
 

Fiberglass, <=1/2-Lite Glazing

Properties:

  • Door Type: <=1/2-lite
  • Glazing Fraction: 0.29
  • Material: fiberglass
  • Operation: swinging
  • SHGC: 0.22
  • U-Value: 0.26 Btu/h-R-ft^2

Performance Standards:

  • Exceeds Energy Star 2010
  • Exceeds IECC 2012 (8, 6B, 6A, 3B, 2A, 4C, 2B, 4A, 5B, 3C, 4B, 5C, 7, 2C, 3A, 6C, 5A)
  • Exceeds IECC 2009 (8, 6A, 3B, 2A, 4C, 1C, 2B, 4A, 5B, 1A, 3C, 4B, 5C, 1B, 7, 2C, 3A, 6C, 5A, 6B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Door7 - 1512

Replace Swinging Entry Door:

Before-Component After-Component Cost

Steel, <=1/2-Lite Glazing

Properties:

  • Door Type: <=1/2-lite
  • Glazing Fraction: 0.29
  • Material: steel
  • Operation: swinging
  • SHGC: 0.22
  • U-Value: 0.66 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C)

Lifetime:

  • 30 Years
 

Fiberglass, <=1/2-Lite Glazing

Properties:

  • Door Type: <=1/2-lite
  • Glazing Fraction: 0.29
  • Material: fiberglass
  • Operation: swinging
  • SHGC: 0.26
  • U-Value: 0.41 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1C, 1B, 1A, 3C, 2C, 3A, 2A, 3B, 2B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Door6.8 - 1511

Replace Swinging Entry Door:

Before-Component After-Component Cost

Steel, <=1/2-Lite Glazing

Properties:

  • Door Type: <=1/2-lite
  • Glazing Fraction: 0.29
  • Material: steel
  • Operation: swinging
  • SHGC: 0.22
  • U-Value: 0.66 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C)

Lifetime:

  • 30 Years
 

Fiberglass, >1/2-Lite Glazing

Properties:

  • Door Type: >1/2-lite
  • Glazing Fraction: 0.44
  • Material: fiberglass
  • Operation: swinging
  • SHGC: 0.3
  • U-Value: 0.32 Btu/h-R-ft^2

Performance Standards:

  • Meets IECC 2012 (7, 8, 5C, 5B, 4C, 5A, 6A, 6C, 6B)
  • Meets Energy Star 2010
  • Exceeds IECC 2012 (4A, 4B)
  • Exceeds IECC 2009 (7, 4B, 5C, 4A, 5B, 4C, 5A, 6A, 6C, 6B, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Door7.1 - 1512

Replace Swinging Entry Door:

Before-Component After-Component Cost

Steel, <=1/2-Lite Glazing

Properties:

  • Door Type: <=1/2-lite
  • Glazing Fraction: 0.29
  • Material: steel
  • Operation: swinging
  • SHGC: 0.22
  • U-Value: 0.66 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C)

Lifetime:

  • 30 Years
 

Steel

Properties:

  • Door Type: opaque
  • Glazing Fraction: 0.0
  • Material: steel
  • Operation: swinging
  • SHGC: 0.0
  • U-Value: 0.2 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (6B, 3B, 2A, 4C, 6A, 1A, 3C, 4B, 5C, 1B, 7, 1C, 2B, 5B, 4A, 5A, 2C, 6C, 3A, 8)
  • Exceeds IECC 2012 (6B, 3B, 4C, 2A, 6A, 4B, 3C, 5C, 7, 5B, 2B, 4A, 5A, 6C, 2C, 3A, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Door5.8 - 139.7

Replace Swinging Entry Door:

Before-Component After-Component Cost

Steel, <=1/2-Lite Glazing

Properties:

  • Door Type: <=1/2-lite
  • Glazing Fraction: 0.29
  • Material: steel
  • Operation: swinging
  • SHGC: 0.22
  • U-Value: 0.66 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C)

Lifetime:

  • 30 Years
 

Steel, <=1/2-Lite Glazing

Properties:

  • Door Type: <=1/2-lite
  • Glazing Fraction: 0.29
  • Material: steel
  • Operation: swinging
  • SHGC: 0.22
  • U-Value: 0.66 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Door5 - 118.3

Replace Swinging Entry Door:

Before-Component After-Component Cost

Steel, >1/2-Lite Glazing

Properties:

  • Door Type: >1/2-lite
  • Glazing Fraction: 0.5
  • Material: steel
  • Operation: swinging
  • SHGC: 0.43
  • U-Value: 1.21 Btu/h-R-ft^2

Lifetime:

  • 30 Years
 

Fiberglass

Properties:

  • Door Type: opaque
  • Glazing Fraction: 0.0
  • Material: fiberglass
  • Operation: swinging
  • SHGC: 0.0
  • U-Value: 0.2 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2012 (6B, 8, 6A, 2A, 4C, 3B, 2B, 4A, 5B, 7, 3C, 4B, 5C, 2C, 3A, 6C, 5A)
  • Exceeds IECC 2009 (6B, 6A, 2A, 4C, 3B, 2B, 4A, 5B, 1C, 1B, 7, 1A, 3C, 4B, 5C, 2C, 3A, 6C, 5A, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Door8.4 - 1814

Replace Swinging Entry Door:

Before-Component After-Component Cost

Steel, >1/2-Lite Glazing

Properties:

  • Door Type: >1/2-lite
  • Glazing Fraction: 0.5
  • Material: steel
  • Operation: swinging
  • SHGC: 0.43
  • U-Value: 1.21 Btu/h-R-ft^2

Lifetime:

  • 30 Years
 

Fiberglass, <=1/2-Lite Glazing

Properties:

  • Door Type: <=1/2-lite
  • Glazing Fraction: 0.29
  • Material: fiberglass
  • Operation: swinging
  • SHGC: 0.22
  • U-Value: 0.26 Btu/h-R-ft^2

Performance Standards:

  • Exceeds Energy Star 2010
  • Exceeds IECC 2012 (8, 6B, 6A, 3B, 2A, 4C, 2B, 4A, 5B, 3C, 4B, 5C, 7, 2C, 3A, 6C, 5A)
  • Exceeds IECC 2009 (8, 6A, 3B, 2A, 4C, 1C, 2B, 4A, 5B, 1A, 3C, 4B, 5C, 1B, 7, 2C, 3A, 6C, 5A, 6B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Door7 - 1512

Replace Swinging Entry Door:

Before-Component After-Component Cost

Steel, >1/2-Lite Glazing

Properties:

  • Door Type: >1/2-lite
  • Glazing Fraction: 0.5
  • Material: steel
  • Operation: swinging
  • SHGC: 0.43
  • U-Value: 1.21 Btu/h-R-ft^2

Lifetime:

  • 30 Years
 

Fiberglass, <=1/2-Lite Glazing

Properties:

  • Door Type: <=1/2-lite
  • Glazing Fraction: 0.29
  • Material: fiberglass
  • Operation: swinging
  • SHGC: 0.26
  • U-Value: 0.41 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1C, 1B, 1A, 3C, 2C, 3A, 2A, 3B, 2B)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Door6.8 - 1511

Replace Swinging Entry Door:

Before-Component After-Component Cost

Steel, >1/2-Lite Glazing

Properties:

  • Door Type: >1/2-lite
  • Glazing Fraction: 0.5
  • Material: steel
  • Operation: swinging
  • SHGC: 0.43
  • U-Value: 1.21 Btu/h-R-ft^2

Lifetime:

  • 30 Years
 

Fiberglass, >1/2-Lite Glazing

Properties:

  • Door Type: >1/2-lite
  • Glazing Fraction: 0.44
  • Material: fiberglass
  • Operation: swinging
  • SHGC: 0.3
  • U-Value: 0.32 Btu/h-R-ft^2

Performance Standards:

  • Meets IECC 2012 (7, 8, 5C, 5B, 4C, 5A, 6A, 6C, 6B)
  • Meets Energy Star 2010
  • Exceeds IECC 2012 (4A, 4B)
  • Exceeds IECC 2009 (7, 4B, 5C, 4A, 5B, 4C, 5A, 6A, 6C, 6B, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Door7.1 - 1512

Replace Swinging Entry Door:

Before-Component After-Component Cost

Steel, >1/2-Lite Glazing

Properties:

  • Door Type: >1/2-lite
  • Glazing Fraction: 0.5
  • Material: steel
  • Operation: swinging
  • SHGC: 0.43
  • U-Value: 1.21 Btu/h-R-ft^2

Lifetime:

  • 30 Years
 

Steel

Properties:

  • Door Type: opaque
  • Glazing Fraction: 0.0
  • Material: steel
  • Operation: swinging
  • SHGC: 0.0
  • U-Value: 0.2 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (6B, 3B, 2A, 4C, 6A, 1A, 3C, 4B, 5C, 1B, 7, 1C, 2B, 5B, 4A, 5A, 2C, 6C, 3A, 8)
  • Exceeds IECC 2012 (6B, 3B, 4C, 2A, 6A, 4B, 3C, 5C, 7, 5B, 2B, 4A, 5A, 6C, 2C, 3A, 8)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Door5.8 - 139.7

Replace Swinging Entry Door:

Before-Component After-Component Cost

Steel, >1/2-Lite Glazing

Properties:

  • Door Type: >1/2-lite
  • Glazing Fraction: 0.5
  • Material: steel
  • Operation: swinging
  • SHGC: 0.43
  • U-Value: 1.21 Btu/h-R-ft^2

Lifetime:

  • 30 Years
 

Steel, <=1/2-Lite Glazing

Properties:

  • Door Type: <=1/2-lite
  • Glazing Fraction: 0.29
  • Material: steel
  • Operation: swinging
  • SHGC: 0.22
  • U-Value: 0.66 Btu/h-R-ft^2

Performance Standards:

  • Exceeds IECC 2009 (1A, 1B, 1C)

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Door5 - 118.3

Replace Swinging Entry Door:

Before-Component After-Component Cost

Steel, >1/2-Lite Glazing

Properties:

  • Door Type: >1/2-lite
  • Glazing Fraction: 0.5
  • Material: steel
  • Operation: swinging
  • SHGC: 0.43
  • U-Value: 1.21 Btu/h-R-ft^2

Lifetime:

  • 30 Years
 

Steel, >1/2-Lite Glazing

Properties:

  • Door Type: >1/2-lite
  • Glazing Fraction: 0.5
  • Material: steel
  • Operation: swinging
  • SHGC: 0.43
  • U-Value: 1.21 Btu/h-R-ft^2

Lifetime:

  • 30 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Door6.8 - 1511

Version: v3.1.0