Retrofit Measures for Wood Stud

Here you will find the data for Wood Stud measures available in the National Residential Efficiency Measures Database. Each measure consists of a before-component, an after-component, and the estimated cost to implement the measure. The measures are listed alphabetically based upon the name of the before-component. Where multiple costs are indicated they must be combined to obtain total measure cost (e.g., fixed ($) and normalized ($/sf) costs).

Cost Drivers

There are many factors that influence the ultimate cost of Wood Stud measures. The application of the average measure costs displayed below to any particular home is discouraged. Examples of the kinds of issues that can influence the cost of Wood Stud measures include:
  • Prevailing local wages
  • Drive time
  • Local code requirements
  • Presence/condition/type of existing insulation
  • Existing construction and materials
  • Moisture issues present
  • Condition of existing electrical system
  • Presence of hazardous materials

Viewing 26 Wood Stud Measure(s) of 26

Insulate with Loose Fill:

Before-Component After-Component Cost

R-7 Fiberglass Batt, 2x4, 16 in o.c.

Properties:

  • Cavity Depth: 3.5 in
  • Cavity Install Grade: 1
  • Cavity Insulation Nominal R-value: 7.0 h-ft^2-R/Btu
  • Cavity Insulation Type: fiberglass batt
  • Framing Factor: 0.25 frac
  • Framing Spacing: 16.0 in
  • Stud Size: 2x4 in x in

Lifetime:

  • 999 Years
 

R-13 Cellulose, 2x4, 16 in o.c.

Properties:

  • Cavity Depth: 3.5 in
  • Cavity Install Grade: 1
  • Cavity Insulation Nominal R-value: 13.0 h-ft^2-R/Btu
  • Cavity Insulation Type: cellulose
  • Framing Factor: 0.25 frac
  • Framing Spacing: 16.0 in
  • Stud Size: 2x4 in x in

Performance Standards:

  • Meets IECC 2009 (1A, 3C, 4B, 2C, 3A, 2A, 3B, 2B, 4A, 1C, 1B)
  • Meets IECC 2012 (2B, 1C, 1B, 2A, 1A, 2C)

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Exterior Wall0.5 - 1.10.83

Insulate with Loose Fill through Brick:

Before-Component After-Component Cost

R-7 Fiberglass Batt, 2x4, 16 in o.c.

Properties:

  • Cavity Depth: 3.5 in
  • Cavity Install Grade: 1
  • Cavity Insulation Nominal R-value: 7.0 h-ft^2-R/Btu
  • Cavity Insulation Type: fiberglass batt
  • Framing Factor: 0.25 frac
  • Framing Spacing: 16.0 in
  • Stud Size: 2x4 in x in

Lifetime:

  • 999 Years
 

R-13 Cellulose, 2x4, 16 in o.c.

Properties:

  • Cavity Depth: 3.5 in
  • Cavity Install Grade: 1
  • Cavity Insulation Nominal R-value: 13.0 h-ft^2-R/Btu
  • Cavity Insulation Type: cellulose
  • Framing Factor: 0.25 frac
  • Framing Spacing: 16.0 in
  • Stud Size: 2x4 in x in

Performance Standards:

  • Meets IECC 2009 (1A, 3C, 4B, 2C, 3A, 2A, 3B, 2B, 4A, 1C, 1B)
  • Meets IECC 2012 (2B, 1C, 1B, 2A, 1A, 2C)

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Exterior Wall0.77 - 1.71.3

Insulate with Loose Fill through Brick:

Before-Component After-Component Cost

R-7 Fiberglass Batt, 2x4, 16 in o.c.

Properties:

  • Cavity Depth: 3.5 in
  • Cavity Install Grade: 1
  • Cavity Insulation Nominal R-value: 7.0 h-ft^2-R/Btu
  • Cavity Insulation Type: fiberglass batt
  • Framing Factor: 0.25 frac
  • Framing Spacing: 16.0 in
  • Stud Size: 2x4 in x in

Lifetime:

  • 999 Years
 

R-13 Cellulose, 2x4, 16 in o.c., Grade 2

Properties:

  • Cavity Depth: 3.5 in
  • Cavity Install Grade: 2
  • Cavity Insulation Nominal R-value: 13.0 h-ft^2-R/Btu
  • Cavity Insulation Type: cellulose
  • Framing Factor: 0.25 frac
  • Framing Spacing: 16.0 in
  • Stud Size: 2x4 in x in

Performance Standards:

  • Meets IECC 2009 (3B, 2A, 2C, 3A, 1A, 3C, 4B, 1B, 1C, 2B, 4A)
  • Meets IECC 2012 (2A, 1C, 2B, 2C, 1A, 1B)

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Exterior Wall0.75 - 1.61.3

Insulate with Loose Fill:

Before-Component After-Component Cost

R-7 Fiberglass Batt, 2x4, 16 in o.c.

Properties:

  • Cavity Depth: 3.5 in
  • Cavity Install Grade: 1
  • Cavity Insulation Nominal R-value: 7.0 h-ft^2-R/Btu
  • Cavity Insulation Type: fiberglass batt
  • Framing Factor: 0.25 frac
  • Framing Spacing: 16.0 in
  • Stud Size: 2x4 in x in

Lifetime:

  • 999 Years
 

R-13 Cellulose, 2x4, 16 in o.c., Grade 2

Properties:

  • Cavity Depth: 3.5 in
  • Cavity Install Grade: 2
  • Cavity Insulation Nominal R-value: 13.0 h-ft^2-R/Btu
  • Cavity Insulation Type: cellulose
  • Framing Factor: 0.25 frac
  • Framing Spacing: 16.0 in
  • Stud Size: 2x4 in x in

Performance Standards:

  • Meets IECC 2009 (3B, 2A, 2C, 3A, 1A, 3C, 4B, 1B, 1C, 2B, 4A)
  • Meets IECC 2012 (2A, 1C, 2B, 2C, 1A, 1B)

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Exterior Wall0.48 - 1.10.81

Insulate with Loose Fill:

Before-Component After-Component Cost

R-7 Fiberglass Batt, 2x4, 16 in o.c.

Properties:

  • Cavity Depth: 3.5 in
  • Cavity Install Grade: 1
  • Cavity Insulation Nominal R-value: 7.0 h-ft^2-R/Btu
  • Cavity Insulation Type: fiberglass batt
  • Framing Factor: 0.25 frac
  • Framing Spacing: 16.0 in
  • Stud Size: 2x4 in x in

Lifetime:

  • 999 Years
 

R-13 Cellulose, 2x4, 16 in o.c., Grade 3

Properties:

  • Cavity Depth: 3.5 in
  • Cavity Install Grade: 3
  • Cavity Insulation Nominal R-value: 13.0 h-ft^2-R/Btu
  • Cavity Insulation Type: cellulose
  • Framing Factor: 0.25 frac
  • Framing Spacing: 16.0 in
  • Stud Size: 2x4 in x in

Performance Standards:

  • Meets IECC 2012 (2C, 1A, 1B, 2A, 1C, 2B)
  • Meets IECC 2009 (3B, 2A, 1C, 2B, 4A, 1A, 3C, 4B, 1B, 2C, 3A)

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Exterior Wall0.47 - 10.79

Insulate with Loose Fill through Brick:

Before-Component After-Component Cost

R-7 Fiberglass Batt, 2x4, 16 in o.c.

Properties:

  • Cavity Depth: 3.5 in
  • Cavity Install Grade: 1
  • Cavity Insulation Nominal R-value: 7.0 h-ft^2-R/Btu
  • Cavity Insulation Type: fiberglass batt
  • Framing Factor: 0.25 frac
  • Framing Spacing: 16.0 in
  • Stud Size: 2x4 in x in

Lifetime:

  • 999 Years
 

R-13 Cellulose, 2x4, 16 in o.c., Grade 3

Properties:

  • Cavity Depth: 3.5 in
  • Cavity Install Grade: 3
  • Cavity Insulation Nominal R-value: 13.0 h-ft^2-R/Btu
  • Cavity Insulation Type: cellulose
  • Framing Factor: 0.25 frac
  • Framing Spacing: 16.0 in
  • Stud Size: 2x4 in x in

Performance Standards:

  • Meets IECC 2012 (2C, 1A, 1B, 2A, 1C, 2B)
  • Meets IECC 2009 (3B, 2A, 1C, 2B, 4A, 1A, 3C, 4B, 1B, 2C, 3A)

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Exterior Wall0.73 - 1.61.2

Insulate with Loose Fill through Brick:

Before-Component After-Component Cost

R-7 Fiberglass Batt, 2x4, 16 in o.c.

Properties:

  • Cavity Depth: 3.5 in
  • Cavity Install Grade: 1
  • Cavity Insulation Nominal R-value: 7.0 h-ft^2-R/Btu
  • Cavity Insulation Type: fiberglass batt
  • Framing Factor: 0.25 frac
  • Framing Spacing: 16.0 in
  • Stud Size: 2x4 in x in

Lifetime:

  • 999 Years
 

R-13 Fiberglass, 2x4, 16 in o.c.

Properties:

  • Cavity Depth: 3.5 in
  • Cavity Install Grade: 1
  • Cavity Insulation Nominal R-value: 13.0 h-ft^2-R/Btu
  • Cavity Insulation Type: fiberglass
  • Framing Factor: 0.25 frac
  • Framing Spacing: 16.0 in
  • Stud Size: 2x4 in x in

Performance Standards:

  • Meets IECC 2012 (2B, 1C, 1B, 2A, 1A, 2C)
  • Meets IECC 2009 (2B, 4A, 1C, 1B, 1A, 3C, 4B, 2C, 3A, 2A, 3B)

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Exterior Wall0.64 - 1.41.1

Insulate with Loose Fill:

Before-Component After-Component Cost

R-7 Fiberglass Batt, 2x4, 16 in o.c.

Properties:

  • Cavity Depth: 3.5 in
  • Cavity Install Grade: 1
  • Cavity Insulation Nominal R-value: 7.0 h-ft^2-R/Btu
  • Cavity Insulation Type: fiberglass batt
  • Framing Factor: 0.25 frac
  • Framing Spacing: 16.0 in
  • Stud Size: 2x4 in x in

Lifetime:

  • 999 Years
 

R-13 Fiberglass, 2x4, 16 in o.c.

Properties:

  • Cavity Depth: 3.5 in
  • Cavity Install Grade: 1
  • Cavity Insulation Nominal R-value: 13.0 h-ft^2-R/Btu
  • Cavity Insulation Type: fiberglass
  • Framing Factor: 0.25 frac
  • Framing Spacing: 16.0 in
  • Stud Size: 2x4 in x in

Performance Standards:

  • Meets IECC 2012 (2B, 1C, 1B, 2A, 1A, 2C)
  • Meets IECC 2009 (2B, 4A, 1C, 1B, 1A, 3C, 4B, 2C, 3A, 2A, 3B)

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Exterior Wall0.37 - 0.840.65

Insulate with Open Cell Spray Foam:

Before-Component After-Component Cost

R-7 Fiberglass Batt, 2x4, 16 in o.c.

Properties:

  • Cavity Depth: 3.5 in
  • Cavity Install Grade: 1
  • Cavity Insulation Nominal R-value: 7.0 h-ft^2-R/Btu
  • Cavity Insulation Type: fiberglass batt
  • Framing Factor: 0.25 frac
  • Framing Spacing: 16.0 in
  • Stud Size: 2x4 in x in

Lifetime:

  • 999 Years
 

R-13 Open Cell Spray Foam, 2x4, 16 in o.c.

Properties:

  • Cavity Depth: 3.5 in
  • Cavity Install Grade: 1
  • Cavity Insulation Nominal R-value: 13.0 h-ft^2-R/Btu
  • Cavity Insulation Type: open cell spray foam
  • Framing Factor: 0.25 frac
  • Framing Spacing: 16.0 in
  • Stud Size: 2x4 in x in

Performance Standards:

  • Meets IECC 2012 (2B, 1C, 1B, 2A, 1A, 2C)
  • Meets IECC 2009 (1A, 4B, 3C, 2C, 3A, 2A, 3B, 4A, 2B, 1C, 1B)

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Exterior Wall0.49 - 1.31.2

Insulate with Closed Cell Spray Foam:

Before-Component After-Component Cost

R-7 Fiberglass Batt, 2x4, 16 in o.c.

Properties:

  • Cavity Depth: 3.5 in
  • Cavity Install Grade: 1
  • Cavity Insulation Nominal R-value: 7.0 h-ft^2-R/Btu
  • Cavity Insulation Type: fiberglass batt
  • Framing Factor: 0.25 frac
  • Framing Spacing: 16.0 in
  • Stud Size: 2x4 in x in

Lifetime:

  • 999 Years
 

R-23 Closed Cell Spray Foam, 2x4, 16 in o.c.

Properties:

  • Cavity Depth: 3.5 in
  • Cavity Install Grade: 1
  • Cavity Insulation Nominal R-value: 23.0 h-ft^2-R/Btu
  • Cavity Insulation Type: closed cell spray foam
  • Framing Factor: 0.25 frac
  • Framing Spacing: 16.0 in
  • Stud Size: 2x4 in x in

Performance Standards:

  • Exceeds IECC 2009 (6B, 3B, 2A, 4C, 6A, 1A, 3C, 4B, 5C, 7, 1B, 1C, 2B, 5B, 4A, 5A, 6C, 2C, 3A, 8)
  • Exceeds IECC 2012 (3B, 2A, 4C, 2C, 3A, 1A, 3C, 4B, 5C, 1B, 1C, 2B, 5B, 4A, 5A)

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Exterior Wall1.5 - 3.32.5

Insulate with Loose Fill:

Before-Component After-Component Cost

Uninsulated, 2x4, 16 in o.c.

Properties:

  • Cavity Depth: 3.5 in
  • Cavity Install Grade:
  • Cavity Insulation Nominal R-value: h-ft^2-R/Btu
  • Cavity Insulation Type:
  • Framing Factor: 0.25 frac
  • Framing Spacing: 16.0 in
  • Stud Size: 2x4 in x in

Lifetime:

  • 999 Years
 

R-13 Cellulose, 2x4, 16 in o.c.

Properties:

  • Cavity Depth: 3.5 in
  • Cavity Install Grade: 1
  • Cavity Insulation Nominal R-value: 13.0 h-ft^2-R/Btu
  • Cavity Insulation Type: cellulose
  • Framing Factor: 0.25 frac
  • Framing Spacing: 16.0 in
  • Stud Size: 2x4 in x in

Performance Standards:

  • Meets IECC 2009 (1A, 3C, 4B, 2C, 3A, 2A, 3B, 2B, 4A, 1C, 1B)
  • Meets IECC 2012 (2B, 1C, 1B, 2A, 1A, 2C)

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Exterior Wall1.4 - 2.92.2

Insulate with Loose Fill through Brick:

Before-Component After-Component Cost

Uninsulated, 2x4, 16 in o.c.

Properties:

  • Cavity Depth: 3.5 in
  • Cavity Install Grade:
  • Cavity Insulation Nominal R-value: h-ft^2-R/Btu
  • Cavity Insulation Type:
  • Framing Factor: 0.25 frac
  • Framing Spacing: 16.0 in
  • Stud Size: 2x4 in x in

Lifetime:

  • 999 Years
 

R-13 Cellulose, 2x4, 16 in o.c.

Properties:

  • Cavity Depth: 3.5 in
  • Cavity Install Grade: 1
  • Cavity Insulation Nominal R-value: 13.0 h-ft^2-R/Btu
  • Cavity Insulation Type: cellulose
  • Framing Factor: 0.25 frac
  • Framing Spacing: 16.0 in
  • Stud Size: 2x4 in x in

Performance Standards:

  • Meets IECC 2009 (1A, 3C, 4B, 2C, 3A, 2A, 3B, 2B, 4A, 1C, 1B)
  • Meets IECC 2012 (2B, 1C, 1B, 2A, 1A, 2C)

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Exterior Wall2 - 4.13.2

Insulate with Loose Fill:

Before-Component After-Component Cost

Uninsulated, 2x4, 16 in o.c.

Properties:

  • Cavity Depth: 3.5 in
  • Cavity Install Grade:
  • Cavity Insulation Nominal R-value: h-ft^2-R/Btu
  • Cavity Insulation Type:
  • Framing Factor: 0.25 frac
  • Framing Spacing: 16.0 in
  • Stud Size: 2x4 in x in

Lifetime:

  • 999 Years
 

R-13 Cellulose, 2x4, 16 in o.c., Grade 2

Properties:

  • Cavity Depth: 3.5 in
  • Cavity Install Grade: 2
  • Cavity Insulation Nominal R-value: 13.0 h-ft^2-R/Btu
  • Cavity Insulation Type: cellulose
  • Framing Factor: 0.25 frac
  • Framing Spacing: 16.0 in
  • Stud Size: 2x4 in x in

Performance Standards:

  • Meets IECC 2009 (3B, 2A, 2C, 3A, 1A, 3C, 4B, 1B, 1C, 2B, 4A)
  • Meets IECC 2012 (2A, 1C, 2B, 2C, 1A, 1B)

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Exterior Wall1.4 - 2.82.2

Insulate with Loose Fill through Brick:

Before-Component After-Component Cost

Uninsulated, 2x4, 16 in o.c.

Properties:

  • Cavity Depth: 3.5 in
  • Cavity Install Grade:
  • Cavity Insulation Nominal R-value: h-ft^2-R/Btu
  • Cavity Insulation Type:
  • Framing Factor: 0.25 frac
  • Framing Spacing: 16.0 in
  • Stud Size: 2x4 in x in

Lifetime:

  • 999 Years
 

R-13 Cellulose, 2x4, 16 in o.c., Grade 2

Properties:

  • Cavity Depth: 3.5 in
  • Cavity Install Grade: 2
  • Cavity Insulation Nominal R-value: 13.0 h-ft^2-R/Btu
  • Cavity Insulation Type: cellulose
  • Framing Factor: 0.25 frac
  • Framing Spacing: 16.0 in
  • Stud Size: 2x4 in x in

Performance Standards:

  • Meets IECC 2009 (3B, 2A, 2C, 3A, 1A, 3C, 4B, 1B, 1C, 2B, 4A)
  • Meets IECC 2012 (2A, 1C, 2B, 2C, 1A, 1B)

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Exterior Wall1.9 - 4.13.1

Insulate with Loose Fill:

Before-Component After-Component Cost

Uninsulated, 2x4, 16 in o.c.

Properties:

  • Cavity Depth: 3.5 in
  • Cavity Install Grade:
  • Cavity Insulation Nominal R-value: h-ft^2-R/Btu
  • Cavity Insulation Type:
  • Framing Factor: 0.25 frac
  • Framing Spacing: 16.0 in
  • Stud Size: 2x4 in x in

Lifetime:

  • 999 Years
 

R-13 Cellulose, 2x4, 16 in o.c., Grade 3

Properties:

  • Cavity Depth: 3.5 in
  • Cavity Install Grade: 3
  • Cavity Insulation Nominal R-value: 13.0 h-ft^2-R/Btu
  • Cavity Insulation Type: cellulose
  • Framing Factor: 0.25 frac
  • Framing Spacing: 16.0 in
  • Stud Size: 2x4 in x in

Performance Standards:

  • Meets IECC 2012 (2C, 1A, 1B, 2A, 1C, 2B)
  • Meets IECC 2009 (3B, 2A, 1C, 2B, 4A, 1A, 3C, 4B, 1B, 2C, 3A)

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Exterior Wall1.3 - 2.82.2

Insulate with Loose Fill through Brick:

Before-Component After-Component Cost

Uninsulated, 2x4, 16 in o.c.

Properties:

  • Cavity Depth: 3.5 in
  • Cavity Install Grade:
  • Cavity Insulation Nominal R-value: h-ft^2-R/Btu
  • Cavity Insulation Type:
  • Framing Factor: 0.25 frac
  • Framing Spacing: 16.0 in
  • Stud Size: 2x4 in x in

Lifetime:

  • 999 Years
 

R-13 Cellulose, 2x4, 16 in o.c., Grade 3

Properties:

  • Cavity Depth: 3.5 in
  • Cavity Install Grade: 3
  • Cavity Insulation Nominal R-value: 13.0 h-ft^2-R/Btu
  • Cavity Insulation Type: cellulose
  • Framing Factor: 0.25 frac
  • Framing Spacing: 16.0 in
  • Stud Size: 2x4 in x in

Performance Standards:

  • Meets IECC 2012 (2C, 1A, 1B, 2A, 1C, 2B)
  • Meets IECC 2009 (3B, 2A, 1C, 2B, 4A, 1A, 3C, 4B, 1B, 2C, 3A)

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Exterior Wall1.9 - 4.13.1

Insulate with Loose Fill:

Before-Component After-Component Cost

Uninsulated, 2x4, 16 in o.c.

Properties:

  • Cavity Depth: 3.5 in
  • Cavity Install Grade:
  • Cavity Insulation Nominal R-value: h-ft^2-R/Btu
  • Cavity Insulation Type:
  • Framing Factor: 0.25 frac
  • Framing Spacing: 16.0 in
  • Stud Size: 2x4 in x in

Lifetime:

  • 999 Years
 

R-13 Fiberglass, 2x4, 16 in o.c.

Properties:

  • Cavity Depth: 3.5 in
  • Cavity Install Grade: 1
  • Cavity Insulation Nominal R-value: 13.0 h-ft^2-R/Btu
  • Cavity Insulation Type: fiberglass
  • Framing Factor: 0.25 frac
  • Framing Spacing: 16.0 in
  • Stud Size: 2x4 in x in

Performance Standards:

  • Meets IECC 2012 (2B, 1C, 1B, 2A, 1A, 2C)
  • Meets IECC 2009 (2B, 4A, 1C, 1B, 1A, 3C, 4B, 2C, 3A, 2A, 3B)

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Exterior Wall1.2 - 2.62

Insulate with Loose Fill through Brick:

Before-Component After-Component Cost

Uninsulated, 2x4, 16 in o.c.

Properties:

  • Cavity Depth: 3.5 in
  • Cavity Install Grade:
  • Cavity Insulation Nominal R-value: h-ft^2-R/Btu
  • Cavity Insulation Type:
  • Framing Factor: 0.25 frac
  • Framing Spacing: 16.0 in
  • Stud Size: 2x4 in x in

Lifetime:

  • 999 Years
 

R-13 Fiberglass, 2x4, 16 in o.c.

Properties:

  • Cavity Depth: 3.5 in
  • Cavity Install Grade: 1
  • Cavity Insulation Nominal R-value: 13.0 h-ft^2-R/Btu
  • Cavity Insulation Type: fiberglass
  • Framing Factor: 0.25 frac
  • Framing Spacing: 16.0 in
  • Stud Size: 2x4 in x in

Performance Standards:

  • Meets IECC 2012 (2B, 1C, 1B, 2A, 1A, 2C)
  • Meets IECC 2009 (2B, 4A, 1C, 1B, 1A, 3C, 4B, 2C, 3A, 2A, 3B)

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Exterior Wall1.8 - 3.93

Insulate with Open Cell Spray Foam:

Before-Component After-Component Cost

Uninsulated, 2x4, 16 in o.c.

Properties:

  • Cavity Depth: 3.5 in
  • Cavity Install Grade:
  • Cavity Insulation Nominal R-value: h-ft^2-R/Btu
  • Cavity Insulation Type:
  • Framing Factor: 0.25 frac
  • Framing Spacing: 16.0 in
  • Stud Size: 2x4 in x in

Lifetime:

  • 999 Years
 

R-13 Open Cell Spray Foam, 2x4, 16 in o.c.

Properties:

  • Cavity Depth: 3.5 in
  • Cavity Install Grade: 1
  • Cavity Insulation Nominal R-value: 13.0 h-ft^2-R/Btu
  • Cavity Insulation Type: open cell spray foam
  • Framing Factor: 0.25 frac
  • Framing Spacing: 16.0 in
  • Stud Size: 2x4 in x in

Performance Standards:

  • Meets IECC 2012 (2B, 1C, 1B, 2A, 1A, 2C)
  • Meets IECC 2009 (1A, 4B, 3C, 2C, 3A, 2A, 3B, 4A, 2B, 1C, 1B)

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Exterior Wall1.2 - 2.82.4

Insulate with Closed Cell Spray Foam:

Before-Component After-Component Cost

Uninsulated, 2x4, 16 in o.c.

Properties:

  • Cavity Depth: 3.5 in
  • Cavity Install Grade:
  • Cavity Insulation Nominal R-value: h-ft^2-R/Btu
  • Cavity Insulation Type:
  • Framing Factor: 0.25 frac
  • Framing Spacing: 16.0 in
  • Stud Size: 2x4 in x in

Lifetime:

  • 999 Years
 

R-23 Closed Cell Spray Foam, 2x4, 16 in o.c.

Properties:

  • Cavity Depth: 3.5 in
  • Cavity Install Grade: 1
  • Cavity Insulation Nominal R-value: 23.0 h-ft^2-R/Btu
  • Cavity Insulation Type: closed cell spray foam
  • Framing Factor: 0.25 frac
  • Framing Spacing: 16.0 in
  • Stud Size: 2x4 in x in

Performance Standards:

  • Exceeds IECC 2009 (6B, 3B, 2A, 4C, 6A, 1A, 3C, 4B, 5C, 7, 1B, 1C, 2B, 5B, 4A, 5A, 6C, 2C, 3A, 8)
  • Exceeds IECC 2012 (3B, 2A, 4C, 2C, 3A, 1A, 3C, 4B, 5C, 1B, 1C, 2B, 5B, 4A, 5A)

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Exterior Wall2.2 - 4.83.7

Insulate with Loose Fill:

Before-Component After-Component Cost

Uninsulated, 2x6, 24 in o.c.

Properties:

  • Cavity Depth: 5.5 in
  • Cavity Install Grade:
  • Cavity Insulation Nominal R-value: h-ft^2-R/Btu
  • Cavity Insulation Type:
  • Framing Factor: 0.22 frac
  • Framing Spacing: 24.0 in
  • Stud Size: 2x6 in x in

Lifetime:

  • 999 Years
 

R-19 Cellulose, 2x6, 24 in o.c.

Properties:

  • Cavity Depth: 5.5 in
  • Cavity Install Grade: 1
  • Cavity Insulation Nominal R-value: 19.0 h-ft^2-R/Btu
  • Cavity Insulation Type: cellulose
  • Framing Factor: 0.22 frac
  • Framing Spacing: 24.0 in
  • Stud Size: 2x6 in x in

Performance Standards:

  • Exceeds IECC 2012 (1C, 2B, 1A, 1B, 2A, 2C)
  • Exceeds IECC 2009 (1B, 2C, 3A, 3B, 2A, 1C, 2B, 4A, 1A, 3C, 4B)

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Exterior Wall1.9 - 43.1

Insulate with Loose Fill through Brick:

Before-Component After-Component Cost

Uninsulated, 2x6, 24 in o.c.

Properties:

  • Cavity Depth: 5.5 in
  • Cavity Install Grade:
  • Cavity Insulation Nominal R-value: h-ft^2-R/Btu
  • Cavity Insulation Type:
  • Framing Factor: 0.22 frac
  • Framing Spacing: 24.0 in
  • Stud Size: 2x6 in x in

Lifetime:

  • 999 Years
 

R-19 Cellulose, 2x6, 24 in o.c.

Properties:

  • Cavity Depth: 5.5 in
  • Cavity Install Grade: 1
  • Cavity Insulation Nominal R-value: 19.0 h-ft^2-R/Btu
  • Cavity Insulation Type: cellulose
  • Framing Factor: 0.22 frac
  • Framing Spacing: 24.0 in
  • Stud Size: 2x6 in x in

Performance Standards:

  • Exceeds IECC 2012 (1C, 2B, 1A, 1B, 2A, 2C)
  • Exceeds IECC 2009 (1B, 2C, 3A, 3B, 2A, 1C, 2B, 4A, 1A, 3C, 4B)

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Exterior Wall2.7 - 5.84.5

Insulate with Loose Fill:

Before-Component After-Component Cost

Uninsulated, 2x6, 24 in o.c.

Properties:

  • Cavity Depth: 5.5 in
  • Cavity Install Grade:
  • Cavity Insulation Nominal R-value: h-ft^2-R/Btu
  • Cavity Insulation Type:
  • Framing Factor: 0.22 frac
  • Framing Spacing: 24.0 in
  • Stud Size: 2x6 in x in

Lifetime:

  • 999 Years
 

R-19 Fiberglass, 2x6, 24 in o.c.

Properties:

  • Cavity Depth: 5.5 in
  • Cavity Install Grade: 1
  • Cavity Insulation Nominal R-value: 19.0 h-ft^2-R/Btu
  • Cavity Insulation Type: fiberglass
  • Framing Factor: 0.22 frac
  • Framing Spacing: 24.0 in
  • Stud Size: 2x6 in x in

Performance Standards:

  • Exceeds IECC 2009 (1C, 2A, 3B, 2C, 3A, 1B, 1A, 3C, 4B, 2B, 4A)
  • Exceeds IECC 2012 (1B, 1A, 2B, 2C, 1C, 2A)

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Exterior Wall1.8 - 3.82.9

Insulate with Loose Fill through Brick:

Before-Component After-Component Cost

Uninsulated, 2x6, 24 in o.c.

Properties:

  • Cavity Depth: 5.5 in
  • Cavity Install Grade:
  • Cavity Insulation Nominal R-value: h-ft^2-R/Btu
  • Cavity Insulation Type:
  • Framing Factor: 0.22 frac
  • Framing Spacing: 24.0 in
  • Stud Size: 2x6 in x in

Lifetime:

  • 999 Years
 

R-19 Fiberglass, 2x6, 24 in o.c.

Properties:

  • Cavity Depth: 5.5 in
  • Cavity Install Grade: 1
  • Cavity Insulation Nominal R-value: 19.0 h-ft^2-R/Btu
  • Cavity Insulation Type: fiberglass
  • Framing Factor: 0.22 frac
  • Framing Spacing: 24.0 in
  • Stud Size: 2x6 in x in

Performance Standards:

  • Exceeds IECC 2009 (1C, 2A, 3B, 2C, 3A, 1B, 1A, 3C, 4B, 2B, 4A)
  • Exceeds IECC 2012 (1B, 1A, 2B, 2C, 1C, 2A)

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Exterior Wall2.6 - 5.64.3

Insulate with Open Cell Spray Foam:

Before-Component After-Component Cost

Uninsulated, 2x6, 24 in o.c.

Properties:

  • Cavity Depth: 5.5 in
  • Cavity Install Grade:
  • Cavity Insulation Nominal R-value: h-ft^2-R/Btu
  • Cavity Insulation Type:
  • Framing Factor: 0.22 frac
  • Framing Spacing: 24.0 in
  • Stud Size: 2x6 in x in

Lifetime:

  • 999 Years
 

R-20 Open Cell Spray Foam, 2x6, 24 in o.c.

Properties:

  • Cavity Depth: 5.5 in
  • Cavity Install Grade: 1
  • Cavity Insulation Nominal R-value: 20.0 h-ft^2-R/Btu
  • Cavity Insulation Type: open cell spray foam
  • Framing Factor: 0.22 frac
  • Framing Spacing: 24.0 in
  • Stud Size: 2x6 in x in

Performance Standards:

  • Exceeds IECC 2009 (4A, 2B, 3B, 2A, 3A, 2C, 1A, 4B, 3C, 1B, 1C)
  • Exceeds IECC 2012 (1A, 1B, 1C, 2C, 2B, 2A)
  • Meets IECC 2009 (5C, 6B, 5B, 6A, 6C, 5A, 4C)
  • Meets IECC 2012 (4A, 5B, 3B, 5A, 4C, 3A, 5C, 3C, 4B)

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Exterior Wall2.1 - 4.84

Insulate with Closed Cell Spray Foam:

Before-Component After-Component Cost

Uninsulated, 2x6, 24 in o.c.

Properties:

  • Cavity Depth: 5.5 in
  • Cavity Install Grade:
  • Cavity Insulation Nominal R-value: h-ft^2-R/Btu
  • Cavity Insulation Type:
  • Framing Factor: 0.22 frac
  • Framing Spacing: 24.0 in
  • Stud Size: 2x6 in x in

Lifetime:

  • 999 Years
 

R-36 Closed Cell Spray Foam, 2x6, 24 in o.c.

Properties:

  • Cavity Depth: 5.5 in
  • Cavity Install Grade: 1
  • Cavity Insulation Nominal R-value: 36.0 h-ft^2-R/Btu
  • Cavity Insulation Type: closed cell spray foam
  • Framing Factor: 0.22 frac
  • Framing Spacing: 24.0 in
  • Stud Size: 2x6 in x in

Performance Standards:

  • Exceeds IECC 2012 (3B, 2A, 4C, 1B, 2C, 3A, 5A, 1C, 2B, 5B, 4A, 1A, 3C, 4B, 5C)
  • Exceeds IECC 2009 (6A, 4C, 8, 6B, 6C, 2C, 3A, 5A, 1C, 2B, 5B, 4A, 1A, 3C, 4B, 5C, 7, 1B, 3B, 2A)

Lifetime:

  • 999 Years
 

Measure Cost

UnitsRangeAverage
$/ft^2 Exterior Wall3.7 - 8.16.2

Version: v3.1.0